• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


DNH50-50 DC Isolate Switch PV System Disconnection Concentrated Inverter Protection

  • DNH50-50 DC Isolate Switch PV System Disconnection Concentrated Inverter Protection
  • DNH50-50 DC Isolate Switch PV System Disconnection Concentrated Inverter Protection
  • DNH50-50 DC Isolate Switch PV System Disconnection Concentrated Inverter Protection

Key attributes

Brand Switchgear parts
Model NO. DNH50-50 DC Isolate Switch PV System Disconnection Concentrated Inverter Protection
Rated normal current 50A
number of poles 2P
Series DNH50

Product descriptions from the supplier

Description

The  DNH50-50 Series DC Isolate Switch is specifically engineered for DC circuit disconnection in PV and energy storage systems. Unlike conventional DC isolator switches, it features a patented arc-free mechanism, eliminating arc flash hazards during manual operation. This not only improves safety but also extends the lifespan of internal components.

Whether you’re integrating it into solar inverters, battery packs, or string combiner boxes, the DNH50-50 DC Isolate Switch provides dependable isolation for routine maintenance, emergency power-off, or fault handling.

DC Isolate Switch Key Features

Arc-Free Operation: Zero arc during switching, ensuring safety for operators and system components.

Wide Voltage Range: Available in 600V, 700V, 800V, 1200V, and 1500V DC versions.

Robust Design: Flame-retardant nylon casing (UL94 V-0 rated) offers superior thermal and environmental resistance.

Flexible Mounting: Supports both rail and screw installation, fitting seamlessly into various DC cabinet layouts.

Compact Form Factor: Ideal for space-limited PV inverters, combiner boxes, and battery energy storage cabinets.The suitable cabinets are mostly specialized cabinets for photovoltaic and energy storage fields. The specific models and adaptation details are as follows: QHWI-PVS series AC combiner box (such as QHWI-PVS4-AC, QHWI-PVS6-AC), GGD400KB photovoltaic grid connected cabinet, GSL-HV51200 high-voltage energy storage cabinet, HV48100 SE outdoor energy storage cabinet

Main Technical Parameters
DNH50-50
Frame Current (A) 50
Rated Thermal Current lth (A) 50
Insulation Voltage Ui (v) 1500
Rated impulse Withstand Voltage Uimp (kV) 8
DNH50-50
Rated Current (A)
Rated Voltage DC (v) 600 700  800 1000 1200 1500
DC-21B, DC-PV1 2 Layers in Series 50 50  50 40 35 32
DC-PV2 2 Layers in Series 18 18  18 15 13 12
DNH50-50H
Frame Current (A) 50
Rated Thermal Current lth (A) 50
Insulation Voltage Ui (v) 1500
Rated impulse Withstand Voltage Uimp (kV) 8
DNH50-50
Rated Current (A)
Rated Voltage DC (v) 800 1000 1200   1500
DC-21B, DC-PV1 4 Layers in Series 50
DC-PV2 4 Layers in Series 45 40 32   25
 
Rated short-time withstand current law (kA*1s) 0.7
Rated short-circuit-making capacity lcm (kA) 1.5
Mechanical life (cycles) 9700
Electrical life (cycles) 300
Product certification CCC、CE
Operating torque (N*m) 1.5 ~ 2.2
Mounting method Cabinet Door Installation
Protection rating Whole Machine lP20

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.