Electrical Disconnector DNH8(HGL) Series Side Operation – Load Disconnector

  • Electrical Disconnector DNH8(HGL) Series Side Operation – Load Disconnector
  • Electrical Disconnector DNH8(HGL) Series Side Operation – Load Disconnector

Key attributes

Brand Switchgear parts
Model NO. Electrical Disconnector DNH8(HGL) Series Side Operation – Load Disconnector
Rated normal current 125-630A
number of poles 4p
Series DNH8(HGL)

Product descriptions from the supplier

Description

The elastic-accumulating accelerating mechanism for instant release realizes the rapid making and breaking (13.8m/s), having no relation ship with the speed of the operating handle, and increasing greatly the capability of extinguishing electric arc.

The shell made of unsaturated polyester resin reinforced by glass fibre possesses excellent perform ance of flame resistant, dielectric performance, safe operation, resist carbonic performance and resist impact performance.

Parallel double gap contact possesses self cleaning functions.Allthe contact materials are copper alloy plated with silver, and possess two separation contact surfaces.Largeclearance

of insulation.Be on "O" , the products can lock the handle with three locks at the same time and thus can avoid error operation.

Low voltage distribution cabinets that require side layout operation space are commonly used in power distribution systems in industries such as construction and electricity. The specific cabinet body and model details are as follows: GGD fixed low-voltage switchgear, GCK withdrawable low-voltage switchgear, GCS withdrawable low-voltage switchgear, XL-21 power cabinet, etc

Product Details

Electrical Disconnector-2

DNH8(HGL)-125~630/C Side Operation Outline and Installation Dimension

Electrical Disconnector-3

Specifications

Overall dimension

Installation dimension

In

A

B C D E J1 J2 N P R S U φX Y J K

L

125A/3

273

135 147 156 83 29 195 28 36 20 25 115 9 55 120 95

7

125A/4

303

135 147 156 83 29 225 22 36 20 25 115 9 55 150 95 7
160A/3

273

135 147 156 83 29 195 28 36 20 25 115 9 55 120 95

7

160A/4

303

135 147 156 83 29 225 22 36 20 25 115 9 55 150 95

7

200A/3

345

170 167 166 95 30 235 33 50 25 30 140 11 64 160 116

9

200A/4

395

170 167 166 95 30 285 33 50 25 30 140 11 64 210 116

9

250A/3

345

170 167 166 95 30 235 33 50 25 30 140 11 64 160 116

9

250A/4

395

170 167 166 95 30 285 33 50 25 30 140 11 64 210 116

9

315A/3

436

240 213 197 129 45 298 42 50 32 40 206 11 84 270 179

9.5

315A/4

496

240 213 197 129 45 358 38 50 32 40 206 11 84 210 179

9.5

400A/3

436

240 213 197 129 45 298 42 65 32 40 206 11 84 270 179

9.5

400A/4

496

240 213 197 129 45 358 38 65 32 40 206 11 84 210 179

9.5

500A/3

436

260 213 197 129 45 298 42 60 40 50 220 13 84 210 179

9.5

500A/4

496

260 213 197 129 45 358 38 60 40 50 220 13 84 270 179

9.5

630A/3

436

260 213 197 129 45 298 42 60 40 50 220 13 84 210 179

9.5

630A/4

496

260 213 197 129 45 358 38 60 40 50 220 13 84 270 179

9.5

Electrical Disconnector DNH8(HGL)-1000~1600A/C Side Operation Outline and Installation Dimension

isolator switch on or off

Electrical Disconnector-4

Specifications

Overall dimension

Installation dimension

In

A

B C D J1 N P R S V W X Y J

K

1000A/3

582

308 242 150 450 53.5 120 60 55 35 20 16.5 109 353 220
1000A/4

697

310 242 150 565 50.5 120 60 55 35 20 16.5 110 471

220

1250A/3

582

336 242 150 450 53.5 120 80 68 40 35 16 109 353

220

1250A/4

697

338 242 150 565 50.5 120 80 68 40 35 16 110 471

220

1600A/3

582

336 242 150 450 53.5 120 80 68 40 35 16 110 353

220

1600A/4

697

338 242 150 565 50.5 120 80 68 40 35 16 111 471

220

 

Electrical Disconnector DNH8(HGL)-2000~3150A/C Side operation outline and installation dimension

Electrical Disconnector-5Electrical Disconnector-6

Specifications

Overall dimension

Installation dimension

In

A

B C D J1 N P R S V W X Y Y1 J

K

2000A/3

582

445 330 239 450 53.5 120 80 90 40 40 20 102 207.5 353

220

2000A/4

697

447 330 239 565 50.5 120 80 90 40 40 20 103 208.5 471 220
2500A/3

582

445 330 239 450 53.5 120 80 90 40 40 20 102 207.5 353

220

2500A/4

697

447 330 239 565 50.5 120 80 90 40 40 20 103 208.5 471

220

3150A/3

582

492 330 239 450 53.5 120 120 101 50 50 21 75.5 235.5 353

220

3150A/4

697

494 330 239 565 50.5 120 120 101 50 50 21 76.5 236.5 471

220

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.