Model
WZ08-160kW-2EJ-20INGYNN
WZ08-160kW-2EU-20INGYNN
WZ08-160kW-2CE-20INGYNN
WZ08-160kW-2E-20INGYNN
WZ08-160kW-2C-20INGYNN
Basic info
Brand RW Energy
Model NO. 160kW 180kW 200kW 240kW 320KW GBT CCS1 CHAdeMO CCS2 Connector Double Gun Fast DC EV Charging Station
Rated Output Rating 160kW
Output Voltage DC 200-1000V
Power Conversion Efficiency ≥95%
Connector Options CCS2+CHAdeMO
Cable Length 5m
Input Voltage 380V
Series DC EV Chargers
Product Detail

Description:

This series of DC fast chargers offers 160kW, 180kW, 200kW, 240kW, and 320kW power options with GBT, CCS1, CHAdeMO, CCS2 connectors, supporting dual-gun simultaneous charging to meet the high-efficiency energy replenishment needs of global EVs. Compatible with domestic GB/T vehicles, European/American CCS models, and Japanese CHAdeMO standards, it enables plug-and-charge convenience for all major EV brands.

Key Features:

  • Full Power Range Coverage: Five power configurations from 160kW to 320kW, suitable for light buses, passenger cars, and electric trucks. The 320kW model charges vehicles from 10% to 80% in just 30 minutes.

  • Dual-Gun Parallel Charging: Two independent charging guns support simultaneous operation, with each gun delivering up to 320kW, significantly enhancing station throughput and reducing user wait times.

  • Universal Compatibility: Integrates four major charging standards (GBT/CCS1/CHAdeMO/CCS2), compatible with over 99% of global EVs, including Tesla, BYD, Volkswagen, Nissan, etc.

  • Intelligent Power Management: Dynamic power allocation system optimizes current distribution between guns, ensuring stable output even during simultaneous charging.

  • Efficient Cooling & Safety: Liquid-cooled thermal management with smart temperature control enables operation in -30°C to 55°C environments. Equipped with overvoltage/overcurrent protection, leakage monitoring, and fireproof design.

  • Flexible Deployment: Wall-mounted or floor-standing installation options, adaptable to highway rest areas, commercial parking lots, and logistics parks. Seamless integration with third-party management platforms.

Specifications:

Project  Technical Parameter
 Power

160kW/180kW/200kW

/240kW/320kW

 Model WZ08/09/10/11/12
Connector  GBT/CCS2/CHAdeMO/CCS1
Max Power 240kW
 Emergency Stop Button Yes
Communication Protocol OCPP1.6 
Input Voltage 380V(-25%,+25%)AC
Frequency、Output Voltage 50Hz、50V~1000VDC
Protection Grade IP54
Power distribution Average power distribution
Power factor >0.99
Peak efficiency 95.5%
 Overall efficiency 94%
auxiliary powersupply 12V
humidness <95%
Soft startup time 3 - 8S
Output voltage error <±0.5%
Output current error >30A ,<±1%;<30A ,<±0.3A
Voltage accuracy <0.5%
Steady flow accuracy <1%
 Voltage ripple <1%
 Current sharing <5%
 Load adjustment rate <1%
 Emc GB/T19826 - 2014:5.4
Starting mode Swipe card/small program scan code
Insulation resistance >10MΩ
 Withstand voltage AC2500V
 Display screen 7"touch screen
 Installation mode Floor
Operating temperature -35°C~+55°C
Charging gun length 5m/7m/8m
 Altitude <2000m 
Outer dimension WZ08:700mm600mm1900mm 
Harmonic distortion <5%

How to fast charge a car at a fast DC EV charging station with dual charging guns?

When two electric vehicles are connected to two charging guns of a charging pile, the charging pile establishes a communication connection with the Battery Management System (BMS) of each vehicle through the communication lines inside the charging guns. It confirms the vehicle's identity information, battery status (such as State of Charge, SOC, battery temperature, etc.), and charging requirements. The charging pile needs to dynamically allocate the total output power according to the actual charging needs of both vehicles. This is typically achieved through an internal power management system that decides how to distribute power based on each vehicle's charging request and the current state of the power grid. For example, if one vehicle has a lower battery capacity and the other has a higher battery capacity, the charging pile may prioritize providing a greater charging power to the vehicle with the lower battery capacity. Power conversion then takes place.

Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High Voltage Electrical Apparatus/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.