• 51.2kWH-215kWH PV and ESS integrate machine
51.2kWH-215kWH PV and ESS integrate machine
$336000.00
Model
KP-100-215K
KP-50-107K
KP-30-60K
KP-20-50K
Basic info
Brand RW Energy
Model NO. PV&ESS integrate machine
Cooling mode Forced air cooling
Rated Output Rating 100kw
Energy storage capacity 215kWh
Rated PV input power 110kW
Series Industrial&Commercial energy storage
Product Detail

光储一体机.png

Peculiarity                                               

  • Modular storage parallel design concept, improve system stability, easy installation and maintenance, easy expansion.

  • Fast realization of grid-connected/off-grid PV collaboration.

  • Adjustable energy scheduling, users can change the charge and discharge logic according to the power consumption strategy of different periods in the area.

  • Multiple protection and safety devices to ensure the safety of use.

  • Energy Balance Management controllers are used to refine energy management of energy storage systems down to the battery PACK level.

  • Battery PACK horizontal energy balance management controller to avoid capacity loss caused by mismatches.

  • Outdoor modular energy storage converter cabinet design, high power density, easy maintenance.

Technical parameter

image.png

image.png

 How does the photovoltaic energy storage machine work?

The photovoltaic and energy storage integrated machine is a solution that integrates a photovoltaic power generation system and an energy storage system. It is suitable for various application scenarios such as households, commerce, and industry. This type of integrated machine usually contains a photovoltaic inverter, energy storage batteries, a battery management system (BMS), an energy management system (EMS), and other necessary components.

Working principle:

  • Energy storage:When the photovoltaic system generates excess electrical energy, the alternating current (AC) is converted into direct current (DC) through the inverter and stored in the battery module.

  • Energy release:When power demand increases or supply is insufficient, the stored direct current is converted into alternating current through the inverter and transmitted to the power grid or directly used by users.

  • Intelligent scheduling:The EMS intelligently schedules the charging and discharging process of the energy storage system according to electricity prices, grid demands, and user settings to maximize economic benefits.



Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High Voltage Electrical Apparatus/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!