Types of Controllers

Encyclopedia
Field: Encyclopedia
0
China

Controller Definition


In control systems, a controller is a mechanism that seeks to minimize the difference between the actual value of a system (i.e. the process variable) and the desired value of the system (i.e. the setpoint). Controllers are a fundamental part of control engineering and used in all complex control systems.


Before we introduce you to various controllers in detail, it is essential to know the uses of controllers in the theory of control systems. The important uses of the controllers include:


  • Controllers improve the steady-state accuracy by decreasing the steady state error.



  • As the steady-state accuracy improves, the stability also improves.



  • Controllers also help in reducing the unwanted offsets produced by the system.



  • Controllers can control the maximum overshoot of the system.



  • Controllers can help in reducing the noise signals produced by the system.


  • Controllers can help to speed up the slow response of an overdamped system.


Types of Controllers


There are two main types of controllers: continuous controllers, and discontinuous controllers.


In discontinuous controllers, the manipulated variable changes between discrete values. Depending on how many different states the manipulated variable can assume, a distinction is made between two position, three position, and multi-position controllers.


Compared to continuous controllers, discontinuous controllers operate on very simple, switching final controlling elements.


The main feature of continuous controllers is that the controlled variable (also known as the manipulated variable) can have any value within the controller’s output range.


Now in the continuous controller theory, there are three basic modes on which the whole control action takes place, which are:


  • Proportional controllers.

  • Integral controllers.

  • Derivative controllers.


We use the combination of these modes to control our system such that the process variable is equal to the setpoint (or as close as we can get it). These three types of controllers can be combined into new controllers:


  • Proportional and integral controllers (PI Controller)

  • Proportional and derivative controllers (PD Controller)

  • Proportional integral derivative control (PID Controller)

Give a tip and encourage the author!

Recommended

Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Reclosing Charge Time: Why Does Reclosing Require Charging? What Effects Does Charging Time Have?
1. Function and Significance of Reclosing ChargingReclosing is a protective measure in power systems. After faults such as short circuits or circuit overloads occur, the system isolates the faulty circuit and then restores normal operation through reclosing. The function of reclosing is to ensure continuous operation of the power system, improving its reliability and safety.Before performing reclosing, the circuit breaker must be charged. For high-voltage circuit breakers, the charging time is g
12/15/2025
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.