• WDJB-II Single-phase Relay Protection Tester ( single-chip microcomputer)
  • WDJB-II Single-phase Relay Protection Tester ( single-chip microcomputer)
  • WDJB-II Single-phase Relay Protection Tester ( single-chip microcomputer)
WDJB-II Single-phase Relay Protection Tester ( single-chip microcomputer)
$3000.00
Model
PRT-25/0.1E
RPT-50/0.1E
RPT-100/0.1
Basic info
Brand Wone
Model NO. WDJB-II Single-phase Relay Protection Tester ( single-chip microcomputer)
Rated voltage AC220V+10%
Rated frequency 50Hz
Rated Output Rating 0~25A/50V
Series WDJB-II
Product Detail

Description

WDJB-II relay protection tester the AC and DC voltage and current sources inside the instrument adopt the latest power supply technology, which makes the instrument reach the domestic advanced level in circuit design, device selection, panel layout and internal structure design. The instrument has the advantages of complete functions, excellent selection of materials, clear test item data, and simple operation. It is the first choice for power relay protection departments.

Feature

  • Measuring relay: It can measure the starting value, return value and return coefficient of current and voltage relays.

  • Time relay: It can measure the start value, return value and its action time.

  • Intermediate relay: It can measure the starting value, return value, holding value and action time of various intermediate relays with starting coil and holding coil.

  • Reclosing relay: Capacitor charging test, charging time, reclosing time and intermediate component tests can be performed.

  • Differential relay: DC excitation test, braking characteristic test and volt-ampere characteristic test can be carried out.

  • various other uncommon relays.

Specifications

Working power supply AC220V+10% 50Hz
Working environment: Temperature: -1040
Humidity ≤85%
Atmospheric pressure  86106Kpa
 AC voltage  0 ~ 250V/3A
AC current 0100A/12V/ 050A/25V/  025A/50V
DC voltage 0320V/3A
 DC current 020A/25V
fixed value output  DC24V DC48V DC110V DC220V
current, voltmeter 41/2 digits
Digital millisecond meter  099.9999s


Know your supplier
Wone
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!