How does the flow of electricity through the ground cause a fire hazard?

Encyclopedia
10/14/2024

Electric current passing through the ground (i.e., through a grounding path) can pose a fire hazard mainly because the current generates heat when traveling through unintended paths. This heat can potentially ignite flammable materials nearby. Below are some mechanisms by which electric current passing through the ground can cause a fire hazard:

1. Overcurrent 

  • Short Circuit: If the current travels through a path not designed to carry the intended current strength (such as the ground), it can result in a short circuit. A short circuit leads to a significant amount of current flowing through, generating a large amount of heat.

  • Overload : Even without a short circuit, if the ground becomes an additional path for the current, it can lead to an overload situation, thereby producing excessive heat.

2. Arc Flash

  • Arcs: When the current travels through the ground or other non-conductive material (such as air), it can produce arcs. Arcs can release a large amount of energy sufficient to ignite nearby flammable materials.

  • Sparks: Sparks generated by current passing through the ground can also ignite flammable materials.

3. Corrosion and Physical Damage

  • Corrosion: If there are metallic substances in the ground (such as pipes or rebar), the current can cause corrosion of these metals. Corrosion can weaken the metal structure and generate heat.

  • Physical Damage : The passage of current through the ground can cause physical damage to the ground material, such as charring or melting, increasing the risk of fire.

4. Resistance Heating

  • Poor Contact: If the contact points where the current passes through the ground are poor (for example, if the contact surfaces are dirty or corroded), these points become high-resistance areas. High-resistance areas generate a lot of heat.

  • Soil Resistivity: The resistivity of the soil also affects the current density passing through the ground. High-resistivity soils can generate more localized heat when current flows through them.

5. Flammability of Materials

Flammable Materials: If there are flammable materials around the ground (such as wood chips, paper, chemicals), even small-scale electrical sparks can be enough to start a fire.

6. Equipment Failure

  • Insulation Damage: If the insulation of electrical equipment or cables is damaged, the current can leak to the ground, leading to overheating and potentially causing a fire.

  • Design Defects: If the electrical system is improperly designed, such as lacking adequate grounding protection, it can lead to current traveling through the ground rather than through the intended path.

Preventive Measures 

To prevent fire hazards caused by electric current passing through the ground, the following measures can be taken:

  • Proper Grounding : Ensure all electrical equipment has a good grounding connection.

  • Regular Inspections: Regularly inspect electrical equipment and cables to ensure they are in good condition and free from damage or aging.

  • Use Residual Current Devices : Install residual current devices (RCDs) to quickly cut off the power supply when there is a current leakage.

  • Training and Education: Raise awareness among employees about electrical safety and understand how to avoid electrical fires.

  • Comply with Regulations: Adhere to national and regional electrical safety standards and regulations.

By implementing these measures, the risk of fires caused by electric current passing through the ground can be significantly reduced.


Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
Frequency division method for measuring grid-to-ground insulation parameters
Frequency division method for measuring grid-to-ground insulation parameters
The frequency division method enables the measurement of grid-to-ground parameters by injecting a current signal of a different frequency into the open delta side of the potential transformer (PT).This method is applicable to ungrounded systems; however, when measuring the grid-to-ground parameters of a system where the neutral point is grounded via an arc suppression coil, the arc suppression coil must be disconnected from operation beforehand. Its measurement principle is shown in Figure 1.As
Leon
07/25/2025
The insulation parameters of the power grid to ground are measured by the tuning method
The insulation parameters of the power grid to ground are measured by the tuning method
The tuning method is suitable for measuring the ground parameters of systems where the neutral point is grounded via an arc suppression coil, but not applicable to ungrounded neutral point systems. Its measurement principle involves injecting a current signal with continuously varying frequency from the secondary side of the Potential Transformer (PT), measuring the returned voltage signal, and identifying the system's resonant frequency.During the frequency sweeping process, each injected heter
Leon
07/25/2025
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
In an arc - suppression coil grounding system, the rising speed of the zero - sequence voltage is greatly affected by the value of the transition resistance at the grounding point. The larger the transition resistance at the grounding point, the slower the rising speed of the zero - sequence voltage.In an ungrounded system, the transition resistance at the grounding point has basically no impact on the rising speed of the zero - sequence voltage.Simulation Analysis: Arc - suppression Coil Ground
Leon
07/24/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!