Construction of a DC Generator

Encyclopedia
08/19/2024

Dc generator definition


A DC generator is defined as an electrical device that converts mechanical energy into direct current (DC) electricity. It works according to the principle of electromagnetic induction, when a conductor passes through a magnetic field, it creates a potential difference in the conductor, which, if connected to a closed circuit, causes a current to flow.


Structure of DC generator


Yoke


The yoke is usually made of cast iron or cast steel, depending on the size and weight of the generator.


Yoke use


It holds the magnetic poles of the generator in place and acts as a protective cover for the machine.

It carries the magnetic flux produced by the field winding.


Magnetic poles and field windings


The magnetic poles and field windings are the stationary components of a DC generator that generate the main magnetic field in the machine. They are bolted to the inside and outside of the yoke.


The vertical rod is made of laminated steel or solid cast iron or steel. Lamination reduces eddy current losses in the magnetic poles. The poles are protruding, which means they protrude inward from the yoke.



Armature


The armature is defined as the rotating part of a DC generator that carries the armature winding in which the electromotive force is induced by the magnetic field. It is mounted on a shaft that rotates between the poles.


The armature core is made of laminated steel with grooves on its outer surface. These slots are used to hold the armature conductors insulated from each other and from the core. Lamination reduces eddy current losses in the core.


Armature winding is formed by connecting several coils of insulated copper wire or tape in a specific pattern. There are two types of armature winding: lap winding and waveform winding.


Lap winding: In this type of winding, each coil end is connected to an adjacent commutator segment and another coil end on the same side of the armature.


Waveform winding: In this type of winding, each coil end is connected to a commutator segment that is one pole distance away from the commutator segment and connected to another coil end on the other side of the armature.


Commutator


A commutator is a mechanical device that converts the AC electromotive force induced in the armature winding into the DC voltage at both ends of the load terminal. It acts as a rectifier for DC power generation.


The commutator consists of wedge-shaped segments of hard-drawn or fall-wrought copper that are insulated from each other and from the shaft by mica sheets. Each segment is connected to the armature conductor via a riser or connector.


The commutator segments are arranged in a cylindrical shape on the axis and rotate with the axis. The number of segments depends on the number of coils in the armature winding.


Electric brush


Brushes are made of carbon or graphite blocks that collect current from the commutator segment and transmit it to an external circuit. They also provide electrical contact between the stationary and rotating parts of the generator.


Brushes are housed in rectangular boxes called brush brackets, which are attached to a yoke or bearing bracket. The brush holder has a spring that allows the brush to be pressed against the commutator with appropriate pressure. The brush should be placed on the commutator where the induced electromotive force in the armature conductor changes its direction. These locations are called neutral zones or geometric neutral axes (GNA).


Bearing


Bearings are used to support the rotating shaft of the generator and reduce friction between the shaft and the stationary components. They also allow the shaft to rotate smoothly and evenly.


For small generators, ball bearings are used because they have low friction and high efficiency. For large generators, roller bearings are used because they can withstand heavy loads and shocks.


Bearings must be properly lubricated to ensure smooth operation and long service life of the generator. Lubrication can be done through oil rings, oil baths, grease cups or forced lubrication systems.



Working principle


When the armature rotates in a magnetic field, it induces an electromotive force in the conductor according to Faraday's law of electromagnetic induction.


Type of DC generator


Individually excited DC generator: In this type, the excitation coil is excited by an independent external DC power source, such as a battery or other DC generator.

Self-excited DC generator: In this type, the excitation coil is excited by its own generated voltage after initial magnetization through residual magnetism. There are three subtypes: series winding, split winding and compound winding.

Permanent magnet DC generator: In this type, there is no magnetic field coil, but a permanent magnet that provides a constant magnetic flux.



Apply


  • Charge batteries for cars, inverters and solar panels.


  • Power traction motors for electric cars, trains and cranes.


  • Power supply for arc welding machine, electroplating equipment and electrolytic process.


  • Provide power to remote areas where AC transmission is not feasible or economical.


  • Supply power to test AC machines and circuits.


Conclusion


Dc generator is an important device for converting mechanical energy into electric energy by electromagnetic induction. It has several components, such as a yoke, pole, field winding, armature, commutator, brush and bearing, which work together to produce direct current. Dc generators can be divided into different types according to their excitation method. Dc generators have a variety of applications in different fields such as battery charging, traction, welding, electroplating, electrolysis and remote power supply.


Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!