75KVA to 2500KVA Three Phase Substation Ground-Mounted Pad Mounted Transformer

  • 75KVA to 2500KVA Three Phase Substation Ground-Mounted Pad Mounted Transformer

Key attributes

Brand ROCKWILL
Model NO. 75KVA to 2500KVA Three Phase Substation Ground-Mounted Pad Mounted Transformer
Rated voltage 10kV
Phases Three-phase
Series ZGS

Product descriptions from the supplier

Description

Product Description

The Rockwill Compact Pad-Mounted Transformer Substation integrates transformer, switchgear and protection systems into a single, space-saving unit for voltages up to 75kV and capacities from 75kVA to 2500kVA. This innovative solution combines robust construction with intelligent design to deliver reliable power distribution in diverse environments.

Key Features

  • Advanced Enclosure System

The substation features a durable multi-layer enclosure with thermal insulation, optimized ventilation, and corrosion-resistant protection. Available in various materials including marine-grade aluminum, galvanized steel, stainless steel, and composite panels, the design ensures IP54-rated protection against dust, water, and vermin while maintaining an aesthetic appearance.

  • High-Voltage Switchgear System

Configurable with XGN15, HXGN17 or KYN28A switchgear options, the system supports multiple power supply modes including loop network, terminal supply, and dual-source redundancy. The integrated solution includes precision metering components and offers choice of SF6 load switches or vacuum circuit breakers, all protected by a comprehensive safety interlock system.

  • Low-Voltage Distribution System

The modular design incorporates GGD, GCS or MNS panel options with complete functionality for power distribution, lighting control, reactive power compensation and energy metering. Intelligent breakers with microprocessor protection and remote control capability are available alongside standard switching solutions in an ergonomic, maintenance-friendly layout.

  • Technical Advantages

With 30% more compact footprint than conventional solutions, the substation delivers superior performance through optimized heat dissipation and faster installation of pre-tested modular assemblies. All units undergo rigorous type-testing according to IEC 62271 standards.

  • Applications & Support

Ideal for urban networks, industrial parks, renewable connections and critical facilities, every Rockwill substation comes with factory test reports, 5-year warranty, lifetime support and custom configuration services. Our engineering team stands ready to develop solutions tailored to your specific voltage requirements, environmental conditions and smart grid integration needs.

Technical Parameters

Working Conditions

  • Altitude: no more than 2000M.

  • Ambient temperature: high temperature: +40ºC; Low temperature: -45ºC : high monthly average temperature: +30ºC : high annual average temperature: +20ºC;

  • installation environment: no explosive, corrosive liquid, gas and dust, installation site without violent shock, allowed in a certain period of time Or run completely submerged in water.

  • Ground acceleration induced by earthquake Ag; The horizontal direction is lower than 3m/s; The vertical direction is lower than 1.5m/s.

  • the waveform of the power supply voltage: approximately sine wave.

  • three-phase power supply symmetry: for three-phase underground transformer, three-phase power supply voltage should be roughly symmetrical.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.