• 6/10kV Three - phase dry - type grounding/earthing transformer
  • 6/10kV Three - phase dry - type grounding/earthing transformer
6/10kV Three - phase dry - type grounding/earthing transformer
discuss personally
Model
DKSC-10/1000
DKSC-6/800
Basic info
Brand ROCKWILL
Model NO. 6/10kV Three - phase dry - type grounding/earthing transformer
Rated voltage 10kV
Rated frequency 50/60Hz
Rated capacity 1000kVA
Series DKSC
Product Detail

Description

Designed for grounding protection in medium-voltage power grids, the 6/10kV three-phase dry-type grounding transformer adopts epoxy resin vacuum casting thin-insulation technology. Both high and low-voltage windings are wound with copper foils, ensuring partial discharge values below 10pC. Thanks to the foil winding structure, it features large interlayer capacitance and linear initial voltage distribution, delivering outstanding lightning impulse withstand capability. The windings have consistent reactance heights and balanced ampere-turns, with near-zero axial short-circuit force, ensuring excellent short-circuit resistance.

With insulation classes F/H, the transformer operates safely at 155℃/180℃ long-term. Its core uses mineral oxide-insulated cold-rolled silicon steel sheets, achieving low no-load loss and noise. Moisture-proof, flame-retardant, and self-extinguishing, it suits urban distribution networks, industrial facilities, etc. Covering capacities up to 10,000kVA, it establishes a stable neutral grounding system for ≤35kV systems.

Feature

  •  High Lightning Impulse Withstand Capability:Due to the high - and low - voltage windings all being wound with copper strips (foils), the interlayer voltage is low, the capacitance is large, and the initial voltage distribution of the foil - type winding is close to linear. Therefore, its lightning impulse withstand capability is strong.

  •  High Short - Circuit Withstand Capability:Because the reactance heights of the high - and low - voltage windings are the same, there is no helix angle phenomenon, and the ampere - turn balance between the coils is achieved. The axial force on the high - and low - voltage windings caused by short - circuit is almost zero. Therefore, its short - circuit withstand capability is strong.

  • Good Anti - Cracking Performance:The dry - type transformer adopts the epoxy resin “thin insulation (1 - 3mm) technology”, which meets the requirements of occasions with low temperature, high temperature, and a large temperature variation range, and meets the anti - cracking requirements after long - term operation. It solves the cracking problem that is difficult to solve with the “thick insulation (6mm) technology”, providing reliable technical guarantee for dry - type transformers.

  • Strong Overload Capacity:If the load losses of transformers with the same capacity are equal, the area of the copper foil will be increased correspondingly compared with the copper conductor. After the volume is increased, the dosage of the filling resin is increased correspondingly. Therefore, the heat capacity of the winding is large, and the short - term overload capacity of the transformer is strong.

  • Good Flame - Retardant Performance:The epoxy resin vacuum casting process is adopted without environmental pollution, which is beneficial to environmental protection. The transformer has the characteristics of maintenance - free, moisture - proof, resistance to damp - heat, flame - retardant, and self - extinguishing, and is suitable for various environments and harsh conditions.

  • Low Loss and Low Noise:The iron core usually adopts high - quality cold - rolled silicon steel sheets insulated with mineral oxides. Through advanced processing technology, the loss level and no - load current are reduced to the minimum, and a very low noise level is achieved. At the same time, the assembled iron core is coated with class F resin paint on its surface to prevent dust, corrosion, smoke, and rust.

  •  High Temperature Resistance Grade:The epoxy resin dry - type transformer belongs to class F or class H insulation, and can operate safely at a high temperature of 155℃ or 180℃ for a long time. With the same capacity, it has a small volume and light weight, which can save installation costs, etc.

  •  Relevant Technical Specifications:Capacity ≤ 10000kVA; Voltage ≤ 35kV;  Insulation grade: class F or H

Main technical parameter

Outline Dimensions Diagram

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec