What is the purpose of having separate earth, live, and neutral wires in an electrical circuit?

Encyclopedia
10/09/2024

The purpose of separating ground, live and neutral wires in a circuit

Fire line

Transmission of electrical energy: The fireline is the main line responsible for the transmission of electrical energy in the circuit. It transmits the alternating current provided by the power supply (such as 220V mains) to various electrical equipment to provide the energy required for the electrical equipment to work. For example, when you turn on a light bulb, the current flows from the live wire into the bulb, passes through the filament of the bulb, and then returns to the power supply through the neutral wire, thus making the bulb glow.

Provide high potential: Live wire has a high potential difference relative to neutral wire and ground wire. In AC circuits, the voltage of the fireline changes as a sine wave, and its peak is usually 2 times the root of 220V (about 311V). This high potential difference is the power source that drives the current to flow in the circuit, so that the electrical equipment can work properly. For example, in an electric motor, the current generated by the potential difference between the live and neutral wires causes the coils of the motor to generate a magnetic field, which drives the rotor of the motor to rotate.

Zero line

  • Form a loop: The main role of the neutral line is to form a circuit with the live line, so that the current can circulate between the power supply and the electrical equipment. Under normal circumstances, the potential of the zero line is close to the geodetic potential, and the potential of the ground line is very close. For example, in household electricity, the current flows from the live line into the electrical equipment, after the work of the electrical equipment, and then returns to the power supply through the neutral line, completing a complete circuit cycle.

  • Balance voltage: The neutral line also plays a role in balancing the voltage in the three-phase circuit. In the three-phase four-wire power supply system, the voltage phase difference of the three live lines is 120 degrees, and the voltage in the three-phase circuit can be balanced by connecting the neutral line. If the neutral line is disconnected or the contact is poor, it may lead to three-phase voltage imbalance, so that the electrical equipment can not work normally, and even damage the electrical equipment. For example, in some factories or commercial places, if the three-phase load is unbalanced, the current of the neutral line will increase, and it is necessary to ensure that the neutral line is well connected to ensure the stable operation of the power system.

Ground wire

  • Safety protection: The main purpose of the ground wire is to provide safety protection. When the electrical equipment has a fault such as leakage or short circuit, the ground wire can quickly introduce the leakage current into the earth to avoid human shock. For example, when the casing of a washing machine is charged, if the washing machine is connected to the ground wire, the leakage current will flow into the ground through the ground wire, rather than through the human body into the ground, thus protecting the safety of the user.

  • Eliminate static electricity: Ground wires can also eliminate static electricity generated by electrical equipment. In some dry environments, electrical equipment is prone to static electricity, if not eliminated in time, static electricity may accumulate to a higher potential, causing harm to the human body or equipment. By connecting the ground cable, the static electricity can be quickly released to the ground, ensuring the safety of the device and the environment. For example, in a computer room, in order to prevent electrostatic damage to electronic equipment, ground copper bars are usually laid to connect all electronic equipment to the ground wire to eliminate static electricity.

A single wire cannot serve all these purposes

Different electrical characteristics: The electrical characteristics of live wire, neutral wire and ground wire in the circuit are different. Firewire has a high potential difference and is responsible for transmitting electrical energy; The neutral line is used to form a loop and balance the voltage; Ground cables are used to protect and eliminate static electricity. If a wire is used to achieve these functions at the same time, it will cause the electrical performance of the circuit to be unstable, increasing the risk of electrical equipment failure. For example, if the ground and live or neutral wire are combined, when the electrical equipment leaks, the leakage current may not flow into the ground in time, thereby increasing the risk of human shock.

Safety standards are not allowed: In order to ensure electrical safety, countries have developed strict electrical safety standards, which clearly stipulates that the fire line, the neutral line and the ground line must be laid separately. These standards are based on long-term practical experience and scientific research to protect people's lives and property. If these standards are violated, using one wire instead of three wires can result in serious electrical accidents and even life-threatening conditions. For example, in the construction of electrical installation, if the construction personnel in order to save costs and the ground line and neutral line combined use, once the leakage accident occurs, the leakage protection device may not work properly, thus bringing great security risks to the user.



Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
Frequency division method for measuring grid-to-ground insulation parameters
Frequency division method for measuring grid-to-ground insulation parameters
The frequency division method enables the measurement of grid-to-ground parameters by injecting a current signal of a different frequency into the open delta side of the potential transformer (PT).This method is applicable to ungrounded systems; however, when measuring the grid-to-ground parameters of a system where the neutral point is grounded via an arc suppression coil, the arc suppression coil must be disconnected from operation beforehand. Its measurement principle is shown in Figure 1.As
Leon
07/25/2025
The insulation parameters of the power grid to ground are measured by the tuning method
The insulation parameters of the power grid to ground are measured by the tuning method
The tuning method is suitable for measuring the ground parameters of systems where the neutral point is grounded via an arc suppression coil, but not applicable to ungrounded neutral point systems. Its measurement principle involves injecting a current signal with continuously varying frequency from the secondary side of the Potential Transformer (PT), measuring the returned voltage signal, and identifying the system's resonant frequency.During the frequency sweeping process, each injected heter
Leon
07/25/2025
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
In an arc - suppression coil grounding system, the rising speed of the zero - sequence voltage is greatly affected by the value of the transition resistance at the grounding point. The larger the transition resistance at the grounding point, the slower the rising speed of the zero - sequence voltage.In an ungrounded system, the transition resistance at the grounding point has basically no impact on the rising speed of the zero - sequence voltage.Simulation Analysis: Arc - suppression Coil Ground