What is the difference between a lightning impulse current and an impulse discharge current?

Encyclopedia
11/27/2024

Lightning surge current  and impulse discharge current are two different electrical phenomena, each with distinct characteristics, sources, and applications. Below is a detailed explanation of the differences between these two types of currents:

Lightning Surge Current 

Definition:

Lightning surge current refers to the instantaneous large current caused by lightning. When lightning strikes the ground or a building, it generates a massive current pulse, which is the lightning surge current.

Characteristics:

  • High Amplitude: The peak value of lightning surge current can reach hundreds of thousands of amperes.

  • Fast Rise Time: The rise time of lightning surge current is very short, typically reaching its peak within a few microseconds.

  • Short Duration: The duration of lightning surge current is also very short, generally ranging from tens of microseconds to hundreds of microseconds.

Source:

Lightning surge current primarily originates from natural lightning activity.

Impact:

  • Damage to Electrical Equipment: Lightning surge current can cause damage to electrical equipment, including insulation breakdown, overheating, and explosions.

  • Communication Interference: Lightning surge current can interfere with communication lines, leading to data transmission errors or interruptions.

  • Safety Risks: Lightning surge current poses a threat to personal safety, potentially causing electric shock accidents.

Protection Measures:

  • Lightning Rods: Installing lightning rods can safely guide lightning current into the ground.

  • Surge Protective Devices (SPDs): Using surge protective devices (SPDs) can absorb or limit lightning surge current, protecting electrical equipment.

  • Grounding Systems: A well-designed grounding system can effectively dissipate lightning surge current, reducing damage.

Impulse Discharge Current 

Definition:

Impulse discharge current refers to the instantaneous large current caused by overvoltage or insulation breakdown in electrical equipment or systems. This type of current typically occurs in high-voltage systems, such as high-voltage transmission lines and substations.

Characteristics:

  • High Amplitude: The peak value of impulse discharge current is usually high, but typically lower than that of lightning surge current.

  • Relatively Fast Rise Time: The rise time of impulse discharge current is relatively fast, but generally longer than that of lightning surge current.

  • Short Duration: The duration of impulse discharge current is also short, but generally longer than that of lightning surge current.

Source:

Impulse discharge current primarily originates from overvoltage events in electrical equipment, such as operational overvoltages and insulation breakdown.

Impact:

  • Damage to Electrical Equipment: Impulse discharge current can cause damage to electrical equipment, including insulation breakdown, overheating, and explosions.

  • System Failures: Impulse discharge current can cause failures in electrical systems, leading to power outages or equipment shutdowns.

  • Safety Risks: Impulse discharge current poses a threat to personal safety, potentially causing electric shock accidents.

Protection Measures:

  • Overvoltage Protection Devices: Using overvoltage protection devices (such as surge arresters and metal oxide varistors) can absorb or limit overvoltage, preventing the generation of impulse discharge current.

  • Enhanced Insulation: Strengthening the insulation of electrical equipment can improve its ability to withstand overvoltage.

  • Regular Testing: Regularly testing the insulation condition of electrical equipment can help identify and repair potential insulation issues.

Summary

Lightning Surge Current primarily originates from natural lightning activity. It has extremely high amplitude, very fast rise time, and short duration, posing significant threats to electrical equipment and personal safety.

Impulse Discharge Current primarily originates from overvoltage events in electrical equipment. It has relatively high amplitude, faster rise time compared to lightning surge current, and shorter duration compared to lightning surge current, and similarly has a significant impact on electrical equipment and systems.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
Frequency division method for measuring grid-to-ground insulation parameters
Frequency division method for measuring grid-to-ground insulation parameters
The frequency division method enables the measurement of grid-to-ground parameters by injecting a current signal of a different frequency into the open delta side of the potential transformer (PT).This method is applicable to ungrounded systems; however, when measuring the grid-to-ground parameters of a system where the neutral point is grounded via an arc suppression coil, the arc suppression coil must be disconnected from operation beforehand. Its measurement principle is shown in Figure 1.As
Leon
07/25/2025
The insulation parameters of the power grid to ground are measured by the tuning method
The insulation parameters of the power grid to ground are measured by the tuning method
The tuning method is suitable for measuring the ground parameters of systems where the neutral point is grounded via an arc suppression coil, but not applicable to ungrounded neutral point systems. Its measurement principle involves injecting a current signal with continuously varying frequency from the secondary side of the Potential Transformer (PT), measuring the returned voltage signal, and identifying the system's resonant frequency.During the frequency sweeping process, each injected heter
Leon
07/25/2025
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
In an arc - suppression coil grounding system, the rising speed of the zero - sequence voltage is greatly affected by the value of the transition resistance at the grounding point. The larger the transition resistance at the grounding point, the slower the rising speed of the zero - sequence voltage.In an ungrounded system, the transition resistance at the grounding point has basically no impact on the rising speed of the zero - sequence voltage.Simulation Analysis: Arc - suppression Coil Ground
Leon
07/24/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!