• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


JDZW2-36 Outdoor Voltage Transformer

  • JDZW2-36 Outdoor Voltage Transformer

Key attributes

Brand Wone Store
Model NO. JDZW2-36 Outdoor Voltage Transformer
Rated frequency 50/60Hz
Primary voltage 33kV
Secondary voltage 110V
Series JDZW

Product descriptions from the supplier

Description

Product Overview

JDZW2-36 voltage transformer, outdoor epoxy resin casting and double pole insulated VT, is widely used for measuring current, electric energy and protective relaying in the isolated neutral system with the frequency 50Hz or 60Hz and insulation voltage 36 kV (Up to 40.5kV).

The iron core adopts advanced cold-rolled silicon steel sheet. High voltage outgoing line of primary winding was fetched out from top of the product; outgoing line of secondary winding was fetched out from transverse side of the product.

Key Features

  • Fully Enclosed Insulation Structure:The product features a fully enclosed post-type structure with an outer silicone rubber insulation layer, effectively resisting pollution and moisture. This design not only enhances moisture resistance but also significantly improves anti-fouling flashover performance, making it ideal for high-pollution outdoor environments and ensuring long-term reliable operation under harsh conditions.

  • High-Precision Voltage Transformation:This voltage transformer accurately measures voltage, converting 36kV high voltage into low voltage suitable for measurement and protection devices. With voltage ratio error controlled within a minimal range, it meets high-precision metering and protection requirements, providing reliable voltage data for power system stability and ensuring timely and accurate operation of relay protection devices.

  •  Compact, Lightweight & Easy Installation:Thanks to the fully enclosed epoxy resin casting process, the transformer is compact, lightweight, and can be installed in any position and orientation. It offers a convenient installation solution for space-constrained locations such as substations and outdoor distribution boxes, saving installation space and costs.

  • Excellent Electrical Performance:Equipped with a built-in fuse, the transformer quickly cuts off the circuit during faults to protect the voltage transformer (PT), with easy fuse replacement. The secondary outlet terminals are sealed with metal protective covers to prevent foreign objects from entering, further enhancing electrical insulation performance and safety while reducing the risk of faults caused by electrical connection issues.

Main technical parameter

  • Rated primary voltage:30 kV or 33 kV or 35 kV  etc.

  • Rated secondary voltage:100 V or 110 V

  • Rated power-frequency withstand voltage: 70kV

  • Rated lightning impulse withstand voltage: 170kV

  • Technical standard accords with IEC 60044-2.2003.

Other parameters pls see as follow:

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

Outline drawing

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Application of Smart Grid Technologies in Line Loss Management of Low-Voltage Transformer Zones
    As an essential component of the distribution network, low-voltage distribution areas (hereinafter referred to as "low-voltage transformer zones") directly affect the economic benefits of power supply enterprises and the quality of electricity consumption for end-users through their line loss issues. However, traditional management approaches have obvious shortcomings in terms of accuracy and efficiency. In this context, the application of smart grid technologies provides new solutions for line
    11/29/2025
  • Uncertainty Evaluation for Grid Electronic Voltage Transformer Measurement
    1. IntroductionGrid electronic voltage transformers, as indispensable measuring components in power systems, have their measurement accuracy directly tied to the stable operation and efficient management of power systems. However, in practice, due to the inherent characteristics of electronic components, environmental factors, and limitations of measurement methods, the measurement results of voltage transformers often involve uncertainty. This uncertainty not only impacts the accuracy of power
    07/24/2025
  • EMC Performance Tests Design and Improvement for Electronic Voltage Transformers
    1 Overview of EMC Performance of Electronic Voltage Transformers1.1 Definition & Requirements of EMCElectromagnetic Compatibility (EMC) denotes a device/system’s ability to operate undisturbed in a given electromagnetic environment and avoid causing unacceptable electromagnetic interference to other entities. For electronic voltage transformers, EMC demands stable measurement performance in complex settings, without interfering with other devices. Their EMC performance must be fact
    07/23/2025
  • Medium voltage transformer inrush current mitigation by control switching device
    Controlled Switching Devices in the Medium Voltage RangeOver three decades ago, Controlled Switching Devices (CSDs) were first introduced to mitigate switching transients caused by high voltage circuit breakers connected to shunt reactors and capacitor banks. Subsequent research expanded their application to transmission lines and power transformers. Initially, these devices optimized switching moments on a per-phase basis using independently pole-operated circuit breakers (IPO).Recently, the su
    02/18/2025
  • What is a Voltage Transformer ?
    What is a Voltage Transformer ?Voltage Transformer DefinitionA voltage transformer, also known as a potential transformer, steps down high system voltages to safer, lower levels suitable for standard meters and relays.Basic OperationThese transformers connect their primary windings across a phase and the ground, operating like other step-down transformers but specifically for voltage management.Standard Secondary VoltageThe secondary voltage output of a typical voltage transformer is generally 1
    08/08/2024
  • What is are High Voltage Transformer?
    What is are High Voltage Transformer?High Voltage Transformer DefinitionA high voltage transformer is defined as a device that changes high-voltage AC power to low-voltage AC power or vice versa, functioning above 35 kV.Core ApplicationsHigh voltage transformers are crucial for testing electrical components, efficient power distribution, and enhancing voltage stability through FACTS systems.Essential FeaturesThese transformers are characterized by their ability to handle high voltages and curren
    08/07/2024
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.