• General Protection Device
General Protection Device
discuss personally
Model
RWH-151
Basic info
Brand RW Energy
Model NO. General Protection Device
Rated voltage 230V ±20%
Rated frequency 50/60Hz
Electric energy consumption ≤5W
Series RWH-15
Product Detail

Description

General Protection Device is a microprocessor as the core, combined with modern electronic technology, computer technology, communication technology, to realize the power system fault detection, protection control and operation monitoring function of intelligent equipment. As the key line of defense for the safe and stable operation of the power system, it replaces the traditional electromagnetic protection device and significantly improves the reliability, sensitivity and speed of protection.

The device is mainly composed of data acquisition system, microprocessor unit, input/output interface, communication module and power module. When working, the data acquisition system collects analog signals such as current and voltage in real time, and transmits them to the microprocessor after analog-to-digital conversion; the microprocessor analyzes and calculates the data according to preset protection algorithms and logic programs, and determines whether a fault or abnormality occurs in the power system; once a fault is detected, it quickly drives the circuit breaker to trip and removes the faulty equipment through the output interface and uploads the fault information to the monitoring center through the communication module. Upload the fault information to the monitoring center through the communication module

Support communication protocols: IEC 60870-5-101 IEC 60870-5-104 Modbus DNP3.0

Main function introduction

1. Protection relay functions:

1) 49 Thermal Overload,

2) 50 Three-section of Overcurrent (Ph.OC) ,

3) 50G/N/SEF Sensitive Earth Fault (SEF),

4) 27/59 Under/Over Voltage (Ph.OV/Ph.UV),

5) 51C Cold load pickup (Cold load).

2. Supervision functions: 

1) 60CTS CT Supervision,

2) 60VTS VT Supervision,

3. Control functions:

1) 86 Lockout,

2) 79 Auto reclose,.

3) circuit-breaker control,

4. Monitoring Functions:

1) Primary currents for Phases and Zero sequence current,

2) Primary PT Voltage,

3) Frequency,

4) Binary Input/Output status,

5) Trip circuit healthy/failure,

6) Time and date, 

7) Fault records,

8) Event records.

5. Communication functions:

a.  Communication interface: RS485X1,RJ45X1

b. Communication protocol: IEC60870-5-101; IEC60870-5-104; DNP3.0;  Modbus-RTU

c. PC software: RWK381HB-V2.1.3,The address of the information body can be edited and queried by PC software,

d. SCADA system: SCADA systems that support the four protocols shown in "b.”.

6. Data Storage functions:

1) Event Records,

2) Fault Records,

3) Measurands.

7. remote signaling remote measuring, remote controlling function can be customized address.

Technology parameters

paramete.png

Device structure

RWH-15-Model.png

RWH-15端子定义图-Model.png

微机安装.png

About customization

The following optional functions are available: GPRS communication module. Upgrade SMS Function.

For detailed customization, please contact the salesman.

 

Q: What is the function of Microcomputer protection device?

A: The microcomputer protection device is mainly used to protect the electrical equipment in the switchgear. It can monitor electrical parameters such as current and voltage in real time. When there is overcurrent, overvoltage, undervoltage and other fault conditions, the rapid response, such as tripping to cut off the circuit, to prevent equipment damage, to ensure the safe and stable operation of the power system.

Q: What are its advantages over traditional protection devices?

A: The precision of The microcomputer protection device is higher, and the electric quantity can be measured accurately. It has the function of self-diagnosis, can find its own fault in time for maintenance. Moreover, the protection parameters can be set flexibly to adapt to different power system requirements. It can also realize remote communication and facilitate remote monitoring and operation, which is difficult to do with traditional protection devices.

 

Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High Voltage Electrical Apparatus/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Documents
Restricted.
General Protection Device
Manual English
Consulting
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!