Failure Analysis of Electric Vehicle AC Charging Piles

Felix Spark
06/23/2025

As new energy electric vehicles become increasingly popular, the number of supporting public charging piles is growing year by year. Whether the measurement value of AC charging piles for electric vehicles is accurate is directly related to the vital interests of the vast number of electric vehicle owners. So, conducting regular mandatory inspections of charging piles is particularly important. Below, combined with relevant regulations and practical work, I’ll share some experience and practices on properly carrying out verification, fault analysis, repair, and correct maintenance of AC charging piles for electric vehicles.
1 Common Faults of AC Charging Piles for Electric Vehicles
During the use of AC charging piles, the main circuit is directly affected by current and voltage stress, which is the main cause of faults in AC charging piles. In terms of fault states, there are mainly two common situations for charging piles.
1.1 The power indicator of the charging pile is not on and it can’t charge
1.1.1 Fault Causes
A possible fault cause is that the charging power connection is abnormal:

The AC charging connection device is not properly connected; there is a fault in the charging pile circuit.

1.1.2 Fault Diagnosis & Troubleshooting
Diagnosis flow as Figure 1.
  • Check distribution cabinet main switch (closed in normal operation; close if open).
  • Test main switch output voltage (L - N, L - PE should be 220V). Abnormal voltage → check/reconnect circuit or replace switch (open, loose, damaged).
  • Test charging pile input voltage (L - N, L - PE should be 220V). Abnormal voltage → reconnect circuit or replace switch (open/damaged).
1.2 Physical Connection Done, Charging Started but No Charge
Occurs when power, plug - battery connection, and standby state are normal. 7 cases:
  • Normal charge but monitoring data shows 0 → Communication fault between pile & system.
    Fix: ① Restart monitoring/server; ② Reboot pile display; ③ Power - cycle display system & program.
  • Charge current <20A (normal state) → Display/program fault.
    Fix: ① Restart display program; ② Power - cycle pile & program; ③ Reinstall display/program.
  • Can’t charge/enter interface → Communication fault.
    Fix: ① Check display parameters; ② Power - cycle display system/program; ③ Reinstall display/program.
  • No BMS communication after display reboot → Communication fault.
    Fix: ① Power - cycle display system/program; ② Reinstall display/program; ③ Replace CAN bus module 200T.
  • BMS normal, voltage normal but 0 current → Mistaken emergency stop press.
    Fix: ① Release emergency stop; ② Check battery & BMS.
  • BMS normal, no charge voltage → Mistaken emergency stop press.
    Fix: ① Release emergency stop; ② Check battery & BMS.
  • BMS normal, voltage fluctuates, 0 current → Charging module fault.
    Fix: Replace module.

2 Proper Use & Maintenance of EV Charging Piles

  • Pre - charge: Inspect equipment (cables, connectors) for damage.
  • Abnormality during use: Press emergency stop → cut all power.
  • Keep flammables/explosives (gases, chemicals) away.
  • Don’t use if gun/cable has defects (cracks, wear, exposed wires).
  • Never unplug during charging; no live - contact with gun core.
  • Avoid outdoor charging in rain/thunder. Prohibit charging if water nears vehicle height.
Felix Spark

Hey there! I'm an electrical engineer specializing in Failure and Maintenance. I've dedicated my career to ensuring the seamless operation of electrical systems. I excel at diagnosing complex electrical failures, from malfunctioning industrial motors to glitchy power distribution networks. Using state - of - the - art diagnostic tools and my in - depth knowledge, I pinpoint issues quickly. On this platform, I'm eager to share my insights, exchange ideas, and collaborate with fellow experts. Let's work together to enhance the reliability of electrical setups.

Vibration Testing and Fault Research of High - Voltage Shunt Reactors
Vibration Testing and Fault Research of High - Voltage Shunt Reactors
1 Vibration Monitoring and Fault Diagnosis Technology for High - Voltage Shunt Reactors1.1 Measuring Point Layout StrategyVibration characteristic parameters (frequency, power, energy) of high - voltage shunt reactors are fully recorded in operation logs. For vibration analysis, focus on resolving the complexity of electric field distribution at winding ends. Quantitatively evaluate field - strength distribution under operating/lightning overvoltage and voltage gradient characteristics of longit
Felix Spark
07/24/2025
Research on Online Diagnosis of Secondary Circuit Faults of Electronic Current Transformers
Research on Online Diagnosis of Secondary Circuit Faults of Electronic Current Transformers
1 Principle and Role of Electronic Current Transformers1.1 Working Principle of ECTAn Electronic Current Transformer (ECT) is a key device for managing safe power system operations, converting large currents into manageable small-current signals for measurement and control. Unlike traditional transformers (relying on direct magnetic field interaction between primary and secondary windings), ECTs use sensors (e.g., Hall effect sensors) to detect magnetic field changes from the primary winding. Th
Felix Spark
07/22/2025
What are the fault diagnosis and handling technologies for 35kV combined transformers?
What are the fault diagnosis and handling technologies for 35kV combined transformers?
For fault diagnosis and handling of 35kV combined transformers, the following technical means can be adopted:Insulation Fault DiagnosisUse equipment such as high-voltage test transformers, power frequency withstand voltage testers, and partial discharge detection systems to conduct a comprehensive assessment of the insulation performance of combined transformers. When the insulation resistance is found to be lower than 1000MΩ or the dielectric loss factor tanδ exceeds 0.5%, an applic
Felix Spark
07/21/2025
What are the common faults of low-voltage voltage transformers?
What are the common faults of low-voltage voltage transformers?
Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In low
Felix Spark
07/18/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!