Types of Overhead Conductor

Electrical4u
Field: Basic Electrical
0
China

What Are The Types Of Overhead Conductor

Conductor is a physical medium to carry electrical energy form one place to other. It is an important component of overhead and underground electrical transmission and distribution systems. The choice of conductor depends on the cost and efficiency. An ideal conductor has following features.

  • It has maximum electrical conductivity.

  • It has high tensile strength so that it can withstand mechanical stresses.

  • It has least specific gravity i.e. weight/unit volume.

  • It has least cost without sacrificing other factors.

Types of Overhead Conductor

In early days copper ‘Cu’ conductors was used for transmitting energy in stranded hard drawn form to increase tensile strength. But now it has been replaced by aluminum ‘Al’ due to following reasons:

  • It has lesser cost than copper.

  • It offers larger diameter for same amount of current which reduces corona.

Corona: is ionization of air due to higher voltage (usually voltage above critical voltage) which causes violet light around the conductor and hissing sound. It also produces ozone gas therefore it is undesirable condition.
Aluminium also has some disadvantages over copper i.e.

  • It has lesser conductivity.

  • It has larger diameter which increase surface area to air pressure thus it swings more in air than copper so larger cross arms required which increases the cost.

  • It has lesser tensile strength ultimately larger sag.

  • It has lesser specific gravity (2.71gm/cc) than copper (8.9 gm/cc) cc = cubic centimeter.

Due to lower tensile strength aluminium is used with some other materials or its alloys

AAC (All Aluminium Conductor)

  • It has lesser strength and more sag per span length than any other category.

  • Therefore, it is used for lesser span i.e. it is applicable at distribution level.

  • It has slightly better conductivity at lower voltages than ACSR i.e. at distribution level

  • Cost of ACSR is equal to AAC.

ACAR (Aluminium Conductor, Aluminium Reinforce)

  • It is cheaper than AAAC but pro to corrosion.

  • It is most expansive.

AAAC (All Aluminium Alloy Conductor)

aaac conductor

  • It has same construction as AAC except the alloy.

  • Its strength is equal to ACSR but due to absence of steel it is light in weight.

  • The presence of formation of alloy makes it expensive.

  • Due to stronger tensile strength than AAC, it is used for longer spans.

  • It can be used in distribution level i.e. river crossing.

  • It has lesser sag than AAC.

  • The difference between ACSR and AAAC is the weight. Being lighter in weight, it is used in transmission and sub-transmission where lighter support structure is required such as mountains, swamps etc.

ACSR (Aluminium Conductor Steel Reinforced)

acsr conductor

  • It is used for longer spans keeping sag minimum.

  • It may consist of 7 or 19 strands of steel surrounding by aluminium strands concentrically. The number of strands are shown by x/y/z, where ‘x’ is number of aluminium strands, ‘y’ is number of steel strands and ‘z’ is diameter of each strand.

  • Strands provide flexibility, prevent breakage and minimize skin effect.

  • The number of strands depends on the application, they may be 7, 19, 37, 61, 91 or more.

  • If the Al and St strands are separated by a filler such as paper then this kind of ACSR is used in EHV lines and called expanded ACSR.

  • Expanded ACSR has larger diameter and hence lower corona losses.

IACS (International Annealed Copper Stand)

  • It is 100% pure conductor and it is standard for reference.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!

Recommended

Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
01/30/2026
Neutral point grounding operation mode for 110kV~220kV power grid transformers
The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
01/29/2026
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
01/29/2026
HECI GCB for Generators – Fast SF6 Circuit Breaker
1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
01/06/2026
Related Products
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.