What is Incidence Matrix?

Electrical4u
03/13/2024

Incidence matrix is that matrix which represents the graph such that with the help of that matrix we can draw a graph. This matrix can be denoted as [AC] As in every matrix, there are also rows and columns in incidence matrix [AC].
The rows of the matrix [AC] represent the number of nodes and the column of the matrix [AC] represent the number of branches in the given graph. If there are ‘n’ number of rows in a given incidence matrix, that means in a graph there are ‘n’ number of nodes. Similarly, if there are ‘m’ number of columns in that given incidence matrix, that means in that graph there are ‘m’ number of branches.
incidence matrix

In the above shown graph or directed graph, there are 4 nodes and 6 branches. Thus the incidence matrix for the above graph will have 4 rows and 6 columns.
The entries of incidence matrix is always -1, 0, +1. This matrix is always analogous to
KCL (Krichoff Current Law). Thus from KCL we can derive that,

Type of branch Value
Outgoing branch from kth node +1
Incoming branch to kth node -1
Others 0

Steps to Construct Incidence Matrix

Following are the steps to draw the incidence matrix :-

  1. If a given kth node has outgoing branch, then we will write +1.

  2. If a given kth node has incoming branch, then we will write -1.

  3. Rest other branches will be considered 0.

Examples of Incidence Matrix

incidence matrix

For the graph shown above write its incidence matrix.
incidence matrix

Reduced Incidence Matrix

If from a given incidence matrix [AC], any arbitrary row is deleted, then the new matrix formed will be reduced incidence matrix. It is represented by symbol [A]. The order of reduced incidence matrix is (n-1) × b where n is the number of nodes and b is the number of branches.
For the above shown graph, the reduced incidence matrix will be :-
reduced incidence matrix
[NOTE :- In the above shown matrix row 4 is deleted.]
Now let us consider a new example related to reduced incidence matrix. For the graph shown above write its reduced incidence matrix.
directed graph
Answer:- In order to draw reduced incidence matrix first of all draw its incidence matrix. Its incidence matrix is :-

Now drawing its reduced incidence matrix. For this we just simply have to delete any node (in this we have deleted node 2). Its reduced incidence matrix is:-

This is the required answer.
Points to remember

  • For checking correctness of incidence matrix which we have drawn, we should check sum of column.

  • If sum of column comes to be zero, then the incidence matrix which we have created is correct else incorrect.

  • The incidence matrix can be applied only to directed graph only.

  • The number of entries in a row apart from zero tells us the number of branches linked to that node. This is also called as degree of that node.

  • The rank of complete incidence matrix is (n-1), where n is the number of nodes of the graph.

  • The order of incidence matrix is (n × b), where b is the number of branches of graph.

  • From a given reduced incidence matrix we can draw complete incidence matrix by simply adding either +1, 0, or -1 on the condition that sum of each column should be zero.

Source: Electrical4u.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Electrical4u

Electrical4U is dedicated to the teaching and sharing of all things related to electrical and electronics engineering.

Frequency division method for measuring grid-to-ground insulation parameters
Frequency division method for measuring grid-to-ground insulation parameters
The frequency division method enables the measurement of grid-to-ground parameters by injecting a current signal of a different frequency into the open delta side of the potential transformer (PT).This method is applicable to ungrounded systems; however, when measuring the grid-to-ground parameters of a system where the neutral point is grounded via an arc suppression coil, the arc suppression coil must be disconnected from operation beforehand. Its measurement principle is shown in Figure 1.As
Leon
07/25/2025
The insulation parameters of the power grid to ground are measured by the tuning method
The insulation parameters of the power grid to ground are measured by the tuning method
The tuning method is suitable for measuring the ground parameters of systems where the neutral point is grounded via an arc suppression coil, but not applicable to ungrounded neutral point systems. Its measurement principle involves injecting a current signal with continuously varying frequency from the secondary side of the Potential Transformer (PT), measuring the returned voltage signal, and identifying the system's resonant frequency.During the frequency sweeping process, each injected heter
Leon
07/25/2025
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
In an arc - suppression coil grounding system, the rising speed of the zero - sequence voltage is greatly affected by the value of the transition resistance at the grounding point. The larger the transition resistance at the grounding point, the slower the rising speed of the zero - sequence voltage.In an ungrounded system, the transition resistance at the grounding point has basically no impact on the rising speed of the zero - sequence voltage.Simulation Analysis: Arc - suppression Coil Ground
Leon
07/24/2025
Current Division and Voltage Division Rule
Current Division and Voltage Division Rule
Current Division RuleA parallel circuit functions as a current divider, where the incoming current splits among all branches while the voltage across each branch remains constant. The Current Division Rule is used to determine the current through circuit impedances, as illustrated by the circuit below:The currentI splits intoI1 andI2 across two parallel branches with resistancesR1 andR2, whereVdenotes the voltage drop across both resistances. As is known,Then the equation of the current is writt
Edwiin
06/02/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!