Negative Feedback in Op amp and Closed Loop Gain of Op amp

Electrical4u
03/13/2024

Negative Feedback in Op Amp

We obtain Negative feedback in an op amp by connecting output terminal of an op amp to its inverting input terminal through a suitable resistance as shown below.

Negative Feedback in Op Amp

The gain of an op amp with negative feedback is called closed loop gain.

Closed Loop Gain of Op Amp

When we connect a feedback resistance and a resistance in series with the inverting input terminal of an op-amp as shown in the above picture, the gain of the system just becomes the negative ratio of feedback resistance to input resistance. The operational amplifier has its own gain. The gain is practically very large and ideally, it is infinity. We can impose a predetermined gain to the system irrespective of op amp’s own gain (open loop gain). We do this by choosing the appropriate values of series input resistance (Ri) and feedback resistance (Rf). The gain of the op-amp system should be

To understand the closed loop gain of an 741 op amp, let us go through an example. 741 operational amplifier has following perameters.

Parameter

Value

Open Loop Gain

2 × 105

Input Resistance

2 MΩ

Output Resistance

5 Ω

Let us find the closed loop gain of the op amp when we connect a 10 kΩ resistance in series with the inverting terminal and a 20kΩ resistance as feedback path.

closed loop gain

The equivalent circuit of the op amp with input source will be as shown below,

equivalent circuit

Let us assume, the voltage at node 1 is v. Now applying Kirchhoff current law at this node. we get,


Now by applying Kirchhoff current law at node 2 get,



Now, from the figure it is found that,


From equation (i) and (ii) we get,


So, the open loop gain of the op amp is, 2 × 105.
whereas closed loop gain comes to only 2.

Let us take another example of closed loop gain of an op amp.


The equivalent circuit of above 741 op amp circuit can be redrawn as,

741 opamp circuit

Now, consider voltage at node 1 is v applying Kirchhoffs current law at node 1. We get,


Now, applying Kirchhoffs current law at node of the equivalent circuit, We get,


Now,



From the equation (iii) and (iv), we get,


So, the closed loop gain of the above op amp circuit is 8.
So, it is cleared that by choosing suitable
resistor for feedback in an op amp circuit, we can impose its desired gain.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Electrical4u

Electrical4U is dedicated to the teaching and sharing of all things related to electrical and electronics engineering.

Frequency division method for measuring grid-to-ground insulation parameters
Frequency division method for measuring grid-to-ground insulation parameters
The frequency division method enables the measurement of grid-to-ground parameters by injecting a current signal of a different frequency into the open delta side of the potential transformer (PT).This method is applicable to ungrounded systems; however, when measuring the grid-to-ground parameters of a system where the neutral point is grounded via an arc suppression coil, the arc suppression coil must be disconnected from operation beforehand. Its measurement principle is shown in Figure 1.As
Leon
07/25/2025
The insulation parameters of the power grid to ground are measured by the tuning method
The insulation parameters of the power grid to ground are measured by the tuning method
The tuning method is suitable for measuring the ground parameters of systems where the neutral point is grounded via an arc suppression coil, but not applicable to ungrounded neutral point systems. Its measurement principle involves injecting a current signal with continuously varying frequency from the secondary side of the Potential Transformer (PT), measuring the returned voltage signal, and identifying the system's resonant frequency.During the frequency sweeping process, each injected heter
Leon
07/25/2025
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
In an arc - suppression coil grounding system, the rising speed of the zero - sequence voltage is greatly affected by the value of the transition resistance at the grounding point. The larger the transition resistance at the grounding point, the slower the rising speed of the zero - sequence voltage.In an ungrounded system, the transition resistance at the grounding point has basically no impact on the rising speed of the zero - sequence voltage.Simulation Analysis: Arc - suppression Coil Ground
Leon
07/24/2025
Current Division and Voltage Division Rule
Current Division and Voltage Division Rule
Current Division RuleA parallel circuit functions as a current divider, where the incoming current splits among all branches while the voltage across each branch remains constant. The Current Division Rule is used to determine the current through circuit impedances, as illustrated by the circuit below:The currentI splits intoI1 andI2 across two parallel branches with resistancesR1 andR2, whereVdenotes the voltage drop across both resistances. As is known,Then the equation of the current is writt
Edwiin
06/02/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!