SVR - High Voltage Feed Voltage Regulating Transformer(distribution transformer)
discuss personally
Model
SZ11-35
Basic info
Brand Vziman
Model NO. SVR - High Voltage Feed Voltage Regulating Transformer
Voltage grade 35KV
Series SVR - High Voltage Feed Voltage Regulating Transformer
Product Detail

Product advantages:

  • The SVR series automatic voltage regulating and stabilizing transformers for high-voltage feed lines track changes in line voltage, automatically collect and control signals from the circuit, and automatically adjust the transformer ratio of the device to ensure stable output voltage.

  • The voltage regulating transformer produced by WONE can automatically adjust the input voltage within a range of ± 20%, suitable for lines with high voltage fluctuations or voltage drops. This type of feeder voltage regulator is installed in series at the middle and rear of 3KV-38KV lines to adjust the line voltage within a certain range, ensuring the power supply voltage of users. 

  • The SVR series feeder automatic voltage regulator produced by WONE is also suitable for substations where the main transformer does not have voltage regulation capability. This type of voltage regulator is installed on the outlet side of the substation transformer to ensure the voltage of the busbar on the outlet side.

  • The SVR series feeder automatic voltage regulator is suitable for high or low voltage unstable places such as rural power grids, tunnels, oil fields, mining areas, chemical industries, substations, etc. At present, this product has been sold to developing countries such as Central Asia, Africa, Southeast Asia, and South America.
    Ordering instructions:

  • Main parameters of transformer (voltage, capacity, loss and other main parameters).

  • Transformer operating environment (altitude, temperature, humidity, location, etc.).

  • Other customization requirements (tap switch, color, oil pillow, etc.).

  • The minimum order quantity is 1 sets, worldwide delivery within 7 days.

  • Normal delivery period of 30 days, worldwide fast delivery.

What is SVR?

SVR (Static Var Regulator) is a device used to regulate reactive power and voltage in power systems. It maintains the stability of the system voltage by dynamically adjusting the output of reactive power, thus improving power quality and the operating efficiency of the system. The following are some detailed knowledge points related to SVR:

Basic ConceptsL:

  • Reactive Power:
    Reactive power refers to the power exchanged between inductive and capacitive elements and the power source in an AC circuit. Reactive power does not consume energy, but it affects the voltage level and power factor of the system.

  • SVR:The static var regulator is a device capable of dynamically adjusting reactive power, which is used to maintain the voltage stability of the power system.

Working Principles:

  • Reactive Power Compensation:
    SVR regulates the voltage level of the system by injecting or absorbing reactive power into the system. When the system voltage drops, SVR injects reactive power; when the system voltage rises, SVR absorbs reactive power.

  • Dynamic Response:
    SVR can quickly respond to voltage fluctuations in the system, providing immediate reactive power support to ensure voltage stability.

  • Control Mode:
    SVR usually adopts closed-loop control. It monitors the system voltage and current through sensors, and the controller adjusts the output of reactive power according to the monitored data.



Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!