40.5kV Manual Operation Mechanism for Spring-Loaded Inlet of SF6 Gas-Insulated Switchgear

  • 40.5kV Manual Operation Mechanism for Spring-Loaded Inlet of SF6 Gas-Insulated Switchgear

Key attributes

Brand Switchgear parts
Model NO. 40.5kV Manual Operation Mechanism for Spring-Loaded Inlet of SF6 Gas-Insulated Switchgear
Rated voltage 40.5kV
Rated normal current 630A
Rated frequency 50/60Hz
Series RNC-40.5

Product descriptions from the supplier

Description

This series of mechanisms adopts flat spiral spring energy storage to control the action of the load switch, and the grounding operation adopts compression spring energy storage control. There are three operating stations for closing, opening, and grounding in the work position. This series of products has five interlocking functions, small size, easy installation, and strong adaptability. This product has passed the full inspection and is in compliance with the relevant requirements of G8 3804-2004 "3.6kV-40.5kV High Voltage AC Load Switches", GB 3906-2006 "3.6-40.5kV AC Metal Enclosed Switchgear and Control Equipment", and GB16926-2009 "High Voltage AC Load Switchgear Fuse Combination Electrical Appliances".Suitable for 33-40.5kV SF6 gas filling cabinet

Operatinginstructions for spring mechanism

Closing operation
Make sure to check the products without transportation will be fixed on thedeformation mechanism of load switch, the use of the operating handle is insertedinto the upper part of special institutions, clockwise rotation about 90 degrees, theload in the body underthe action ofthe spring force main loop switch. Or the electricoperation, press the closing button, the motor drives the mechanism to completethe switch on and turn operation, at this time can not carry on the ground operation.

Switching operation
The operating handle is inserted into the upper part of the mechanism and rotatescounterclockwise about 90 degrees, and the load switch is operated under theaction of the force ofthe mechanism spring, and the main circuit is split. Or electricoperation, according to the switch button, the motor drives the mechanism tocomplete the switching operation, at this time, it can do the closing operation or thegrounding operation.

Earthing closing and earthing switching operation

The operating handle is inserted into the lower part of the mechanism and rotatesabout 90 degrees clockwise. The load switch is closed to the ground circuit underthe action of the force of the mechanism spring, so that the main circuit closingoperation can not be performed at this time.The operating handle rotates about 90 degrees counterclockwise, and the loadswitch switches the grounding circuit under the action of the force of the mechanismspring, which can be used for closing operation or grounding operation.

Modelcomposition and meaning

Appearance and installation dimensions

FAQ
Q: What are the core functions of the 40.5kV gas cabinet incoming manual operating mechanism?
A:
Its core functions are focused on incoming line isolation, high-load bearing, safety protection and interlock coordination, which are the core guarantee for the safe operation of the main incoming line system: ① Main incoming line isolation drive: Through manual operation, output stable and high mechanical force to drive the incoming line isolator to open/close, realizing reliable isolation of the 40.5kV main incoming line circuit; ② High-load bearing: Adopt reinforced structural design, with strong load-bearing capacity and impact resistance, adapting to the high-voltage and high-current working condition of the main incoming line; ③ Safety protection: With over-torque protection, limit positioning and anti-misoperation functions, avoiding mechanism damage caused by excessive manual operation force and ensuring the incoming line isolator is in the correct opening/closing position; ④ Interlock coordination: Cooperate with the main circuit breaker, cabinet door and earthing switch to realize interlock control, preventing misoperations such as live isolation of incoming lines, closing with grounding and opening the cabinet door with electricity; ⑤ Maintenance convenience: Simple structure, few electronic components, low maintenance difficulty and low failure rate.
Q: What is a 40.5kV gas cabinet incoming manual operating mechanism?
A:
It is a dedicated manual mechanical component matched with 40.5kV gas cabinet incoming line isolators, mainly used to drive the incoming line isolator to complete opening and closing actions, realizing safe isolation and switching of the medium-voltage main incoming line circuit. Its core characteristics include 3 points: ① Matching scenario: Specially designed for 40.5kV SF6 gas-filled cabinets, with high load-bearing structure, adapting to the high-voltage main incoming line working condition; ② Operation mode: Adopt manual operation (handle/hand crank), no external power supply required, stable and reliable even in power supply instability scenarios; ③ Core function: Drive the incoming line isolator to move reliably, realize main circuit isolation, and cooperate with the cabinet door, main circuit breaker and earthing switch to complete mechanical interlock. It is widely used in 40.5kV medium-voltage distribution systems such as power grids, industrial and mining enterprises, commercial parks and power stations.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.