How Much Current Can a 0.75 mm² Copper Wire Carry?

Encyclopedia
Field: Encyclopedia
0
China

The current-carrying capacity of a 0.75 mm² copper wire depends on several factors, including the operating environment, type of insulation, whether the wire is installed in conduit, and the number of wires. Here are some common scenarios and their corresponding current ratings:

1. Household PVC-Insulated Copper Wire

According to general experience and standards, the safe current-carrying capacity of household PVC-insulated copper wire is as follows:

Safe Current Rating: 6 A per square millimeter.

Safe Current Rating for 0.75 mm² Copper Wire:

0.75mm2×6 A/mm2=4.5A

2. Current Ratings Under Different Conditions

Single Conductor in Free Air:

Safe current rating: approximately 6.75 A.

Installed in Conduit (Multiple Conductors):

Reduce the rating to 90% of the free air value:

6.75 A×0.9=6.075 A

For normal operating conditions, use 70% of the maximum current:

6.075 A×0.7=4.2525 A

3. Specific Applications

Residential Use:

0.75 mm² copper wire is typically used for lighting circuits and small appliances, with a safe current rating of 4.5 A.

Industrial and Commercial Use:

In more demanding environments, it is advisable to use a lower safe current rating to ensure long-term stable operation.

4. Power Calculation

At 220V:

Maximum Power:

P=I×V=6.75A×220V=1485 W

Safe Operating Power:

P=4.5 A×220 V=990 W

Summary

The safe current-carrying capacity of a 0.75 mm² copper wire is generally 4.5 A. However, under specific conditions (such as a single conductor in free air), it can carry up to 6.75 A. To ensure safety and long-term stable operation, it is recommended to use 4.5 A as the safe current rating in practical applications.

Give a tip and encourage the author!

Recommended

Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
01/30/2026
Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Related Products
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.