Is it safe to use a CO2 fire extinguisher on a high voltage transformer?

Encyclopedia
Field: Encyclopedia
0
China

Using a carbon dioxide (CO₂) fire extinguisher on a high-voltage transformer is generally safe, but there are important considerations to keep in mind. Here are the key points regarding the safety and precautions:

Safety

Non-Conductive: Carbon dioxide (CO₂) is an inert gas and does not conduct electricity. Therefore, using a CO₂ fire extinguisher to extinguish electrical fires does not increase the risk of electric shock, which is one of its main advantages.

No Residue: CO₂ leaves no residue after extinguishing a fire, preventing secondary contamination or damage to electrical equipment.

Cooling Effect: CO₂ fire extinguishers work by reducing oxygen concentration and providing a cooling effect, which helps to quickly control the fire.

Precautions

Ventilation: CO₂ gas can cause suffocation in enclosed spaces. Ensure there is adequate ventilation when using a CO₂ fire extinguisher to prevent personnel from inhaling excessive amounts of CO₂.

Personal Protective Equipment (PPE): When operating a CO₂ fire extinguisher, wear appropriate personal protective equipment, such as safety glasses and gloves, to prevent frostbite and eye injuries.

Stay Away from Live Parts: Although CO₂ is non-conductive, try to stay away from live electrical parts while extinguishing the fire to avoid accidental contact and potential electric shock.

Identify the Source of the Fire: Ensure that you identify and extinguish the source of the fire, not just the surface flames. Thoroughly extinguishing the source can prevent the fire from reigniting.

Professional Guidance: When dealing with high-voltage transformer fires, it is best to have professional electrical engineers or firefighters present to ensure safe operation.

Alternative Options

Dry Powder Fire Extinguisher: Dry powder fire extinguishers are also effective for electrical fires, but they can leave residue that requires subsequent cleaning.

Dry Ice Fire Extinguisher: Dry ice fire extinguishers use solid CO₂, which is also non-conductive, but use them carefully to avoid frostbite.

Automatic Fire Suppression Systems: For large high-voltage transformers, consider installing automatic fire suppression systems, such as gas-based systems (e.g., FM-200), which can automatically activate to quickly extinguish fires in their early stages.

Summary

Using a carbon dioxide fire extinguisher on a high-voltage transformer is generally safe, but it is crucial to follow the above precautions to ensure the safety of the operators. If possible, seek professional assistance when dealing with high-voltage electrical fires.

Give a tip and encourage the author!

Recommended

Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Reclosing Charge Time: Why Does Reclosing Require Charging? What Effects Does Charging Time Have?
1. Function and Significance of Reclosing ChargingReclosing is a protective measure in power systems. After faults such as short circuits or circuit overloads occur, the system isolates the faulty circuit and then restores normal operation through reclosing. The function of reclosing is to ensure continuous operation of the power system, improving its reliability and safety.Before performing reclosing, the circuit breaker must be charged. For high-voltage circuit breakers, the charging time is g
12/15/2025
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.