• JDZX16-12R voltage transformer
JDZX16-12R voltage transformer
discuss personally
Model
JDZX16-12R
Basic info
Brand Wone Store
Model NO. JDZX16-12R voltage transformer
Rated frequency 50/60Hz
Primary voltage 22/√3kV
Secondary voltage 110/√3V
Series JDZX
Product Detail

Product Overview

JDZX16-12R voltage transformer, epoxy resin casting and full enclosed construction, is used indoor switch cabinet to measure the current, electric energy and protective relaying in single phase or three phase AC circuit with the frequency 50Hz or 60Hz and highest voltage for equipment 17.5/24 kV.

The iron core adopts advanced cold-rolled silicon steel sheet. High voltage outgoing line of primary winding was fetched out from top of the product; outgoing line of secondary winding was fetched out from transverse side of the product.

Key Features

  • Anti-Fouling Flashover & High Insulation Performance:With external insulation creepage distance ≥31mm/kV, equipped with anti-fouling flashover skirts and hydrophobic coatings, suitable for Class Ⅲ pollution areas. Partial discharge ≤5pC, passing 12kV/42kV/75kV power frequency/impulse withstand voltage tests, effectively reducing the risk of fouling flashover and ensuring long-term reliable operation in harsh environments.
  • Compact Design & Flexible Installation:Volume reduced by 40% compared to traditional oil-immersed transformers, weighing only 80kg, supporting vertical or horizontal installation. Compatible with mainstream medium-voltage switchgear like KYN28 and XGN15, simplifying substation layout and saving space costs.
  • Intelligent Monitoring Interface:Optional Modbus RTU digital output module for real-time voltage data transmission to monitoring systems, supporting remote condition monitoring and fault early warning. Compatible with smart grid architecture to facilitate digital upgrading of substations.
  • International Standard Compliance:Complies with IEC 60044-2 and GB/T 1207-2022 standards, certified by CE and RoHS. Insulation system meets UL94 V-0 flame retardant grade, with internationally recognized product quality and safety, suitable for domestic and foreign power engineering projects.

Technical parameter

  • Rated primary voltage: 20/√3 or 15/√3etc.
  • Technical standard accords with IEC 60044-2:2003 Part2 Instrument transformers-Part2: inductive voltage transformers

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!