Cut Sheet: What is it? (Example Cut Sheets Included)

Electrical4u
Field: Basic Electrical
0
China
what is a cut sheet

What is a Cut Sheet?

A cut sheet (also known as a spec sheet or specification sheet) is an equipment information sheet that provides and describes the specifications and/or features of a piece of equipment. These are common in the electrical industry for equipment such as motors, circuit breakers, transformers, and other electrical equipment.

Any commercial electrical job typically has to have all material or equipment approved by the electrical engineers, owners, or both. A cut sheet gives you sizes, ratings, capacities, colors—and any other information potentially needed for an installation.

Many cut sheets or spec sheets include a photograph and lists of parts of the equipment as well as other equipment model numbers and the features of their alternate models.

The alternate equipment model number and features in the cut sheet are very useful for comparison purposes to help you make sure you’ve got the right piece of equipment for your project.

Cut Sheet Examples

The cut sheet is essentially a report that is used during the installation of electrical equipment. Hence, a cut sheet of any electrical equipment provides sizes, ratings, capacities of the equipment, etc.

For example, a cut sheet or data-sheet of an MCB (Miniature Circuit Breaker) provides important specifications like its rated current, poles description, its application, trip mechanism, network type, network frequency, braking capacity, rated operating voltage, etc.

Let’s look at an example of this.

Example 1: Miniature Circuit Breaker (MCB)



MCB
Miniature Circuit Breaker (MCB)



Main Specifications:

The main specifications of a Miniature Circuit Breaker (MCB) are listed in the below cut sheet (which you can see basically reads like a data-sheet).

Product Type Miniature Circuit Breaker (MCB)
Product Application Distribution Network
Poles Description 1P
Trip Mechanism Thermal-magnetic
Line Rated Current 1.5 A (250 C)
Network Type AC/DC
Network Frequency 50/60 Hz
Breaking Capacity 5 kA, 240 V AC
10 kA, 120 V AC
10 kA, 60 V DC
Rated Operating Voltage 240 V AC
120 V AC
60 V DC


Example 2: Liquid-filled transformer



Transformer
Oil-Filled Transformer



The main specifications and advanced features of an Oil-filled Transformer are listed in the example cut-sheet below.

Main Specifications:


Product Type Oil-filled transformer
Liquid fluids type Mineral oil, Silicone transformer oil, Less flammable seed oil
Primary Voltage 2.4 kV to 69 kV
Secondary Voltage 600 V to 35 kV
kVA Rating 225 kVA to 20,000 kVA
Applications Commercial and Industrial applications


Advanced Features:

  1. High-frequency standards

  2. Sealed Tank construction

  3. Copper or Aluminum windings

  4. Self-cooled Overload capabilities

  5. Fan-cooled Overload capabilities

  6. The higher standard than conventional Dry Type Transformers

  7. Less flammable fluids available for indoor applications

  8. Ideal for a wide variety of commercial and industrial applications

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!

Recommended

Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
01/30/2026
Neutral point grounding operation mode for 110kV~220kV power grid transformers
The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
01/29/2026
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
01/29/2026
HECI GCB for Generators – Fast SF6 Circuit Breaker
1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
01/06/2026
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.