How To Find The Time Constant in RC and RL Circuits

Electrical4u
03/13/2024

What is the Time Constant?

The time constant – usually denoted by the Greek letter τ (tau) – is used in physics and engineering to characterize the response to a step input of a first-order, linear time-invariant (LTI) control system. The time constant is the main characteristic unit of a first-order LTI system.

The time constant is commonly used to characterize the response of an RLC circuit.

To do this, let us derive the time constant for an RC circuit, and the time constant for an RL circuit.

Time Constant of an RC Circuit

Let us take a simple RC circuit, as shown below.

RC circuit

Let us assume the capacitor is initially uncharged and the switch S is closed at time t = 0. After closing the switch, electric current i(t) starts flowing through the circuit. Applying Kirchhoff Voltage Law in that single mesh circuit, we get,

Differentiating both sides with respect to time t, we get,


Integrating both sides we get,

Now, at t = 0, the capacitor behaves as a short circuit, so, just after closing the switch, the current through the circuit will be,


Now, putting this value in equation (I), we get,


Putting the value of k at equation (I), we get,


Now, if we put t = RC in the final expression of circuit current i(t), we get,


From the above mathematical expression, it is clear that RC is the time in second during which the current in a charging capacitor diminishes to 36.7 percent from its initial value. Initial value means current at the time of switching on the unchanged capacitor.

This term is quite significant in analyzing the behavior of capacitive as well as inductive circuits. This term is known as the time constant.

So time constant is the duration in seconds during which the current through a capacities circuit becomes 36.7 percent of its initial value. This is numerically equal to the product of resistance and capacitance value of the circuit. The time constant is normally denoted by τ (tau). So,


In a complex RC circuit, the time constant will be the equivalent resistance and capacitance of the circuit.

Let us discuss the significance of the time constant in more detail. To do this, let us first plot current i(t).

charging current plot

At t = 0, the current through the capacitor circuit is


At t = RC, the current through the capacitor is


Let us consider another RC circuit.

RC circuit

Circuit equations using KVL of the above circuits are,


and



From (iii) and (v)


Differentiating both sides with respect to time t, we get,



Integrating both sides we get,


At t = 0,


The time constant of this circuit would be 2RC/3 sec. Now, the equivalent resistance of the circuit is,



The time constant of the circuit has become.


Time Constant of an RL Circuit

Let us consider an example of a series RL circuit.

RL circuit

Applying Kirchhoff Voltage Law in the above circuit. We get,


The equation can also be solved Laplace Transformation technique. For that, we have to take Laplace Transformation of the equation at both sides,



Hence, in this equation.


Since the current just after the switch is on, the current through the inductor will be zero.
Now,


Taking inverse Laplace of the above equation, we get,


Now, if we put,


We get,


At the RL circuit, at time = L/R sec, the current becomes 63.3% of its final steady-state value. The L/R is known as the time constant of an LR circuit. Let us plot the current of the inductor circuit.

current of inductor circuit

The time constant of an LR circuit is the ratio of inductance to the resistance of the circuit. Let us take another.


This circuit can be redrawn as,


So, the time constant of the circuit would be

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Electrical4u

Electrical4U is dedicated to the teaching and sharing of all things related to electrical and electronics engineering.

Frequency division method for measuring grid-to-ground insulation parameters
Frequency division method for measuring grid-to-ground insulation parameters
The frequency division method enables the measurement of grid-to-ground parameters by injecting a current signal of a different frequency into the open delta side of the potential transformer (PT).This method is applicable to ungrounded systems; however, when measuring the grid-to-ground parameters of a system where the neutral point is grounded via an arc suppression coil, the arc suppression coil must be disconnected from operation beforehand. Its measurement principle is shown in Figure 1.As
Leon
07/25/2025
The insulation parameters of the power grid to ground are measured by the tuning method
The insulation parameters of the power grid to ground are measured by the tuning method
The tuning method is suitable for measuring the ground parameters of systems where the neutral point is grounded via an arc suppression coil, but not applicable to ungrounded neutral point systems. Its measurement principle involves injecting a current signal with continuously varying frequency from the secondary side of the Potential Transformer (PT), measuring the returned voltage signal, and identifying the system's resonant frequency.During the frequency sweeping process, each injected heter
Leon
07/25/2025
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
In an arc - suppression coil grounding system, the rising speed of the zero - sequence voltage is greatly affected by the value of the transition resistance at the grounding point. The larger the transition resistance at the grounding point, the slower the rising speed of the zero - sequence voltage.In an ungrounded system, the transition resistance at the grounding point has basically no impact on the rising speed of the zero - sequence voltage.Simulation Analysis: Arc - suppression Coil Ground
Leon
07/24/2025
Current Division and Voltage Division Rule
Current Division and Voltage Division Rule
Current Division RuleA parallel circuit functions as a current divider, where the incoming current splits among all branches while the voltage across each branch remains constant. The Current Division Rule is used to determine the current through circuit impedances, as illustrated by the circuit below:The currentI splits intoI1 andI2 across two parallel branches with resistancesR1 andR2, whereVdenotes the voltage drop across both resistances. As is known,Then the equation of the current is writt
Edwiin
06/02/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!