Isolating Switch DNH8(HGL)/H Series Operation Behind the Cabinet – Load Disconnector

  • Isolating Switch DNH8(HGL)/H Series Operation Behind the Cabinet – Load Disconnector

Key attributes

Brand Switchgear parts
Model NO. Isolating Switch DNH8(HGL)/H Series Operation Behind the Cabinet – Load Disconnector
Rated normal current 1000A
number of poles 4p
Series DNH8(HGL)/H

Product descriptions from the supplier

Description

Isolating Switches with a current capacity of 160 to 1600 Amperes are suitable for use in circuits for making and breaking connections, as well as for electrical isolation. Switches with a rated current of 1000 Amperes or more are only to be used for electrical isolation. Three-pole and four-pole (3+1) switches are available. Suitable for low-voltage distribution cabinets, the following are specific cabinet bodies and details: GGD type low-voltage fixed switchgear, MNS type low-voltage withdrawable switchgear, GCS type low-voltage withdrawable switchgear, GCK type low-voltage withdrawable switchgear

Switches rated 1600 Amperes or less are available with an observation window, through which the state of the contacts (open or closed) can be directly observed.

Auxiliary contacts can be fitted if required.

Note: This Isolating Switch product only provides operation outside the cabinet

Order model: DNH8 (HGL) -630/3JH

If a visual observation window is required, the Isolating Switch order model is DNH8 (HGL) -630/3JKH

Outline and Installation Dimension (mm)

Isolating Switch -2

Specifications

Overall dimension

Installation dimension

In

A

B C D D1 N P R U φX F H J K

L1

125A/3

140

135 17 15 93 75 36 20 115 9 50 10 120 95

7

125A/4

170

135 17 15 93 75 36 20 115 9 50 10 150 95

7

160A/3 140 135 17 15 93 75 36 20 115 9 50 10 120 95 7
160A/4

170

135 17 15 93 75 36 20 115 9 50 10 150 95

7

200A/3

180

170 18 20 104 105 50 25 140 11 79 15 160 115

9

200A/4

230

170 18 20 104 105 50 25 140 11 79 15 210 115

9

250A/3

180

170 18 20 104 105 50 25 140 11 79 15 160 115

9

250A/4

230

170 18 20 104 105 50 25 140 11 79 15 210 115

9

315A/3

230

240 20 30 137 135 65 32 206 11 95 20 210 135

11

315A/4

290

240 20 30 137 135 65 32 206 11 95 20 270 135

11

400A/3

230

240 20 30 137 135 65 32 206 11 95 20 210 135

11

400A/4

290

240 20 30 137 135 65 32 206 11 95 20 270 135

11

500A/3

230

260 20 30 137 135 65 40 220 13 95 20 210 135

11

500A/4

290

260 20 30 137 135 65 40 220 13 95 20 270 135

11

630A/3

230

260 20 30 137 135 65 40 220 13 95 20 210 135

11

630A/4

290

260 20 30 137 135 65 40 220 13 95 20 270 135

11

Isolating Switch -3

Specifications

Overall dimension

Installation dimension

In

A

B N P R V W X Y J

K

1000A/3

378

308 174 120 60 35 20 16.5 49 350

220

1000A/4

493

310 235 120 60 35 20 16.5 48 471

220

1250A/3

378

336 174 120 80 40 35 16 49 350

220

1250A/4

493

338 235 120 80 40 35 16 48 471

220

1600A/3

378

336 174 120 80 40 35 16 50 350

220

1600A/4

493

338 235 120 80 40 35 16 49 471

220

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.