Key attributes

Brand ROCKWILL
Model NO. 33kv 1250kVA Three Phase Power Distribution Compact Transformer Substation
Rated voltage 33kV
Rated frequency 50/60Hz
Series YBM

Product descriptions from the supplier

Description

Descripton

35kV Combined type transformer substation is a kind of complete set product integrating voltage switch equipment and transformer with LV distribution equipment. It is usually applied to civic architectures, Residential districts, mid-size and small-size factories, mine and oil fields, used as transformation and distribution equipment, with characteristics of strong completeness, compact structure, high Reliability, low on-site workload, short installation period, movability, etc. In addition, its color and exterior can be changed appropriately to adapt to the surroundings and beautify the environment, It really is the ideal successor of current urban and rural civil engineering transformer substation, and also is a new type complete set equipment for urban network construction and reformation.

Features

  • This transformer substation is made up of HV switch compartment, LV switch compartment, relay protection compartment and transformer compartment. Enclosures of HV switch compartment, LV switch compartment and relay protection compartment can be made of aluminum alloy plate, steel plate of composite plate. Aluminum alloy plate is anodic oxidation treated to strengthen its corrosion stability. Steel plate and steel structured parts are all phosphating treated, and the composite plate is
  • Featured with vivid appearance, heat insulation and fire retardation. The transformer compartment is arranged with safe guard protecting net but not enclosed enclosure, which not only guarantees better thermal diffusivity, but also is able to insure person and equipment against accident.
  • HV switch compartment The HV switch compartment can be mounted with JYNI-35, KYNI0-35 switchgear or 35KV load switch. Aerial cable type is available formounting 35KV inletand outlet wire.
  • LV switch compartment:When it is 10KV at LV side, the LV switch compartment can be mounted with XGN2-10, KZNI-12 and KYNI-12 switchgear, HXGNII-10F, HXGN26-10(F) Ring main unit. When it is 0.4KV at LV side, the LV switch compartment (no preparation of LV switchgear in consideration of space saving) can be mounted with DW15T series, ME series, M series and F series frame type circuit breaker as well as DZ20 series, CM series, H series and S series molded case air circuit breaker.
  • Power-off protection compartment The power-off protection compartment is mounted with AC panel, DC panel, signal panel, protection pandel, motion control panel(RTU), carrier wave machine panel or optical fiber termination set.
  • Refer to the diagram for plan layout and vertical plane layout of transformer substation of 35KV.

Main Technical Specifications

Environmental conditions

  •  Altitude: ≤ 1000m;
  • Ambient temperature: +40C -25C ;
  • Relative humidity: Daily average ≤ 95%, monthly average ≤ 90%;
  • Abnormal severe vibration or impact;
  • Environment for installation: Indoors, no fire or explosion danger, no corrosive gas or dust, no sharp impact.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.