What is the reason for the rotor of an induction motor having a different number of poles than the stator?

Encyclopedia
10/05/2024

The number of rotor poles in Induction motors is usually the same as the number of stator poles, because the working principle of the Motor depends on the rotating magnetic field generated by the interaction between the stator and the rotor. The following explains in detail why the number of rotor poles is usually the same as the number of stator poles, and explores whether reversing the number of poles can improve the performance of the motor.


Why is the number of rotor poles the same as the number of stator poles?


Synchronous magnetic field


  • Stator winding: The rotating magnetic field generated by the stator winding is a fixed number of poles, usually an even number of pole pairs (such as 2-pole pairs, 4-pole equivalents).


  • Rotor winding: In order for the rotor to be able to rotate with the stator magnetic field, the rotor must also have the same number of poles so that it can synchronize with the stator magnetic field to produce a constant electromagnetic torque.



Torque generation


  • Induced current: When the stator generates a rotating magnetic field, a current is induced in the rotor, and the magnetic field formed by these currents in the rotor interacts with the stator magnetic field to produce torque.


  • Pole matching: Only when the number of rotor poles is the same as the number of stator poles can the rotor magnetic field be synchronized with the stator magnetic field, thereby effectively generating torque.



Slip rate


  • Synchronous speed: The synchronous speed ns of the motor is proportional to the pole number p and the power supply frequency f, that is, ns= 120f/ p


  • Actual speed: the actual speed n of the rotor is always less than the synchronous speed, and the ratio of the difference to the synchronous speed is called the slip rate s.That is s= (ns−n)/ns.



Does reversing poles improve performance?


The effect of polar inversion


  • Magnetic field asymmetry: If the number of rotor poles does not match the number of stator poles, it will lead to magnetic field asymmetry, which will affect the normal operation of the motor.


  • Torque fluctuation: Pole mismatch will cause torque fluctuation to increase, the motor operation is unstable, and even can not start or run normally.



Performance impact


  • Reduced efficiency: Pole mismatches can lead to reduced motor efficiency because of reduced energy conversion efficiency.


  • Noise and vibration: Asymmetrical magnetic fields can cause the motor to produce additional noise and vibration, affecting the service life of the equipment.



Other considerations


  • Design flexibility: In some special designs, such as two-speed motors, the number of poles can be changed by changing the connection of the stator windings to achieve different speeds. But this is still pre-set at design time, rather than randomly changing the number of poles.


  • Types of motors: Different types of motors (such as permanent magnet synchronous motors) may have different combinations of poles, but these are designed for specific application purposes.



Sum up


The number of rotor poles in an induction motor is usually the same as the number of stator poles, which is to ensure that the rotor can rotate synchronously with the stator magnetic field, resulting in a stable electromagnetic torque. If the number of poles is reversed (that is, the number of poles is changed), the magnetic field will be asymmetrical, the torque fluctuation will be increased, the motor efficiency will be reduced, and additional noise and vibration will be generated. Therefore, reversing the number of poles will not improve the performance of the motor, but will make the motor not work properly. In practical applications, any modification of the motor pole number should be carried out under the guidance of professionals and ensure that it meets the design requirements of the motor.


Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!