Modular UPS emergency power supply

  • Modular UPS emergency power supply

Key attributes

Brand Switchgear parts
Model NO. Modular UPS emergency power supply
Rated frequency 50/60Hz
Output Voltage 380/400/415VAC
Input Voltage 380/400/415VAC
Capacity 150kVA
Series HBM

Product descriptions from the supplier

Description

Product application: This product has a wide range of applications and provides safe, stable, reliable, and environmentally friendly power protection for critical loads such as data centers, financial centers, government and enterprise data centers, medical education, etc.

HBM50-600KW is a new generation of three in three out modular UPS launched by our company. The product adopts digital control, modular design, and N+X parallel redundancy technology, which integrates the most advanced technological achievements in the fields of power electronics and automatic control. It is a benchmark product in the field of modular UPS.
The product capacity covers various power ranges between 50kW and 600kW, making it convenient for users to flexibly configure and gradually invest. It can run 4 parallel machines up to 2400kW.

Product features

Technical Specifications
All parts of the architecture are digitally controlled, with excellent performance and high system stability. It has self-protection and fault diagnosis capabilities, while also avoiding the risk of analog device failure, making the control system more stable and reliable.
Adopting advanced three-level technology, the overall efficiency of the machine is as high as 96%.
High power density design, 50KW single module size (W × D × H) 440 × 620 × 130mm.
The output can be connected to a completely unbalanced load. When the output is connected to an unbalanced load, the input current is balanced in three phases, which can balance the load of the three-phase power grid.
high reliability
The N+X parallel redundancy design ensures a system availability of 99.999% and an MTBF of over 250000 hours, meeting the high reliability requirements of critical loads on the power supply system; The flexible parallel redundancy setting allows the system to provide maximum output capacity.
Control system parallel redundancy, with control methods of decentralized control and centralized management; The centralized control unit is redundantly connected in parallel, and the failure of one of them does not affect the overall operation of the machine; The optimized distributed combiner cabinet ensures the safety of system parallel connection.
The centralized monitoring module has hot swappable function. When the monitoring module is unplugged, the system can work normally using centralized bypass power supply, which improves the power supply capacity of the bypass power supply.
EPO function, press the EPO button in emergency situations to shut down urgently; The EPO button is designed for protection and has a remote emergency shutdown (REPO) function to prevent accidental operation.
Convenient and flexible
Modular design, consisting of 1 to 12 modules connected in parallel, with a maximum power of 600kW. Users can gradually increase the number of modules with flexibility; Using hot swappable technology, modules can be added and removed online, achieving "zero" maintenance time.
The downtime for maintenance is short. The number of faulty modules is less than or equal to the number of redundant modules, and the downtime for maintenance is zero; The number of faulty modules is greater than the number of redundant UPS modules, and the downtime for maintenance shall not exceed 5 minutes.
The cabinet LCD touch color screen display provides rich UPS status information, warning information, fault information, etc; Single module LED display, users can understand the working status of the module through the module LED lights.
In case of emergency, UPS can switch to the maintenance bypass power supply, and maintenance personnel can safely perform online repairs.

intelligent design
The charging current can be set, and the user configured battery capacity and charging current can be set through the panel LCD to achieve automatic smooth switching between constant voltage charging mode, constant current charging mode, and float charging mode.
Intelligent charging method, adopting advanced two-stage three-stage charging method, can effectively balance the goals of fast charging and extending battery life, saving users' battery investment.
Provide a wide range of optional accessories, including isolation transformers, distribution panels, SNMP cards, relay dry connection cards, etc., to form a small to medium-sized distribution system.
Green Design
Adopting a 19 inch standard cabinet, it perfectly matches the application environment of the computer room and saves the usable area of the computer room.
Parallel sharing of batteries greatly reduces the number of battery configurations, allowing users to fully configure batteries based on backup time.
The number of external batteries is optional, and users can choose 30/32/34/36/38/40/42/44/46/48/50 cells (30-50 cells are optional) according to their needs.

Technical Specifications

Model

HBM90-30

HBM150-30

HBM300-30

Capacity

 

 

 

UPS Cabinet

30-90kVA

30-150KVA

30-300KVA

Power Module

30kVA

30kVA

30kVA

Input

 

 

 

Input Mode

Three-phase Four-wire + Ground

Rated Voltage

380/400V/415Vac

Voltage Range

208~478Vac

Frequency Range

40~70Hz

Power Factor

≥0.99

Bypass Range

380 upper limit: 25% (optional +10%, +15%, +20%)

 

400 upper limit: 20% (optional +10%, +15%)

 

415 upper limit: 15% (optional +10%)

 

Lower limit: -45% (optional -20%, -30%)

 

Bypass frequency protection range: ±10%

Input Current Harmonic

≤3% (100% Non-linear Load)

Output

 

Output Mode

Three-phase Four-wire + Ground

Rated Voltage

380/400V/415Vac

Power Factor

0.9 or 1

Voltage Accuracy

±1%

Output Frequency

 

Mains Mode

Synchronous with input; when mains frequency exceeds maximum ±10% (can be set to ±1%, ±2%, ±4%, ±5%), output frequency is 50×(±0.2%)Hz

Battery Mode

(50/60±0.2%)Hz

Load Crest Factor

3:1

Switching Time

Mains mode to bypass mode: 0ms (tracking); Mains mode to battery mode: 0ms

Overload Capacity

Load ≤110%, 60min; ≤125%, maintain 10min; ≤150% maintain 1min; ≥150% switch to bypass immediately

Output Voltage Harmonic

≤2% (100% Linear Load)

Efficiency

95% in Normal Mode

Communication Interface

RS232, RS485, 2 Intelligent Slot (Smart Card Slot), Dry Contact

Battery

 

Battery Voltage

±192V±204V±216V±228V±240V DC; (32, 34, 36, 38, 40 cells optional)

Charging Current

 

UPS Cabinet

30A Max.

50A Max.

100A Max.

Power Module

10A Max.

10A Max.

10A Max.

Working Environment

 

 

 

Working Temperature

0℃ ~ 40℃

0℃ ~ 40℃

0℃ ~ 40℃

Relative Humidity

0 ~ 95% non condensing

Storage Temperature

-25℃ ~ 55℃

Altitude

< 1500m

< 1500m

< 1500m

Physical Characteristics

 

Appearance Dimensions (D×W×H) mm

 

 

 

Cabinet

840 x 600 x 1400

840 x 600 x 1400

1100 x 600 x 2000

Module

580 x 443 x131

580 x 443 x131

580 x 443 x131

Weight (Net Weight) Kg

 

 

 

Cabinet

158

170

305

Module

30K module, 33.5KGS

Execution Standard

CE,EN/IEC 62040-2, EN/IEC 62040-1-1, YD/T1095-2008

 

Model

HBM300-50

HBM400-50

HBM500-50

HBM600-50

Capacity

 

 

 

 

Cabinet

50-300KW

50-400KW

50-500KW

50-600KW

Module

50KW

50KW

50KW

50KW

Maximum Number of Modules

6

8

10

12

Input

 

Main Path Input

 

Rated Input Voltage (Vac)

380/400/415

Input Voltage Range (Vac)

138 ~ 485Vac

Wiring Mode

Three-phase Five-wire

Input Frequency Range (Hz)

40-70

Input Power Factor

≥0.99

Input Current Harmonic (THDi)

≤3% (100% Linear Load)

Bypass Input

 

Rated Input Voltage (Vac)

380/400/415

Input Voltage Range (Vac)

220 upper limit: 25% (optional +10%, +15%, +20%) 230 upper limit: 20% (optional +10%, +15%) 240 upper limit: 15% (optional +10%) lower limit: -45% (optional -10%, -20%, -30%)

Wiring Mode

Three-phase Five-wire

Bypass Synchronous Tracking Range (Hz)

±10%

Generator Input

Supported

Power Walking In

Supported

Bypass Reverse Feeding

Supported

Output

 

Voltage (Vac)

380/400/415±1%

Power Factor

1

Frequency (Hz)

 

Mains Mode

±1%/±2%/±4%/±5%/±10% (Configurable)

Battery Mode

(50/60±0.1%)Hz

Waveform

Sine Wave

Current Crest Ratio

3:1

Output Voltage Harmonic (THDV)

≤2% (100% Linear Load); ≤3% (100% Non-linear Load)

Switching Time (ms)

0

Overall Efficiency (%)

96

Overload Capacity

110% load, transfer to bypass after 60min; 125% load, transfer to bypass after 10min; 150% load, transfer to bypass after 1min

Battery

 

Maximum Module Charging Current (A)

20

Battery Voltage

30~50 cells optional, default 36 cells; optional voltages: ±180V/±192V/±204V/±216V/±228V/±240V/±252/±264/±276/±288/±300Vdc (30/32/34/36/38/40/42/44/46/48/50 cells)

Environment

 

Working Temperature

0℃ ~ 40℃

Storage Temperature

—25℃ ~ 55℃

Humidity Range

0 ~ 95% (Non-condensing)

Working Altitude

< 1500m (Derate for use above 1500m)

Noise (1m Distance)

<68dB

<70dB

<70dB

<70dB

Other Functions

 

 

 

 

Protection Functions

Short circuit, overload, over temperature, output over voltage, battery under voltage, fan fault alarm, bypass reverse feeding, lightning protection

Alarm Functions

Mains abnormality, overload, UPS fault, battery under voltage and other multiple alarm functions

Communication Functions

CAN, RS485, Network Interface, Dry Contact, Parallel Interface, LBS Interface, Smart Card Slot, Temperature Sensor Interface

Mechanical Characteristics

 

Dimensions (W×D×H)

 

Cabinet (mm)

600×850×2000

600×850×2000 (Standard); 1200×850×2000 (Fully Loaded)

1200×850×2000

1200×850×2000

Module (mm)

440×620×130

Net Weight

 

Cabinet (kg)

260

280/600

645

720

Module (kg)

32

Execution Standard

YD/T 2165-2010

FAQ
Q: What advantages does the HBM series modular UPS have compared with traditional tower UPS?
A:

Compared with traditional tower UPS, it has obvious advantages: ① Flexible expansion: Capacity can be increased by adding modules on demand, avoiding initial over-investment; ② High reliability: N+X redundancy design eliminates single-point failure, and hot-swappable modules reduce MTTR (mean time to repair) to minutes; ③ Energy saving: AC-AC efficiency up to 97%, ECO mode efficiency up to 99%; ④ Space-saving: High power density design (e.g., 60kW module in 3U space) saves installation space; ⑤ Easy maintenance: Independent module design simplifies fault diagnosis and replacement.

Q: What is the core function and working principle of the HBM series modular UPS?
A:

 Its core function is to provide high-reliability uninterrupted power supply for critical loads, with flexible capacity expansion and low-maintenance advantages. The working principle is based on N+X redundant parallel technology: each power module works independently and shares the load evenly; when the mains is normal, it stabilizes voltage, filters harmonics and supplies power to loads while charging batteries; when the mains fails, it switches to battery power supply with 0ms conversion time. Failed modules can be hot-swapped without shutting down the system, ensuring 99.999% system availability.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.