10kV class S (B) H15 series amorphous alloy distribution transformer

  • 10kV class S (B) H15 series amorphous alloy distribution transformer

Key attributes

Brand ROCKWILL
Model NO. 10kV class S (B) H15 series amorphous alloy distribution transformer
Rated voltage 10kV
Rated frequency 50/60Hz
Rated capacity 1250kVA
Series S (B) H

Product descriptions from the supplier

Description

Product Description

The 10kV class S(B) H15 series amorphous alloy distribution transformer represents a leap forward in energy-efficient power distribution technology. Engineered with a core of advanced amorphous metal, this transformer series is designed to achieve ultra-low no-load losses, significantly reducing electricity waste and operational costs. Ideal for utility grids, commercial complexes, and industrial plants, the S(B) H15 series offers exceptional reliability and a rapid return on investment by minimizing the total cost of ownership over its entire lifecycle. It sets a new standard for eco-friendly and economically viable electrical infrastructure.

Key Features

  • Features an H15 grade amorphous alloy core that reduces no-load losses by 60-80% compared to conventional silicon steel transformers, translating directly into lower electricity costs.

  • Ultra-low no-load losses ensure the lowest total cost of ownership over its entire service life, offering an excellent return on investment despite a slightly higher initial capital outlay.

  • Drastically reduced energy consumption leads to a lower carbon footprint. As a dry-type transformer, it is oil-free, flame-retardant, and explosion-proof, making it safer and more environmentally friendly.

  • The amorphous core is inherently resilient to mechanical stress and offers strong short-circuit resistance. An optimized magnetic circuit design ensures quiet operation below standard limits, suitable for noise-sensitive areas.

  • Designed and manufactured in compliance with international standards (IEC, IEEE) and relevant Chinese National Standards (GB), guaranteeing global applicability, reliability, and high quality.

Product model

  • S: Three-phase

  • (B): Low-voltage Foil Winding

  • H: Amorphous Alloy

  • 15: Performance Level Code

  • M: Hermetically Sealed

  • First □: Rated Capacity (kVA)

  • Second □: Rated High Voltage

Performance Parameters - Technical Parameters of S (B) H15-M Series Oil-Immersed Distribution Transformer

Rated Capacity

Voltage Combination and Tap Range

Connection Group

No-load Loss (W)

Load Loss at 120℃ (W)

Short-circuit Impedance %

No-load Current %

Outline Dimensions

(Length * Width * Height mm)

Total Weight (kg)

High Voltage kV

Tap Range %

Low Voltage kV

30

6

6.3

6.6

10

10.5

11

±5±2×2.5


0.4

Yyno

Dyn11

33

600

4.0

 

1.7

1100 * 690 * 1090

630

50

43

870

1.3

1190 * 750 * 1140

710

63

50

1040

1.2

1250 * 750 * 1160

750

80

60

1250

1.1

1290 * 750 * 1160

810

100

75

1500

1

1260 * 800 * 1190

870

125

85

1800

0.9

1320 * 870 * 1220

940

160

100

2200

0.7

1370 * 810 * 1220

1050

200

120

2600

0.7

1410 * 800 * 1320

1140

250

140

3050

0.7

1490 * 810 * 1360

1290

315

170

3650

0.5

1520 * 790 * 1430

1500

400

200

4300

0.5

1670 * 820 * 1510

1710

500

240

5150

0.5

1650 * 910 * 1450

1960

630

320

6200


0.3

1830 * 920 * 1440

2250

800

380

7500

0.3

1910 * 950 * 1500

2730

1000                     

450

10300

0.3

2000 * 1100 * 1490

3300

1250

530

12000

0.2

2100 * 1100 * 1580

3560

1600

630

14500

0.2

2120 * 1240 * 1560

3830

Note: the above parameters are only for typical values, and can be customized according to customer requirements.

Implementation criteria: GB1094.1~2-1996, GB1094.3-2003, GB1094.5-2008, GB/T6451-2008

Conditions of use

  • No more than 1000m indoor or outdoor

  • The highest ambient air temperature is +40℃, the highest daily average temperature is +30℃.

  • Maximum annual average temperature +20℃ minimum temperature -25℃

  • According to user requirements, transformers can be operated under special conditions.

 

 

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.