• Single-phase pad-mounted transformers with protective functions
Single-phase pad-mounted transformers with protective functions
discuss personally
Model
ZGS-20
Basic info
Brand Vziman
Model NO. Single-phase pad-mounted transformers with protective functions
Rated frequency 50/60Hz
Primary voltage 2400-19920 V
Secondary voltage 120-600 V
Capacity range 10-167 kVA
Series ZSG
Product Detail

Descripton:

The Completely Self-Protection (CSP) single-phase pad-mounted transformer is designed with the core objective of achieving excellent performance. It integrates a directly connected primary surge arrester, a MagneX arc extinguishing chamber, or a secondary circuit breaker with a built-in primary voltage fuse. There is no need to install additional independent protective equipment, which significantly reduces the installation cost.

The power range of this series of transformers covers 10 - 75 kVA. When equipped with a MagneX arc extinguishing chamber, the power range can be expanded to 10 - 167 kVA, and its performance fully meets or even exceeds relevant standards such as ANSI and NEMA.

In addition, the CSP transformer supports two types of filling media. It can be filled with standard electrical-grade mineral insulating oil or FR3 liquid with excellent fire resistance, flexibly adapting to different usage scenarios.

Features:

  • Equipped with an internal overcurrent device and a surge arrester, it can achieve efficient overvoltage protection without the need for external independent protective components. For secondary faults and overloads, it can provide dual reliable protection through a secondary circuit breaker with weak links or an optional MagneX arc extinguishing chamber.

  • It supports the free choice of two filling media: FR3 fireproof insulating oil, which greatly enhances the fire safety level; or standard electrical-grade mineral oil to meet regular usage requirements. The product performance comprehensively surpasses industry standards and performs excellently in terms of ANSI specifications, NEMA standards, and DOE energy efficiency requirements.

  • The core and coils are deeply optimized in design. Aiming to achieve high reliability and a low failure rate, it offers two materials, grain-oriented steel and amorphous steel, to adapt to different performance needs. Both the high-voltage and low-voltage bushing terminals are tinned, making them compatible with aluminum and copper conductors to ensure stable and reliable electrical connections.

  • The exterior design takes into account both functionality and aesthetics, offering two style options: the MaxiShrub style equipped with an ANSI Type-1 front panel, or the Shrubline style with an ANSI Type-2 front panel. Both adopt a low-profile design and can better blend into the surrounding environment.

Technical Parameters:

Specifications:

  • Meet or exceeds ANSI, NEMA and DOE2016 standards

  • IEEE standards C57.12.00, C57.12.38, C57.12.28, C57.12.35, C57.12.90, C57. 91 and C57.154

  • NEMA standards, NEMA TR 1 (R2000)

  • Department of Energy Efficiency Standard, 10 CFR Part 431

  • Tank coating exceeds IEEE Std C57.12.28-2005 and C57.12.29-2005 standards (stainless steel units only)

  • Full compliance with IEEE Std C57.12.28-2005 standard enclosure integrity requirements

  • FR3 fluid or electrical grade mineral oil

  • Cores and coils designed for high reliability and low field failure rates: Available in grain-oriented electrical or amorphous steel

  • The transformer shall be designed in accordance with this specification and shall have an Average Winding Rise (AWR) of one of the following:

  • 55 °C, 55/65 °C, 65 °C

  • The applicable AWR rating shall be specified on the inquiry

  • The transformer shall be designed in accordance with this specification and shall have one of the following kVA ratings:

  • 10, 15, 25, 37.5, 50, 75, 100, 167

  • The applicable kVA rating shall be specified on the inquiry

  • Quality System ISO 9001 certified

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!