TM/TMY Series Copper Busbar

  • TM/TMY Series Copper Busbar

Key attributes

Brand Wone Store
Model NO. Customized Copper-aluminum Composite Strip/Bar/Plate EXW/FOB/CIF
Thickness 2.24-50mm
Width 16-400mm
Series TM/TMY

Product descriptions from the supplier

Description

Product application

Product application: Apply to electrical engineering like high/low voltage clectrical appliances, switch contact, power distribution equipment, bus duct and larg current electrolysis refining project like mental smelting petrochemical.

Operative Norm

GB/T5585.1-2005 Electrical copper busbar.

Type and Chemical composition

1721696966589_修复后.png

  • Section shapes of copper busbar: circular bead, round edge, all round edge.

    1721697362146.png

  • a-Thickness is the narrow side dimension mm; b-Thickness is width dimension mm; r -Rounded Corenur Rounded edge radius mm.

Thickness deviation 

1721697772702_修复后.png


Width deviation
1721697614092_修复后.png

Physical property

1721697834041_修复后.png

Q: What kind of material is copper bus? 

A: Copper busbar is a high-current conductive product made of copper. It is usually rectangular or circular long strip, with high purity copper material, copper conductivity is good, which makes the copper bus can carry a large current. 

Q: Where is the copper bus mainly used? 

A: It is widely used in power facilities such as substations and distribution rooms. For example, in substations, it is used to connect transformers, switchgear and other equipment, which can effectively distribute and transmit electric energy. It is also indispensable in the electrical system of large factories, which can distribute electrical energy to various workshops or large equipment. 

Q: What are the advantages of copper bus bars?

A: It has many advantages, first of all, strong conductivity, can reduce power loss. Secondly, its mechanical strength is relatively high, and it can withstand certain mechanical stresses. Moreover, the processing performance of the copper busbar is good, and the processing operations such as cutting and bending can be carried out according to the actual needs.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • How Much Current Can a 0.75 mm² Copper Wire Carry?
    The current-carrying capacity of a 0.75 mm² copper wire depends on several factors, including the operating environment, type of insulation, whether the wire is installed in conduit, and the number of wires. Here are some common scenarios and their corresponding current ratings:1. Household PVC-Insulated Copper WireAccording to general experience and standards, the safe current-carrying capacity of household PVC-insulated copper wire is as follows:Safe Current Rating: 6 A per square millimeter.S
    11/06/2024
  • Can Copper PVC Cable Be Used to Connect to Air Terminals in Lightning Protection Systems?
    In lightning protection systems, the selection of conductive materials and types for connecting air terminals (lightning rods) is very important. Using copper PVC cable to connect to air terminals is not the best choice, and the main reasons are as follows:1. Conductivity Copper Wire: Copper is an excellent conductor and can effectively carry lightning current. PVC Insulation Layer: The PVC insulation layer may melt or burn due to high temperatures during a lightning strike, affecting conductivi
    11/04/2024
  • Is the resistance higher in solid or stranded (copper) wire?
    Solid wire and stranded wire are both commonly used types of conductors, each with their own advantages and disadvantages. When discussing resistance, we need to consider factors such as the total cross-sectional area, material, temperature, and the geometric shape of the conductor. Below is some basic information about the resistance characteristics of solid wire and stranded wire:Solid WireSolid wire is made from a single piece of metal conductor without any internal gaps or seams. This type o
    10/23/2024
  • What is meant by burning of wire? What happened in wire of copper or silver and we can't use it again?
    Meaning and Causes of Wire BurnoutWire burning out typically refers to a situation where wires lose their ability to function normally due to changes in their physical or chemical properties caused by overheating or other reasons. This may involve the melting of wire insulation, damage to conductors, or failure of connection points, among other issues.The specific situation that led to the wire burning out1.Overload UseWhen the current carried by a wire exceeds its design capacity, it can cause
    10/21/2024
  • How do you know the maximum number of groups of coils in a three-phase electric motor?
    The maximum number of coil groups in a three-phase motor can be determined by considering the relationship between the number of poles, phases, and slot positions in the motor. Here's how to calculate it:Pole and Slot Count: In a three-phase motor, the slot count is usually a multiple of 3 because each phase has its own coil group evenly distributed around the stator. The relationship between the slot count (S) and the pole count (P) is directly related through the three-phase winding mode: S =
    10/05/2024
  • What type of wire is typically used for making electric cables?
    Electric cables are composed of one or more wires enclosed in a protective covering. The choice of wire material depends on several factors including conductivity, cost, flexibility, strength, and resistance to corrosion. The most commonly used types of wire for making electric cables include:Copper (Cu) High Conductivity: Copper has excellent electrical conductivity, second only to silver among common metals. Good Flexibility: Copper is relatively soft and ductile, which makes it easy to work w
    09/30/2024
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.