Low frequency on-line UPs power supply (3phase in and 3phase out)

  • Low frequency on-line UPs power supply (3phase in and 3phase out)

Key attributes

Brand Switchgear parts
Model NO. Low frequency on-line UPs power supply (3phase in and 3phase out)
Rated frequency 50/60Hz
Input Voltage 380VAC
Capacity 15kVA
Series HBS

Product descriptions from the supplier

Description

Product application: Widely used in building lighting, road traffic lighting, power, industrial and mining enterprises, centralized server rooms, network management centers and computer centers, industrial automation equipment, etc.

The HBS series high-power three in three out intelligent uninterruptible power supply has a single machine capacity ranging from 6KVA to 400KVA. This product is a highly intelligent power supply product that integrates digitization, informatization, and networking. It uses high-speed microprocessor (MCU) and ASIC DDC control technology, and has strong capabilities
Large information collection system, signal processing system, monitoring system, and comprehensive protection system; Widely used in various electrical environments, such as high-rise buildings, road lighting, power, industrial and mining enterprises, network computer rooms, and other industries. Personalized design, friendly human-computer interaction function, intuitive Chinese and English color
The color display screen and status indicator monitoring interface are convenient for users to operate and use.

Product Features

Intelligent digital control technology:
Using high-speed microcontrollers and programmable logic devices to achieve circuit control, parameter setting, operation management, advanced self checking and self detection functions, it can perform self checking and fault analysis on all independent circuit connections on the circuit board. You can fully trust the digitally transformed sine wave voltage and the new solution for perfect operation to meet your actual needs. )
Efficient IGBT (Insulated Gate Bipolar Transistor) inverter technology:
Good high-speed switching characteristics of IGBT; Having working characteristics of high voltage and high current; Using voltage type drive, only a small control power is required. The fifth generation IGBT has lower saturation voltage drop, higher inverter efficiency, and higher reliability.
Flexible parallel technology:
Suitable for single machine, 1+1 parallel, and N+1 parallel redundancy systems with different loads.
Superior load characteristics:
Adopting three-phase completely independent PWM modulation and full bridge IGBT inverter technology, it fully meets the transition from 0 to 100% load without switching to bypass, and protects stable and reliable output.
Humanized 7-inch large LCD screen with Chinese and English color touch screen:
The 7-inch large screen LCD displays both Chinese and English menus, with a clear flow chart showing the running status and flexible human-machine dialogue function. The touch screen has event recording display and menu operations in both Chinese and English languages are available.
Complete protection function:
Multiple system protection and alarm functions, including input and output overvoltage protection, input surge protection, phase sequence protection, battery overcharge and overdischarge protection, output overload and short circuit protection, and high temperature protection.
High performance dynamic characteristics:
Multiple feedback controls such as instantaneous control and effective value are adopted to achieve high dynamic regulation and reduce voltage distortion.
6 pulses (optional 12 pulses)
The rectifier charger also adds an input harmonic filter to effectively suppress input harmonic pollution, improve the input power factor of the UPS power supply, and reduce the input harmonic current.
Intelligent battery management:
Intelligent battery charging, automatically adjusts the charging parameters of the battery according to the user's battery configuration, and performs equalization and float charging conversion, temperature compensation charging, discharge management based on the power supply environment to extend the battery's service life and reduce the burden on administrators.
Complete isolation technology
Input and output are completely isolated to reduce harmonic currents and direct interference from mains power.
Intelligent communication management:
The RS232 and RS485 communication ports truly realize multi-purpose communication and remote monitoring. The optional SNMP card enables remote monitoring and network management, and the optional dry contact interface uses passive contacts to monitor the status of UPS.

Technical Specifications

Model

HBS-6KS

HBS-10KS

HBS-15KS

HBS-20KS

HBS-30KS

HBS-40KS

HBS-50KS

HBS-60KS

HBS-80KS

HBS-100KS

HBS-120KS

HBS-150KS

HBS-200KS

HBS-250KS

HBS-300KS

HBS-400KS

Nominal Capacity (kVA)

6

10

15

20

30

40

50

60

80

100

120

150

200

250

300

400

Overall Working Mode and Principle

Online Power Supply, Static Bypass Switch (Uninterrupted Switching), Double Conversion Technology, Output Power Fully Isolated

Rectifier Working Mode

6-pulse (12-pulse Optional) Rectification

Input

 

Phase Number

Three Phase + N + G

Nominal Voltage

380VAC ± 25%

Nominal Frequency

50Hz ± 5%, 60Hz ± 5%

Voltage Harmonic Distortion

< 5%

Soft Start

0-100% 5S

Nominal Output DC Voltage

405VDC

Rated Power (KW, Cosφ=0.8)

Nominal Power × 0.8

Inverter

 

Phase Number

Three Phase + N + G

Nominal Voltage

380VAC ± 1% (Stable Load), 380VAC ± 5% (Load Fluctuation)

Nominal Frequency

50Hz ± 0.5%, 60Hz ± 0.5% (Battery Power Supply)

Frequency Stability

< ± 0.5% (Asynchronous)

Frequency Tracking Range

50Hz ± 5%

Crest Factor

3:1

Output Waveform

Sine Wave

Output Waveform Distortion

Linear Load < 3%; Non-linear Load < 5%

Dynamic Load Voltage Transient

< ± 5% (0 to 100% Load Change)

Instantaneous Recovery Time

< 10ms

Overload Capacity

125% 1min, 150% 1s

Inverter Efficiency

≥95% (100% Load)

Bypass

 

Phase Number

Three Phase + N + G

Nominal Voltage

380VAC ± 25%

Nominal Frequency

50Hz ± 5%, 60Hz ± 5%

Conversion Time

0ms (Inverter/Bypass)

Battery Charging

 

Battery Type

Maintenance-free Lead-acid Battery

Maximum Output Voltage

220vdc/405vdc

405VDC

Microcomputer-set Charging Current

1A~100A (Set According to Battery Capacity, Automatically Adjusted to 0.1C)

Quantity Unit

16 cells/30 cells 12V in series

30 cells/12V in series (180 cells/2V in series)

Charging Current

1A~100A (Automatically Adjusted to 0.1C According to Battery Capacity)

Nominal Battery Voltage

192VDC/360VDC

360VDC

Float Voltage

220VDC/405VDC

405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC)

Efficiency

> 80% (100% Load)

System

 

Computer Communication Interface

Standard RS232, Optional RS485, Dry Contact, SNMP Remote Monitoring Network Adapter

Operating Temperature

0-40℃

Relative Humidity (No Condensation)

30% - 90%

Operating Altitude (Maximum)

< 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 4000 Meters)

Cooling Method

Temperature-controlled Forced Air Cooling

Noise dB (1m from the Machine, Depending on Load and Temperature)

40-50

40-50

45-55

45-55

50-55

50-55

55-65

55-65

55-65

55-65

55-65

65-70

65-70

65-70

65-70

65-70

Cabinet Color

Black (Optional)

Input Cable

Bottom/Back

Easy Maintenance

Top/Left/Right Sides Can Be Opened

External Dimensions W×D×H(mm)

390×660×860

450×725×1035

710×720×1450

710×850×1500

1100×860×1680

1100×860×1680

1500×1160×1800

1500×1160×1800

1800×1250×1800

1800×1250×1800

1800×1250×1800

1800×1250×1800

1800×1250×1800

1800×1250×1800

1800×1250×1800

1800×1250×1800

Weight (kg)

150

212

260

352

396

485

568

635

903

951

1052

1355

1586

1850

2170

3155

Input and Output Devices

Terminal Block

FAQ
Q: What advantages does it have compared with high-frequency 3-phase online UPS?
A:

Compared with high-frequency UPS, it has obvious advantages: ① Higher reliability: Low-frequency transformer has strong overload capacity (supports 125% overload for 10 minutes) and anti-interference performance; ② Better stability: Suitable for harsh industrial environments with large voltage fluctuations and high harmonics; ③ Longer service life: Low-frequency components have lower heat generation and wear, service life up to 10-15 years; ④ Stronger load adaptability: Compatible with inductive, capacitive and resistive loads (such as motors, inverters).

Q: What is the core function and working principle of 3-phase in & 3-phase out low frequency on-line UPS?
A:

Its core function is to provide uninterrupted, stable and pure power for high-power industrial loads, with functions of voltage stabilization, harmonic filtering and surge protection. The working principle is double conversion (AC-DC-AC): when the mains is normal, it converts 3-phase AC to DC to charge the battery, then converts DC to stable 3-phase pure sine wave AC for load supply; when the mains fails, it switches to battery power supply with 0ms transfer time, ensuring no load shutdown.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.