• 4000kVA 10kV Electric Furnace Transformer(distribution transformer)
4000kVA 10kV Electric Furnace Transformer(distribution transformer)
discuss personally
Model
SFL11-4000/10
Basic info
Brand Vziman
Model NO. 4000KVA 10KV Electric Furnace Transformer
Rated capacity 4000KVA
Voltage grade 10KV
Series Electric Furnace Transformer
Product Detail

Product overview:

  •  Electric furnace transformer is a professional transformer planned according to various electric furnace working principle, load characteristics and operation characteristics.

  • It includes: arc furnace transformer for steelmaking, ladle refining furnace transformer, slag furnace transformer, mineral heat furnace transformer, power frequency furnace transformer and other communication furnace transformer and medium frequency induction furnace transformer, silicon carbide, graphitization furnace transformer and other DC furnace transformer.

  • Industrial furnace transformers are mainly divided into 3 types: resistance furnace transformers, arc furnace transformers and induction furnace transformers.

  • Hengfengyou electric furnace transformer production standards: one is according to the current provisions of China's standard planning and production of standard electric furnace transformer; The other is a new type of energy-saving furnace transformer developed and manufactured on the basis of Chinese standard furnace transformer.

Main applications:

  •  In metallurgical industry, it is used for smelting high quality alloy copper and iron alloy.

  •  In chemical industry, it is used to produce yellow phosphorus, calcium carbide, synthetic resin, etc.

  •  Used in the melting of cast steel and cast iron in the mechanical industry.

  •  High reliability of operation verification in more than 50 countries and regions around the world.

  • Products are mainly exported to East Asia, Central Asia, Southeast Asia, South America, North America and other markets and regions.

  • Implementation standard: IEC 60076 series.

Product advantagesl:

Leading technology:

  •  Large capacity, low loss, more energy saving, the actual measurement is better than GB and IEC standards.

  • High pressure copper tape winding technology, improve lightning resistance.

  •  Low voltage copper foil winding technology, high quality A class insulation material insulation, higher temperature resistance grade.

  •  Small magnetic leakage, high mechanical strength, strong short circuit resistance.

  •  Iron core 45° full oblique joint step laminated structure.

The shell:

  • Mitsubishi laser cutting machine and CNC punching, reducing, folding and other equipment to ensure the accuracy of processing.

  • ABB robot automatic welding, laser detection, to avoid leakage, qualified rate of 99.99998%.

  • Electrostatic spray treatment, 30 years of paint (coating corrosion resistance within 100h, hardness ≥0.4).

  • Fully sealed structure, maintenance-free and maintenance-free, normal operation life of more than 30 years.

The iron core:

  • The core material is high quality cold rolled grain oriented silicon steel sheet with mineral oxide insulation (from  Baowu Steel Group, China).

  • Minimize loss level, no-load current and noise by controlling the cutting and stacking process of silicon steel sheet.

  • The iron core is specially reinforced to ensure the transformer structure is firm during normal operation and transportation.

winding:

  • Low voltage winding is made of high quality copper foil, excellent insulation resistance.

  • The high voltage windings are usually made of insulated copper wire, using the patented technology of Hengfengyou Electric.

  • Very good resistance to radial stress caused by short circuit.

High quality material:

  •  Baowu Steel Group production of silicon steel sheet.

  • China produces high quality anaerobic copper.

  • CNPC (Kunlun Petroleum) High quality transformer oil (25#).

Product parameters:

image.png

image.png


Ordering instructions:

  •  Main parameters of transformer (voltage, capacity, loss and other main parameters).

  • Transformer operating environment (altitude, temperature, humidity, location, etc.).

  • Other customization requirements.

  •  Normal delivery period is 30 days.

  • Worldwide fast delivery.


What is an electric furnace transformer?

Furnace transformers are special - purpose transformers specifically used for electric arc furnaces, resistance furnaces, and other industrial electric furnaces. Its main function is to convert the high - voltage electrical energy provided by the power grid into low - voltage, high - current electrical energy suitable for the operation of electric furnaces. Furnace transformers are widely used in industries such as metallurgy, chemical engineering, and ceramics. The following are some key knowledge points of furnace transformers:

Definition and Characteristics:

  • Definition: A furnace transformer is a transformer specifically designed for electric furnaces, used to convert the high - voltage electrical energy of the power grid into low - voltage, high - current electrical energy suitable for the operation of electric furnaces.
    Characteristics:

  • High Current: Furnace transformers can provide high current to meet the high - power requirements of electric furnace heating.

  • Low Voltage: The output voltage is usually low to meet the working requirements of electric furnaces.

  • High Heat Resistance: Furnace transformers need to work in high - temperature environments, so they have good heat - resistant properties.

  • High Reliability: Furnace transformers need to operate continuously for a long time, so they have high reliability and a long service life.

  • High Efficiency: Furnace transformers usually have high efficiency to reduce energy loss and improve energy efficiency.

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!