• 145kV  Dead Tank SF6  Circuit Breaker
145kV Dead Tank SF6 Circuit Breaker
discuss personally
Model
LW-145
Basic info
Brand ROCKWILL
Model NO. 145kV Dead Tank SF6 Circuit Breaker
Rated voltage 145kV
Rated frequency 50/60Hz
Series LW
Product Detail

Description:

The 145kV dead tank SF6 circuit breaker is a high-reliability high-voltage device designed to ensure stable operation of power systems. It adopts a dead tank structure, with live parts sealed in a metal casing filled with SF6 gas, ensuring rapid arc extinction and efficient fault current interruption to safeguard grid safety. The low-center-of-gravity design gives it strong seismic resistance, adapting to harsh environments such as extreme climates. The equipment integrates bushings and current transformers to support multi-functional control such as measurement and protection. With long mechanical/electrical life and a sealed structure, maintenance frequency is significantly reduced. Equipped with anti-misoperation interlocking devices, it ensures the safety of personnel and equipment. Widely used in power, metallurgy, transportation and other fields, it performs excellently in medium and high voltage scenarios.

Product Advantages:

  • The spring operating mechanism of the circuit breaker is safe and stable, maintenance-free, and highly reliable, and meets the requirements of oil-free and gas-free operating mechanism.
  • Self-energy-compressed combined arc extinguisher.
  • The equipment is shipped after the lightning impact test, which eliminates the hidden danger of insulation discharge caused by production and assembly, and ensures the stable and reliable product quality.
  • The quality of the insulators is stable and reliable.
  • High parameterization: The technical parameters of the products are all of the highest standards in the industry.
  • The domestic first-class design team, suppliers and internal control system ensure the safety, stability and reliability of the products, and the products and inspection standards manufactured in the factory have been recognized by the State Grid and the Southern Power Grid Supervision.
  • Using advanced R&D tools such as finite element analysis software, functional analysis, whole-process quality characteristic chain, size chain analysis, potential failure mode and effect analysis (FEMA), etc., the modular design is realized on the basis of ensuring the safety, stability and reliability of product performance.
  • Earthquake resistance of magnitude 9.

Product features:

  • Spring operating mechanism, reliable performance;
  • Excellent breaking performance
  • E2-M2-C2 circuit breaker, electrical life 20 times, mechanical life 10000 times.
  • Strong rated flow capacity;
  • Excellent insulation level, small local discharge;
  • Excellent corrosion resistance;
  • Advanced design tools;
  • Strict process assembly and quality control.

 Use of the environment:

  • Installation location: indoor/outdoor;
  • Ambient air temperature :
  • Maximum temperature: +55°C;
  • Minimum temperature: -40°C; Maximum daily temperature difference: 32 K;
  • Altitude: ≦3000m;
  • Sunshine intensity (noon on sunny day): 1000 W/㎡;
  • Pollution level: III./IV. grade;
  • Icing thickness: 10mm/20mm;
  • Wind speed/wind pressure: 34m/s (equivalent to 700Pa on the surface of the cylinder);
  • Humidity: average daily relative humidity: ≦95%; Monthly average relative humidity: ≦90%;
  • Earthquake resistance: nine degrees;
  • Horizontal acceleration: 0.3g;
  • Vertical acceleration: 0.15g.

Use of the product:

In densely populated areas, in harmony with existing buildings, in important and critical substations, in confined space substation expansions, in flexible retrofits and replacements, in places with heavy loads, for economical and reliable energy management, in power stations, etc.
LW58A-126/145 SF6 canister circuit breaker is one of the new generation of switchgear of Shanghai Siyuan High Voltage Switchgear Co., Ltd., which has won the trust of users with its compact design and reliable performance.
 
Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!