• 35kV 66kV 110kV Shunt Reactor
35kV 66kV 110kV Shunt Reactor
discuss personally
Model
BKDGKL-35/5000
Basic info
Brand POWERTECH
Model NO. Shunt Reactor
Rated voltage 35kV
Rated normal current 5000A
Series BKDGKL
Product Detail

Description:

The shunt reactor is connected between the phase and the ground, between the phase and the neutral point , between phases in the power system to play the role of reactive power compensation. It is used to compensate the capacitive charging power of ultra-high voltage lines, which is helpful to limit the increase of power frequency voltage and operating over-voltage in the system, reduce the insulation level of ultrahigh voltage system, improve the voltage distribution along the line and increase the stability and power transmission capacity of the system.

Electrical schematic:

企业微信截图_17224056085811.png


Reactor Code and Designation:

企业微信截图_17224056319916.png


Parameters:

image.png

What is the reactive power compensation principle of shunt reactor?

Reactive Power Compensation Principle:

  • In power systems, most loads are inductive (such as motors, transformers, etc.). Inductive loads consume reactive power during operation, which can lead to a decrease in the power factor of the grid.

  • When a shunt reactor is connected to the grid, its primary function is to provide inductive reactive power to the grid. According to the principle of electromagnetic induction, when an alternating current flows through the windings of the reactor, it generates an alternating magnetic field in the core. This magnetic field interacts with the electric field in the grid, facilitating the exchange of reactive power.

  • When the grid lacks reactive power, the shunt reactor absorbs capacitive reactive power (equivalent to generating inductive reactive power), thereby increasing the power factor of the grid. This reduces the transmission of reactive currents in the grid, lowers line losses, and improves the efficiency and quality of power transmission.

Example:

  • In the distribution network of an industrial enterprise, if a large number of asynchronous motors are operating simultaneously, the power factor of the grid can drop to a low level. Installing a shunt reactor in this scenario can compensate for the reactive power, raising the power factor to a reasonable range. This not only reduces the company's electricity costs but also alleviates the burden on the grid.



Know your supplier
POWERTECH
We are an electrical company that manufactures and sells high and low voltage electrical products.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$120000000
Professional Experience
7 years
Workplace
580000m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×