• Three-phase 10kW Small Diesel Generator Sets
  • Three-phase 10kW Small Diesel Generator Sets
  • Three-phase 10kW Small Diesel Generator Sets
  • Three-phase 10kW Small Diesel Generator Sets
Three-phase 10kW Small Diesel Generator Sets
discuss personally
Model
DMD12000LE/3
Basic info
Brand Wone
Model NO. Three-phase 10kW Small Diesel Generator Sets
Phases Single-phase
Engine Max Output Power 16/3600 kW/rpm
Generator Rated Power 10kW
Generator Rated Voltage 400/230V
Generator Capacity 40L
Series Small diesel generator set
Product Detail

Description:

  • Large muffler, dynamic balance shaft, special design of low-noise unit, shell and frame with shock absorption function.

  • Large capacity fuel tank to ensure long-term work.

  • Non-fuse circuit breaker provides overload protection, capacitive voltage regulator to ensure stable voltage output.

  • Durable four-wheel dragging base structure, easy to move.

Parameter:

image.png

Feature:

The two - cylinder air - cooled engine - compact structure

  • It is a four - stroke, direct - injection, air - cooled engine with a well - designed transmission mechanism. It features light weight, small volume, and low failure rate. The high - precision fuel injection pump enables full combustion of fuel and greater fuel efficiency.

企业微信截图_17343149434085.png

Humanized brake universal wheels - convenient for movement

  • When using the brake universal foot wheels, they can be temporarily fixed, and they can be switched to the rotation mode at any time when pushed. Its structure allows for a horizontal 360 - degree rotation. It rotates flexibly, making it convenient for outdoor construction movement. The wheel material is made of nylon, which is wear - resistant and has a long service life.

企业微信截图_17343151503802.png

High - strength open - frame structure - convenient for maintenance

  • It uses high - quality metal pipes and American - style design. The cross - frame is integrally welded, with a high safety factor and good heat dissipation performance.

  • It is convenient for maintenance and suitable for various engineering construction applications.

OTC automatic welding

  • The frame is more solid, the joints are less likely to break, and it is safer and more reassuring.

企业微信截图_17343152931359.png

The all - copper - wire - wound damping motor has high reliability

  • The damping motor has good waveform, small distortion, strong overload capacity, and high reliability. It is equipped with an AVR automatic voltage regulator to stabilize the generator's output voltage and automatically change the excitation current size.

企业微信截图_17343154107109.png

Multifunctional digital display voltmeter - one - key display

  • The generator's voltage, frequency, and usage duration are displayed with one key, allowing you to grasp the usage status of the generator at any time.

  • It is equipped with over - current and over - load protection devices, which can independently protect the generator.

企业微信截图_17343154998737.png



Know your supplier
Wone
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!