40.5(72.5)kV Hybrid Type HV Gas-Insulated Switchgear(GIS)

  • 40.5(72.5)kV Hybrid Type HV Gas-Insulated Switchgear(GIS)

Key attributes

Brand Wone Store
Model NO. 40.5(72.5)kV Hybrid GIS
Rated voltage 72.5kV
Rated normal current 4000A
Rated frequency 50/60Hz
Rated short circuit breaking current 40kA
Series ZHW58A-40.5(72.5)

Product descriptions from the supplier

Description

Product introduction:

ZHW58A series was originally designed to meet the needs of power construction and hybrid product development, and its main application scenario is to meet the needs of 35-500KV substation expansion; At present, ZHW58A-40.5/72.5 products have reached the leading level at home and abroad in terms of technical advancement and quality reliability.

Main characteristic:

  •  Current transformers, isolation, grounding switch combination, compact, lightweight design, which can realize the whole transportation, save area, relative AlS station save covers an area of 70%, suitable for power plant and substation construction, expansion or reconstruction project and railway electrification construction, especially suitable for old substation upgrading, reduce the construction difficulty and investment scale.

  • CT is arranged on two sides of the circuit breaker (different from the structure of mainstream manufacturer’s' similar products, complying with the requirement "blind area of main protection shall be avoided in the configuration of protective current transformer and the allocation of secondary winding" as specified in the Technical specifications of Relay Protection and Safety Automatic Device, improving the reliability of power supply.

  • The product also adopts straight-through CT, completely solving problems such as excess moisture and low insulation margin and promoting the insulation resistance and reliability of the product.

  •  The product is configured with a grounding switch on equipment side and line side in a built-in way, with reliable earthing that prevents safety hazards in maintenance.

  • The circuit breaker adopts light-spring operating mechanism and aluminum frame of integral casting. It’s closing-opening springs adopt spiral dual-pressure spring, with a compact and indefatigable structure, realizing a mechanical life of 10000compressions.

  •  Aviation plugs are used to connect CB, DES & ES mechanism cases and control cabinet, facilitating field installation and commissioning.

  •  The structure of three-position disconnecting/grounding switch is stable and reliable.

  •  The inlet and outlet lines are connected to the equipment through bushings. Composite insulation bushings and porcelain bushings can be selected., Compared with GlS equipment, the enclosed bushings are omitted, and theSF6 gas consumption is less (less than 50% of GiS consumption), which is green and economical.

Main technical parameters:

image.png

Order Notice:

  • Application working condition (incoming/outgoing line, main transformer or PT interval);

  • Rated electrical parameters (voltage, current, breaking current and so on);

  • Conditions of use environment (ambient temperature, altitude and class of environmental pollution);

  • Control voltage of operating mechanism and motor voltage;

  • Quantity. current ratio, grade combination and secondary load of current transformer;

  • Name and quantity of spare products, spare parts & special tools and equipment (to be ordered separately).

What are the structural characteristics of hybrid high-voltage gas-insulated switchgear? 

Hybrid Gas Insulation System:

  • Typically, a mixture of SF₆ and other gases (such as N₂, CF₄, etc.) is used as the insulating medium. This design aims to combine the properties of different gases. For example, SF₆ has excellent insulating and arc-quenching properties but poses environmental concerns due to its greenhouse effect. By mixing it with other gases, the amount of SF₆ can be reduced while maintaining good insulation performance. The insulation system consists of sealed gas compartments that enclose the high-voltage conductive parts, preventing contact with the external environment and ensuring reliable electrical insulation.

Compact Design Layout:

  • To fully utilize the insulating properties of the hybrid gas, the internal structure of the equipment is designed to be compact. Various components of the switchgear, such as circuit breakers, disconnect switches, earthing switches, and busbars, are carefully arranged to minimize the overall size of the equipment. For example, compact circuit breaker designs and optimized busbar layouts enable efficient electrical connections and functional integration within a limited space.

Reliable Sealing Structure:

  • To ensure good insulation performance, the hybrid gas must be maintained at specific pressure and purity levels. Therefore, the equipment features highly reliable sealing structures. High-quality sealing materials (such as rubber O-rings, metal gaskets, etc.) and sealing techniques are used to ensure the airtightness of the gas compartments and prevent gas leakage. Additionally, the sealing structure must withstand temperature changes, mechanical vibrations, and other factors, maintaining stable sealing performance over the long term.


Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Dedicated Vacuum Contactor Solution for Port Shore Power Systems
    I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
    09/13/2025
  • ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
    Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
    09/13/2025
  • Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
    1.Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
    09/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.