What is a Transmission Tower?

Encyclopedia
Field: Encyclopedia
0
China

What is a  Transmission Tower?

Transmission Tower Definition

A transmission tower is defined as a tall structure used to support overhead power lines, transporting high-voltage electricity from generating stations to substations.

Transmission Tower Parts

A power transmission tower is essential for power transmission systems and consists of several parts:

  • The peak of the transmission tower

  • The cross arm of the transmission tower

  • The boom of transmission tower

  • Cage of transmission tower

  • Transmission Tower Body

  • Leg of transmission tower

  • Stub/Anchor Bolt and Baseplate assembly of the transmission tower.

These parts have been described below. Note that the construction of these towers is not a simple task, and there is a tower erection methodology behind building these high voltage transmission towers.

Design Importance

Transmission towers must support heavy conductors and withstand natural disasters, requiring robust engineering in civil, mechanical, and electrical fields.

Parts of a Transmission Tower

Key parts include the peak, cross arm, boom, cage, body, legs, and baseplate assembly, each playing a crucial role in the tower’s function.

Cross Arm of Transmission Tower

The cross arms hold the transmission conductors. Their size depends on the transmission voltage, configuration, and stress distribution angle.

Cage of Transmission Tower

The portion between tower body and peak is known as cage of transmission tower. This portion of the tower holds the cross arms.

Transmission Tower Body

1140458a04e55ca18ddd571660e316fc.jpeg

 The tower body extends from the bottom cross arms to the ground and is vital for maintaining the ground clearance of the bottom conductor of the transmission line.

d6bde8c725db5d69109a10156444c9d4.jpeg

 Transmission Tower Design

8077e8d832645f7cdfa3e72dd466e4eb.jpeg

 During design of transmission tower the following points to be considered in mind

  • The minimum ground clearance of the lowest conductor point above the ground level.

  • The length of the insulator string.

  • The minimum clearance to be maintained between conductors and between conductor and tower.

  • The location of a ground wire with respect to outermost conductors.

  • The midspan clearance required from considerations of the dynamic behavior of the conductor and lightning protection of the power line.

 To determine the actual transmission tower height by considering the above points, we have divided the total height of the tower into four parts:

  • Minimum permissible ground clearance (H1)

  • Maximum sag of the overhead conductor (H2)

  • Vertical spacing between the top and bottom conductors (H3)

  • Vertical clearance between the ground wire and top conductor (H4)

 Higher voltage transmission lines require greater ground clearance and vertical spacing. Therefore, high-voltage towers have higher ground clearance and larger spacing between conductors.

Types of Electrical Transmission Towers

According to different considerations, there are different types of transmission towers.

The transmission line goes as per available corridors. Due to the unavailability of the shortest distance straight corridor transmission line has to deviate from its straightway when obstruction comes. In the total length of a long transmission line, there may be several deviation points. According to the angle of deviation, there are four types of transmission tower

  • A – type tower – angle of deviation 0o to 2o.

  • B – type tower – angle of deviation 2o to 15o.

  • C – type tower – angle of deviation 15o to 30o.

  • D – type tower – angle of deviation 30o to 60o.

As per the force applied by the conductor on the cross arms, the transmission towers can be categorized in another way

Tangent suspension tower and it is generally A – type tower.

Angle tower or tension tower or sometime it is called section tower. All B, C and D types of transmission towers come under this category.

Apart from the above-customized type of tower, the tower is designed to meet special usages listed below:

These are called special type tower

  • River crossing tower

  • Railway/ Highway crossing tower

  • Transposition tower

Based on numbers of circuits carried by a transmission tower, it can be classisfied as

  • Single circuit tower

  • Double circuit tower

  • Multi circuit tower.

Transmission Tower Design

Design considerations include ground clearance, conductor spacing, insulator length, ground wire location, and midspan clearance, which are vital for safe and efficient operation.

0cdeb7b5f60c95fd20837b16203ebc09.jpeg

Give a tip and encourage the author!

Recommended

Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
01/30/2026
Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.