DS4A 12kV 24kV 40.5kV 72.5kV 126kV 145kV 170kV High voltage disconnect switch factory

  • DS4A 12kV 24kV 40.5kV 72.5kV 126kV 145kV 170kV High voltage disconnect switch factory

Key attributes

Brand ROCKWILL
Model NO. DS4A 12kV 24kV 40.5kV 72.5kV 126kV 145kV 170kV High voltage disconnect switch factory
Rated voltage 40.5kV
Rated normal current 1250A
Rated frequency 50/60Hz
Rated peak value withstand current 80kA
Rated short-time withstand current 31.5kA
Series DS4A

Product descriptions from the supplier

Description

Product introduction:

The DS4A-12/126/145/170D (W) High-Voltage Disconnector is an outdoor high-voltage power transmission equipment designed for three-phase AC systems with a frequency of 50Hz/60Hz. It is used to interrupt or connect high-voltage lines under no-load conditions, enabling the switching and connection of power lines as well as the modification of power operation modes. Meanwhile, it can provide safe electrical isolation for high-voltage electrical equipment such as busbars and circuit breakers.

This product adopts a double-insulator horizontal center-break structure, which is openable in the middle and supports the installation of earthing switches on one or both sides. The high-voltage disconnector is equipped with CS14G, CS11 type manual operating mechanisms or CJ2 type motorized operating mechanisms to achieve three-pole interlocking; the earthing switch completes three-pole interlocking through the CS14G type manual operating mechanism. The product design fully considers the working principles and precautions for disconnectors, effectively avoiding common operational risks.

In August 2005, this product passed the improvement technology review by State Grid Corporation (Jiangsu provincial branch).

The DS4A series high-voltage disconnector consists of three single poles and an operating mechanism. Each single pole includes a base, post insulators, and conductive parts. Rotatable post insulators are installed on both sides of the elongated base, and the contact arms of the conductive switch blade are respectively fixed at the tops of the insulators. When the operating mechanism drives one end of the insulator to rotate, it drives the other end of the insulator to rotate reversely by 90° through a cross connecting rod, making the conductive switch blade rotate on the horizontal plane to realize the opening and closing operations of the disconnector. A horizontal insulating break is formed when opening. During the design phase, the product focuses on optimizing the reliability of the mechanical structure, which can reduce the probability of isolator mechanical failures. Meanwhile, it adopts an anti-overheating design for conductive parts to minimize the occurrence of overheating issues in busbar isolating switches.

Main characteristic:

  • The conductive arm made of rectangular Al-alloy pipes is characterized by high strength, light weight, large radiation area and corruption-resistance.

  • Adopt particular copper alloy to develop the self-contained contact, The contact point is tightened by the elastic force of the contact itself. The contact spring is eliminated to avoid possible drop of the contact in gripping force due to the spring's corrosion and shunting, heating and annealing, possible increment in contact resistance, and possible vicious cycle of the growing heat of the contact. The contact is made of curved copper plate, forming a large connection area with he conductive arm. In the opening and closing processes, there isa short trip of friction between the contact and the finger and he required operating force is small. The conductive part has been acknowledged by the Chinese competent authority as a new and practical patent.(Patent No.. Z103 2 20022.6)

  • The rotating parts of the disconnect switch are designed to be free of any maintenance. The rotating base is designed into a seal structure which denies the access of moisture, dust and harmful gases so that No.2 low-temperature lubricating cream within the bearing will not run off or harden, Within the bearing base are thrust ball bearing and radial ball bearing, both of which will share the gravity and horizontal component of the Switch Disconnector so that the operating torque will not increase after the long-term operation of the disconnect switch.

  • Provide one key sequential control "double confirmation" function expansion.

Main technical parameters:

Among these voltage levels 225kV/230kV/330kV/345kV Disconnect Switch, the rated short-circuit breaking current is 63kA, and customization is available.

NO

Specifications

Unit

Value

1

Rated voltage

kV

12

24

40.5

72.5

126

145

170

2

 

1min power frequency withstand voltage (r.m.s)}

Phase to phase to earth

kV

55

65

95

160

230

275

325

Across isolating distance

kV

48

79

118

200

230(+70)

275(+85)

375

3

Lightning impulse withstand voltage (peak 1.2/50μs)}

Phase to phase to earth

kV

96

125

185

350

550

650

750

Across isolating distance

kV

85

215

215

410

550(+100)

650(+120)

860

4

Rated frequency

Hz

50/60

5

Rated current

A

630/1250/2000

1250/2000/2500/3150/4000

1250/1600/2000/2500/3150/4000

1600/2000/2500/3150/4000

1600/2000/2500/3150/4000

2000

6

Rated short-time withstand current (r.m.s)

kA

31.5

31.5/40/50

40/50

40/50

40/50

40

7

Rated peak withstand current

kA

80

80/100/125

100/125

100/125

100/125

104

8

Rated short-circuit withstand time

S

4

4

4

4

3

3

3

9

Wiring terminal static mechanical load}

Longitudinal

N

500

750

750

750

1250

1250

1250

Horizontal


250

500

500

500

750

750

750

Vertical


300

750

750

1000

1000

1000

10

Creepage distance

mm

300, 372

600, 744

1013, 1256

1813, 2248

3150, 3906

3625, 4495

4250, 5270

11

Mechanical life

times

100000

12

Motor operating mechanism

modes

CJ12

13

Motor voltage

V

AC380/DC220/DC110

14

Control circuit's voltage

V

AC380/AC220/DC220/DC110

15

Opening/closing time

S

7±1

16

Manual operating mechanism

modeL

CS14G

17

Electromagnetic lock' voltage'


AC220/DC220/DC110

Order notice :

Product model, rated voltage, rated current, rated short-time withstand current and creepage distance must be specified at the goods ordering time;

The disconnect switch offers several options of grounding (no, left. right. both left and right). Unless otherwise specified, the goods supplied will be considered as proving the option of right grounding;

Notes:

  • The methods of Judging left and right grounding: hold out both arms and keep the arms In the same direction as the Switch Disconnector is open的The earthing switch will be considered as left grounding if on the left hand side, and right grounding if on the right hand side;

  • The actuator's model and name, voltage and the number of contacts for auxiliary switch;

  • Specify the type of power and voltage degree for the electromagnetic lock of the actuator.

 

 

Documentation Resource Library
Restricted
12 to 550kV Center Side Break Disconnect Switch Installation and Instruction Manuals
Installation Manual
English
Consulting
Consulting
FAQ
Q: What type of disconnector should be selected for projects in coastal areas with frequent sandstorms?
A:

For the specific requirements of coastal areas with frequent sandstorms, it is recommended to select products equipped with dustproof and sand-resistant features:

  • Rockwill Electric: DS7B-420D/3150, an outdoor high-voltage disconnector with an earthing switch, featuring a rated current of 3150A, high insulation withstand capability, strong corrosion resistance, and ease of maintenance, ensuring the safe and stable operation of high-voltage systems.

  • Pinggao Electric: GW27-550(W)/4000, marked with pollution resistance (W), suitable for harsh climatic conditions.

  • Shandong Taikai: GW5-252DD/3150-50, designed with a double-earthing configuration and optional accessories such as sand shields.

  • Changgao Electric: GW5C-252DD/3150, a customized improved version that allows for additional protective measures based on requirements.

Comparison Points:

  • Dustproof and Sand-Resistant Design: Pinggao's products explicitly indicate pollution resistance, while other manufacturers can achieve similar effects by configuring additional accessories.

  • Double-Earthing Configuration: Some models from Rockwill, Taikai, and Changgao support double-earthing, enhancing operational flexibility and safety.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.