Types of Electrostatic Precipitator

Electrical4u
Field: Basic Electrical
0
China

WechatIMG1880.jpeg

The world is slowly but continually moving towards a greener future. There is much excitement among engineers about the prospects of greener technology. However, coal-based power plants are still the primary source of electrical power in many countries. Baring few countries in the world like Norway or Iceland, all other countries depend heavily on coal to produce the bulk of the electricity demand. Coal necessitates that we use some technology to reduce the pollution that is caused by such power plants. Electrostatic precipitator does exactly that. Electrostatic precipitator uses an electrostatic field to remove pollution causing particles from a flowing gas such as air. They are one of the best filtration devices and can remove fine particulate matter such as dust and smoke from the air stream. They have now become mandatory in a thermal power plant.

The particles flowing in a stream of air are charged by ionization and then made to flow between charged electrodes. The particles and the electrodes have opposite charge. This causes the pollutant particles to get attracted towards the electrode plates, and they are collected there. The clean air moves out of the electrostatic precipitator. The pollutants are collected separately in a hopper by hammering the plates.

There are different types of the electrostatic precipitator, and we will study about each of them one by one:

Dry Electrostatic Precipitator

It collects the pollutants, also known as ash or cement, in a dry state hence known by that name. The precipitator collects the dust particles from a stream of air. The particles are first ionized so that they become electrically charged. Later they are made to flow through oppositely charged electrodes where the particles are collected by the electrodes. The dust particles are collected by hammering the electrodes. They are collected in a hopper where they can be extracted out. They are used for removing dirt from flue gases in thermal power plants. They are also used to clean the air in ventilation and air condition systems.

Wet Electrostatic Precipitator

Wet electrostatic precipitators are used to remove wet particles such as resin, oil, paint, tar, acid or anything that is not dry in the conventional sense. They are used in industrial applications where the potential for explosion is high. They are used for particles with high resistivity or high corrosive nature. The particles in a wet electrostatic precipitator are given an electric charge when they pass through a corona. In other words, the particles are ionized, just like in Dry ESPs. The difference lies in the collector (electrodes). The collectors are continuously sprayed with a liquid, generally water. Thus the particles collected from a sludge. The sludge is collected and treated separately. They can be used for particles which cannot be separated by dry ESPs. They have higher efficiency than dry ESPs. The continuous or intermittent washing with a liquid eliminates the entertainment of particles due to rapping which dry ESPs are subject to.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!

Recommended

Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
01/30/2026
Neutral point grounding operation mode for 110kV~220kV power grid transformers
The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
01/29/2026
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
01/29/2026
HECI GCB for Generators – Fast SF6 Circuit Breaker
1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c