• Complete Set of Large Capacity 160kA Generator Circuit Breaker
Complete Set of Large Capacity 160kA Generator Circuit Breaker
discuss personally
Model
ZHN10-24 /27000-160
Basic info
Brand ROCKWILL
Model NO. Complete Set of Large Capacity 160kA Generator Circuit Breaker
Rated voltage 24kV
Rated normal current 27000A
Series Circuit Breaker
Product Detail

Description:

This product is suitable for water, thermal power, and nuclear power units with a single generator capacity of 600-800 megawatts. The rated short-circuit breaking current is 160 kiloamperes, and the rated peak withstand current is 440 kiloamperes. In 2013, it was appraised by the China Machinery Industry Federation and successfully applied in the Xiangjiaba project, achieving complete localization, making China one of the few countries in the world capable of producing large capacity generator circuit breakers, and reducing engineering procurement costs for domestic users.

Product Performance:

  • Implemented according to the latest IEC standards.

  • High insulation level: meeting the insulation requirements of the products under the environment of 3,000m above sea level.

  • High long-term flow capacity: adopts natural cooling, no auxiliary heat dissipation device, the rated flow capacity up to 25,000A. With forced air cooling by fan, the rated flow capacity up to 27,000A.

  • Excellent 0breaking performance: the effective value of Ac component of short-circuit breaking current has is 160kA and the DC component is as high as 87%, which meets the current breaking requirements under various fault conditions.

  • High mechanical reliability: Innovative design of circuit breaker drive ensures that the product can meet the breaking performance under the small input operation power, and realize the mechanical life requirement of operation for 5,000times, Disconnector and earthing switch meet the mechanical life requirement of operation for 10,000 times.

  • Comprehensive safety protection measures: Pressure release device is installed at the top of the circuit breaker. When the gas pressure in the arc extinguishing chamber exceeds 1.2MPa due to an accident, the gas will be released to ensure the safety of the personnel and surrounding equipment. The product design can ensure the stable operation of the power plant.

Product Structure:

  • The product consists of three single poles, and each pole has an individual enclosed metal enclosure mounted on the same chassis.

  • Circuit breaker is equipped with hydraulic spring operating mechanism; The disconnector and earthing switch are equipped with motor operating mechanism; The driving modes are all three-phase mechanical linkage.

  • Each operating mechanism is installed on the side of the product close to the control cabinet.

  • SF6 is used as internal insulation and arc-extinguishing medium for circuit breaker, and adopts self-energy arc extinguishing principle. It is mainly composed of the main contact system, arc extinguishing system and driving system.

  • Air is used as insulation medium to isolate the break of the disconnector, the isolation moving contact adopts telescopic direct-acting structure, and the fixed contact adopts inner and outer two-layer contact finger structures, when closing, both the inner and outer surfaces of the moving contact are in contact with the contact finger, thus ensuring sufficient current capacity. Double guiding devices are used to ensure smooth closing of the moving contact.

  • Air is used as insulation medium to isolate the break of the earthing switch. The fixed contact is installed on the support of the main circuit, and the moving contact is installed on the bottom plate of the single pole enclosure.
    微信图片_20240615104546_修复后.png

Typical applications:
微信图片_20240615104629_修复后.png
微信图片_20240615104649_修复后.png

160kA intelligent generator circuit breaker:
微信图片_20240615104608_修复后.png

160 kA intelligent generator circuit breaker not only has basic protection function, but also integrates potential transformer, current transformer, lightning arrester and other components. Each product is equipped with a set of intelligent on-line monitoring device to realize on-line monitoring of conductor temperature, mechanical characteristics of circuit breaker, SF6 gas condition and so on.
Main technical parameters:

image.png

What are the technical parameters of generator circuit breaker?

Rated Voltage:

  • This is the highest voltage at which the generator circuit breaker can operate normally. For example, for generator circuit breakers in large thermal power plants, the rated voltage may reach 20 - 30 kV or even higher. This parameter must match the rated output voltage of the generator to ensure safe and reliable operation under both normal and fault conditions.

Rated Current:

  • It indicates the maximum current that the generator circuit breaker can carry continuously. The selection of the rated current should be based on the rated capacity of the generator. For instance, a 100 MW generator may have a rated current in the range of several thousand amperes, and the rated current of the generator circuit breaker needs to meet this requirement to ensure it can handle the generator's output current during normal operation.

Short-Circuit Breaking Capacity:

  • This is a critical parameter that measures the ability of the generator circuit breaker to interrupt short-circuit faults. When a short circuit occurs at the generator outlet or on the grid side, the circuit breaker must be able to quickly interrupt the high short-circuit current to prevent the fault from spreading. For example, in large power plants, the short-circuit breaking capacity of the generator circuit breaker may reach tens of kiloamperes or even higher, requiring the breaker to have strong arc-quenching capabilities and good thermal and dynamic stability.

Making Current:

  • The making current refers to the maximum instantaneous current that the circuit breaker can withstand when it is closed. During generator startup or when the grid recovers after a fault, there may be significant inrush currents. The circuit breaker must be able to safely close these currents; otherwise, it could result in issues such as contact welding.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!