• UniGear ZS1  Air-insulated switchgear for power application
UniGear ZS1 Air-insulated switchgear for power application
discuss personally
Model
UniGear ZS1-17.5
UniGear ZS1-24
UniGear ZS1-12
Basic info
Brand ABB
Model NO. UniGear ZS1 Air-insulated switchgear for power application
Rated voltage 17.5kV
Rated frequency 50/60Hz
Series UniGear ZS1
Product Detail

Description:

UniGear ZS1 is the ABB mainlineglobal switchgear for primary distribution up to 24 kV, 4 000 A,63 kA.The switchgear is manufacturedworldwide and there are more than 700 000 panels currently installed.

UniGear ZS1 is used to distribute electric power in a variety of demanding applications such as on off shore platforms, in container or cruise ships, in mines as well as in utility substations, power plants or chemical plants.UniGear ZS1 is available as a single busbar, double busbar, back to back or double level solution.

Features

  • Standards: IEC, CSA, GOST, GB/DL.
  • Most of panels classified as LSC2B, PM *.
  • Accessibility type: A.
  • Internal arc class: FLR.
  • Highly customized versions available.
  • Switchgear can be back to wall installed.

Safety

  • Fully type tested according to IEC 62271-200.
  • Fitted with safety interlocks.
  • Circuit breaker racking with closed doors.

UniGear ZS1 panel variants have the most common classification LSC2B, PM. Check other panel variants and their LSC classification in catalogue 1VCP000138.

Switching devices

  • Vacuum circuit breaker with spring actuator.
  • Vacuum circuit breaker with magnetic actuator.
  • SF6 circuit breaker with spring actuator.
  • Vacuum contactor.
  • Switch disconnector.

Current and voltage measurement:

  • Current and voltage sensors.
  • Conventional current and voltage instrument transformers .

Protection and control:

  • Relion® protection and control relays.

Optionally available with:

  • Optical arc fault protection 
  • Ultra Fast Earthing Switch UFES
  • Surge arresters
  • Is-limiter, advanced fault current limiter
  • Smart solutions

Technical parameters

 1.With installed gas exhaust duct 2.Depending on rated feeder current  3. 2 089 – 2 154 mm for 63 kA 4) 42 kV (63 kA version; GB/DL)
 Note: 1 250 A - 40 kA  available at 650 mm panel

Structure diagram

Know your supplier
ABB
As an authorized distributor of ABB products, we take great pride in our partnership.
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus
Business Type
Sales
Highest Annual Export (USD)
$580000000
Professional Experience
11 years
Workplace
20000m²
占位
占位
Documents
Public.
UniGear ZS1 Air-insulated switchgear for power application
White paper English
PDF
FAQ
Q: What are the key features of ABB’s medium voltage switchgear products?
A:
ABB‘s primary medium voltage switchgear products are designed to connect and protect the evolving grid. They feature robust construction, advanced safety mechanisms, high reliability, and ease of maintenance. They are designed to handle high electrical loads and provide efficient power distribution with minimal losses.
Q: What standards and certifications that ABB’s medium voltage switchgear products comply with?
A:
Our medium voltage switchgear products comply with international standards such as IEC 62271, GOST, GB/DL. They are also certified by leading industry bodies to ensure the highest levels of safety and performance. ABB also offers medium voltage switchgear products for ANSI standards.
Related Products
Related Knowledges
Sharing of Transformer Concepts and Terminology
Sharing of Transformer Concepts and Terminology
Sharing of Transformer Concepts and TerminologyThe zero-mode impedance of a load is infinite, and its line-mode impedance is also extremely large, approximately 100 times that of the line-mode impedance of the line.The capacitance to ground of a cable is 25-50 times that of an overhead line.The free oscillation frequency of transient capacitive current: 300-1500Hz for overhead lines and 1500-3000Hz for cables.Performance requirements for an external grounding transformer: Under normal power supp
Edwiin
07/28/2025
What is a traveling wave?
What is a traveling wave?
Traveling Waves on LinesA traveling wave on a line refers to a voltage or current wave propagating along the line; it is also defined as a voltage or current signal traveling along a conductor.Steady-state traveling wave: A traveling wave propagating along the line during the normal operation of a system, generated by the system's power supply.Transient traveling wave: A suddenly occurring traveling wave during system operation, caused by ground faults, short-circuit faults, wire breakages, swit
Leon
07/28/2025
Example of Process Improvement for Enhancing Consistency of Small - Batch High - Temperature Special Transformers
Example of Process Improvement for Enhancing Consistency of Small - Batch High - Temperature Special Transformers
Given the lack of manufacturers for such transformers on the market, we design them in - house. We provide technical specs to partners, specifying materials like high - temp enameled wires.Electrical signals from downhole logging tools, transmitted via these transformers, impact formation - to - surface signal reliability. Thus, improving transformer consistency boosts signal uniformity, enhancing logging tool accuracy and our market competitiveness.Our common signal transformers are EI - type,
Vziman
07/28/2025
Analysis of the Process of Transformer Oil of Specialty Transformers Being Contaminated by Microorganisms and the Treatment Measures
Analysis of the Process of Transformer Oil of Specialty Transformers Being Contaminated by Microorganisms and the Treatment Measures
1 OverviewCases of transformer oil contaminated by microorganisms have been reported both domestically and internationally. Individual transformer manufacturers, user units, and research institutions have conducted specialized studies, but all focused on power transformers. This paper targets specialty transformers for specific applications (e.g., rectifier transformers for graphitization furnaces, submerged arc furnace transformers), exploring the process of microbial contamination of their tra
Rockwell
07/28/2025
How is the contradiction between the small grounding residual current and the neutral point displacement voltage exceeding the standard resolved?
How is the contradiction between the small grounding residual current and the neutral point displacement voltage exceeding the standard resolved?
Contradiction PointsIn automatic tracking arc suppression coils, the adjustment precision is high, the residual current is small, and the operation is close to the resonance point.In an automatic tracking arc suppression coil grounding system, two factors must be considered: Under normal operating conditions, the long-term voltage displacement of the neutral point should not exceed 15% of the system's nominal phase voltage; In the case of a ground fault, the grounding residual current should be
Edwiin
07/28/2025
Power Supply Design of the Group Testing Device for Special Transformers in Electrified Railways
Power Supply Design of the Group Testing Device for Special Transformers in Electrified Railways
1 Hardware Design of Tester Power SupplyThis device uses a standard small - signal generating device to generate small - current signals with the required frequency and phase angle. Then, through the amplifying circuit and phase - modulating circuit, the working power supply is generated.1.1 Power Frequency Sine Wave Small - Current Signal Generating DeviceThe sine wave generating circuit is mainly composed of the waveform generating chip MAX038 produced by MAXIM Corporation of the United States
Ron
07/28/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!