What is a Deaerating Heater and How Does It Work?

Master Electrician
Field: Basic Electrical
0
China

WechatIMG1754.jpeg

A deaerating heater, also known as a deaerator, is a device that removes dissolved gases, mainly oxygen, and carbon dioxide, from boiler feedwater. Dissolved gases can cause corrosion and damage to the boiler and its components, as well as reduce the efficiency of the steam cycle. Therefore, deaerating heaters are essential for boiler water treatment and protection.

    WechatIMG1755.png


Deaerating heaters can be classified into two types: tray type and spray type. Both types use steam to heat the feedwater and strip off the dissolved gases. The steam also acts as a source of oxygen-scavenging chemicals, such as hydrazine or sodium sulfite, that react with the remaining traces of oxygen in the feedwater.

Tray Type Deaerating Heater

    WechatIMG1756.png


A tray-type deaerating heater consists of a vertical cylindrical vessel with a series of perforated trays inside. The feedwater enters from the top and is sprayed over the trays, creating a thin film of water that flows downward. The steam enters from the bottom and rises upward through the trays, heating the water and removing the dissolved gases. The deaerated water collects at the bottom of the vessel and is pumped to the boiler. The vented gases escape from the top of the vessel.

The advantages of a tray-type deaerating heater are:

  • It can handle a wide range of feedwater flow rates and temperatures.

  • It can achieve very low levels of dissolved oxygen (less than 5 ppb) and carbon dioxide (less than 1 ppm).

  • It has a large storage capacity for feedwater, which helps to maintain constant pressure and temperature in the boiler.

The disadvantages of a tray-type deaerating heater are:

  • It requires a large amount of steam for deaeration, which reduces the thermal efficiency of the cycle.

  • It has a high capital cost and maintenance cost due to the complexity and size of the vessel and trays.

  • It is susceptible to scaling and fouling on the trays, which reduces heat transfer and deaeration efficiency.

Spray Type Deaerating Heater


    WechatIMG1757.png


A spray-type deaerating heater consists of a horizontal cylindrical vessel with a spray nozzle inside. The feedwater enters from one end and is sprayed into a stream of steam that enters from the other end. The steam heats the water and removes the dissolved gases. The deaerated water collects at the bottom of the vessel and is pumped to the boiler. The vented gases escape from the top of the vessel.

The advantages of a spray-type deaerating heater are:

  • It requires less steam for deaeration than a tray-type deaerating heater, which improves the thermal efficiency of the cycle.

  • It has a lower capital cost and maintenance cost than a tray-type deaerating heater due to the simplicity and compactness of the vessel and nozzle.

  • It is less prone to scaling and fouling than a tray-type deaerating heater due to the high velocity and turbulence of the water and steam.

The disadvantages of a spray-type deaerating heater are:

  • It cannot handle very high or very low feedwater flow rates and temperatures without affecting the deaeration efficiency.

  • It cannot achieve as low levels of dissolved oxygen (about 10 ppb) and carbon dioxide (about 5 ppm) as a tray-type deaerating heater.

  • It has a smaller storage capacity for feedwater than a tray-type deaerating heater, which makes it more sensitive to pressure and temperature fluctuations in the boiler.

Factors Affecting Deaeration Efficiency

The efficiency of deaeration depends on several factors, such as:

  • The temperature and pressure of the feedwater and steam. Higher temperature and lower pressure increase the solubility of gases in water, making it harder to remove them. Therefore, it is important to maintain an optimal temperature difference between the feedwater and steam (usually about 5°C) and an optimal pressure in the deaerating heater (usually about 0.2 bar) and an optimal temperature difference between the feedwater and steam (usually about 5°C).

  • The amount and quality of steam used for deaeration. The steam should be saturated and free of non-condensable gases. The steam flow rate should be sufficient to provide the required heat and mass transfer for deaeration. The steam flow rate should also be regulated to maintain constant pressure in the deaerating heater.

  • The design and operation of the deaerating heater. The deaerating heater should have enough surface area and contact time for the feedwater and steam to interact. The feedwater should be sprayed or distributed evenly over the trays or nozzles to create a thin film of water. The deaerating heater should also have a vent condenser to recover the heat and water from the vented gases.

Benefits of Deaerating Heaters

Deaerating heaters provide several benefits for boiler systems, such as:

  • They prevent corrosion and pitting of boiler tubes, drums, and other components by removing dissolved oxygen and carbon dioxide from the feedwater.

  • They reduce the chemical oxygen scavenger consumption and cost by minimizing the residual oxygen in the feedwater.

  • They improve the thermal efficiency of the boiler by preheating the feedwater to near saturation temperature, reducing heat loss and fuel consumption.

  • They increase the boiler’s reliability and availability by reducing the risk of boiler failures and downtime due to corrosion and scaling.

Conclusion

Deaerating heaters are vital devices for boiler water treatment and protection. They remove dissolved gases from the feedwater using steam as a heating and purging agent. They can be classified into tray type and spray type, depending on their design and configuration. They operate based on the principles of Henry’s Law, Dalton’s Law, and mass and heat transfer. They require optimal conditions of temperature, pressure, and steam flow rate to achieve high deaeration efficiency. They provide several benefits for boiler systems, such as preventing corrosion, reducing chemical consumption, improving thermal efficiency, and increasing reliability.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
Why Regular Transformer Maintenance Matters: 5 Serious Consequences of Neglecting It
I. Allowable TemperatureWhen a transformer is in operation, its windings and iron core generate copper loss and iron loss. These losses are converted into heat energy, causing the temperature of the transformer's iron core and windings to rise. If the temperature exceeds the allowable value for a long time, the insulation will gradually lose its mechanical elasticity and age.The temperature of each part of the transformer during operation is different: the winding temperature is the highest, fol
Rockwell
09/12/2025
How to Implement Condition-Based Maintenance for Power Transformers? A Complete 4-Step Process Analysis
1. Definition of Condition-Based MaintenanceCondition-based maintenance refers to a maintenance method where decisions on whether and how to perform maintenance are determined based on the real-time operating status and health condition of equipment. It has no fixed maintenance methods or schedules. The prerequisite for condition-based maintenance is the establishment of equipment parameters and the comprehensive analysis of various operational information of the equipment, so as to make reasona
Noah
09/12/2025
Can't choose a dry-type transformer? Get expert advice – free.
Traction Rectifier TransformersRated capacity: 800 to 4400 kVA; Voltage class: 10 kV and 35 kV; Rectifier pulse number: 12-pulse and 24-pulse. Compared with 12-pulse rectifier circuits, 24-pulse rectifier circuits can reduce the harmonic pollution of the power grid by 50%, and no filtering equipment is needed at this location. It is suitable for power supply systems of urban subways and rail transit.Excitation Rectifier TransformersRated capacity: 315 to 3000 × 3 kVA; Voltage class: 10 kV, 13.8
Vziman
09/12/2025
High harmonics? Your transformer may be overheating and aging fast.
This report is based on the analysis of one-day power quality monitoring data of your company's distribution system. The data shows that there is significant three-phase current harmonic distortion in the system (with a high total harmonic distortion of current, THDi). In accordance with international standards (IEC/IEEE), harmonic currents at this level have posed substantial risks to the safe, reliable, and economical operation of the power supply transformer, mainly manifested in additional h
Leon
09/12/2025
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.