• 5kVA-1000kVA Solar isolation transformers
5kVA-1000kVA Solar isolation transformers
discuss personally
Model
SG-200kVA
SG-100kVA
SG-1000kVA
Basic info
Brand ROCKWILL
Model NO. 5kVA-1000kVA Solar isolation transformers
Rated frequency 50/60Hz
Rated capacity 200kVA
Series SG
Product Detail

Product Overview

The transformer is the main component of various power supplies and electrical equipment, the transformer is composed of cylindrical windings and laminated iron cores, and the iron cores are stacked with new high-quality high-silicon silicon steel sheets and fully mitered joints. The company adopts advanced production technology, with imported Spanish winding machine and a full set of vacuum pressure impregnation equipment; The winding adopts the whole column winding method; Vacuum impregnation of the transformer to make the insulation grade of the transformer reach class F or H. The output and input voltages of the transformer can be designed according to customer needs.

Product features:

  • Scientific and reasonable design, the voltage change rate is controlled within 1~1.5%.

  • It is made of high-quality new silicon steel sheet, which can effectively reduce iron loss and improve efficiency.

  • It is made of high-quality wire rod with high temperature resistance, which minimizes its own loss and greatly improves the efficacy.

  • The use of H-class insulation, high temperature resistant insulation materials, improve the high voltage strength, insulation grade, and prolong the service life.

  • High efficiency design, up to more than 98%.

  • Patented design, beautiful, novel, high power density, small size, high space utilization.

  • The product chassis is divided into stainless steel and iron boxes, and there are inlet and outlet holes outside the box shell for the installation of power lines. If necessary, voltmeter, ammeter, temperature control alarm system, etc. can be added according to user requirements.

Technical data:

Product Advantages:

  • 100% full power.

  • Imported silicon steel sheet Low iron loss High magnetic induction strength.

  • LED display Clear and intuitive display.

  • Adopt high temperature resistant DM0.2 insulating paper Insulating sleeve 155°C.

  • Pure copper coil Wire two-layer insulating paint Low wire loss Not easy to oxidize.

  • The box has a built-in cooling fan,Intelligent control of temperature control meter .

  • The chassis is painted with the latest technology, and the rainproof design is IP65 certified.

Material description of transformer:

  • Iron core:Adopts new high-quality high-silicon silicon steel sheet, the main material is 0.35 thick H18, H14, H12, Z11 high-quality silicon steel sheet, we select the most suitable material according to customer requirements and use conditions, so that the transformer performance design to achieve the best. (The conventional material is a new high-quality silicon steel sheet).

  • The wire:Rod is made of PEW, UEW, EIW, SEIW, FEAI enameled wire and glass wire coated wire, and the temperature resistance level is F class (155 °C), H class (180 °C), HC class (200 °C), C class (220 °C). (The conventional temperature resistance level is H class 180°C).

  • Insulating material:High temperature resistant insulating paper is used as insulating material, which has multiple properties of high temperature insulation, flame retardant and moisture resistance.

  • Terminal block :The terminal block adopts the terminal block for small power, which is beautiful in appearance and has excellent voltage resistance, temperature resistance and flame retardant performance. The high power adopts high-quality copper bar.

  •  Iron feet:Mainly use CNC bending cold plate

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!