RL Circuit Transfer Function Time Constant RL Circuit as Filter

Electrical4u
03/13/2024

The resistor and inductor are the most fundamental linear (element having linear relationship between voltage and current) and passive (which consume energy) elements. When resistor and inductor are connected across voltage supply, the circuit so obtained is called RL circuit.
rl seriesl circuit

Types of RL Circuit

  1. RL Series Circuit- When resistance and inductor are connected in series with voltage supply. The circuit is called series RL circuit.

  2. RL Parallel Circuit- When resistance and inductor are connected in parallel with each other and is driven by voltage source, the circuit so obtained is called parallel RL circuit.

rl parallel circuit

Transfer Function of Series RL Circuit

A transfer function is used to analysis RL circuit. It is defined as the ratio of the output of a system to the input of a system, in the Laplace domain.
rl circuit

Consider a RL circuit in which resistor and inductor are connected in series with each other.
Let Vin be the input supply voltage,
VL is the voltage across inductor, L,
VR is the voltage across resistor,
and I is the current flowing through the circuit.

Now for finding transfer function apply voltage or potential divider rule. The voltage divider rule is a simplest rule used for determine the output voltage across any element in circuit.
It states that the voltage divided between the resistors is in direct proportion to their respective
resistance.
Using voltage divider rule, the voltage across inductor VL is:

The voltage across the resistor VR is:

The transfer function, HL for the inductor is:

Similarly, the transfer function, HR for the resistor is,

Current
Since the circuit is in series so the current in resistor and inductor are the same and is given by:

Time Constant in RL Circuit

rl circuit
The time constant of an RL circuit is defined as the time taken by the current to reach its maximum value that had maintained during its initial rate of rise.
The time constant of a series RL circuit equal to the ratio of value of inductor to the value of resistance:
Where,
T = time constant in seconds,
L = inductor in Henry,
R = resistance in ohms.
time costant of rl circuit
In RL circuit due to presence of inductor the current in the circuit does not build up at a steady rate because inductor has a property to oppose the change in current flowing through it. So rate of increase in current is initially rapid but it slows down as it approaches its maximum value. During each time constant, the current build up 63.2 % of its remaining distance. As shown in graph it takes 5 times constant to build up a current in RL circuit.

RL Circuit as Filter

Low Pass RL Filter

Consider a RL circuit is supplying with a voltage source of varying frequency and the circuit output voltage is taken across resistor R1. The resistor R1 is independent of frequency but the inductive reactance is directly proportional to frequency (as XL = 2πfL). At low or zero (as in case of DC) frequency, the inductive reactance XL is very small as compared to resistance because when frequency is low, inductive reactance is also low so, it act as a short circuit. As there is no voltage drop across inductor the output voltage is almost same as that of input voltage both in magnitude and the phase and it acts as low pass filter. Now when frequency is increases, inductive reactance, XL also increases and this causes increase in magnitude of voltage drop across inductor and hence reduce the output voltage across resistor. This increase in inductive reactance creates a phase shift between input and output voltage.
rl circuit

High Pass RL Filter

Consider a RL circuit is supplying with a voltage source of varying frequency and the circuit output voltage is taken across inductor, L1. At very low or zero frequency, inductive impedance is zero so, inductor acts as short circuit and the output voltage across it is zero. As the frequency increases, inductive reactance also increases causing more voltage to drop across it and it act as high pass filter.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Electrical4u

Electrical4U is dedicated to the teaching and sharing of all things related to electrical and electronics engineering.

Frequency division method for measuring grid-to-ground insulation parameters
Frequency division method for measuring grid-to-ground insulation parameters
The frequency division method enables the measurement of grid-to-ground parameters by injecting a current signal of a different frequency into the open delta side of the potential transformer (PT).This method is applicable to ungrounded systems; however, when measuring the grid-to-ground parameters of a system where the neutral point is grounded via an arc suppression coil, the arc suppression coil must be disconnected from operation beforehand. Its measurement principle is shown in Figure 1.As
Leon
07/25/2025
The insulation parameters of the power grid to ground are measured by the tuning method
The insulation parameters of the power grid to ground are measured by the tuning method
The tuning method is suitable for measuring the ground parameters of systems where the neutral point is grounded via an arc suppression coil, but not applicable to ungrounded neutral point systems. Its measurement principle involves injecting a current signal with continuously varying frequency from the secondary side of the Potential Transformer (PT), measuring the returned voltage signal, and identifying the system's resonant frequency.During the frequency sweeping process, each injected heter
Leon
07/25/2025
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
In an arc - suppression coil grounding system, the rising speed of the zero - sequence voltage is greatly affected by the value of the transition resistance at the grounding point. The larger the transition resistance at the grounding point, the slower the rising speed of the zero - sequence voltage.In an ungrounded system, the transition resistance at the grounding point has basically no impact on the rising speed of the zero - sequence voltage.Simulation Analysis: Arc - suppression Coil Ground
Leon
07/24/2025
Current Division and Voltage Division Rule
Current Division and Voltage Division Rule
Current Division RuleA parallel circuit functions as a current divider, where the incoming current splits among all branches while the voltage across each branch remains constant. The Current Division Rule is used to determine the current through circuit impedances, as illustrated by the circuit below:The currentI splits intoI1 andI2 across two parallel branches with resistancesR1 andR2, whereVdenotes the voltage drop across both resistances. As is known,Then the equation of the current is writt