Can you explain what DC excitation is and why it is primarily used in small generators?

Encyclopedia
10/17/2024

DC excitation refers to an excitation method that uses direct current to generate a magnetic field in a generator.

I. Working principle of DC excitation

In a DC excitation system, there is usually a DC power source (such as a battery or rectifier), and the DC current is introduced into the excitation winding of the generator through devices such as slip rings and brushes. The DC current flowing through the excitation winding generates a constant magnetic field, and this magnetic field rotates together with the rotor of the generator. When the rotor of the generator is driven by a prime mover (such as a steam turbine or water turbine) to rotate, an alternating electromotive force will be induced in the stator winding.

For example, in a small DC excitation generator, the current provided by the DC power source enters the excitation winding through slip rings and brushes. The generated magnetic field causes an alternating voltage to be generated in the stator winding when the rotor rotates. This alternating voltage can be stepped up by a transformer and transmitted to the power grid or directly supplied to loads for use.

II. Reasons why DC excitation is mainly used in small generators

Simple and reliable

The DC excitation system is relatively simple and consists of a DC power source, slip rings, brushes, and excitation windings. Its simple structure makes the system highly reliable and less prone to failures. For small generators, a simple and reliable excitation system is easier to maintain and manage.

For example, in some small hydropower stations or wind power generation systems, small generators with DC excitation can operate stably in relatively harsh environments because the failure probability of their excitation systems is low.

Low cost

The power of small generators is usually small, and the required excitation current is also relatively small. Therefore, the DC power source and other equipment required by the DC excitation system can be selected in smaller specifications, thereby reducing costs.

In contrast, large generators usually use AC excitation or other more complex excitation methods. These systems require more powerful excitation equipment and have higher costs.

Easy to control

The excitation current of the DC excitation system can be controlled by adjusting the output voltage or current of the DC power source. This control method is relatively simple and can easily realize the adjustment of the output voltage and power of the generator.

For small generators, it is usually necessary to adjust the output voltage and power in time according to the change of load. The easy-to-control characteristic of the DC excitation system makes it more suitable for the application of small generators.

Strong adaptability

Small generators are usually used in some special occasions, such as independent power supply systems in remote areas and emergency power supplies. These occasions may have higher requirements for the starting performance and load change adaptability of generators. The DC excitation system can provide a large excitation current when the generator starts, enabling the generator to quickly establish voltage; at the same time, when the load changes, it can also quickly adjust the excitation current to maintain the stability of the generator output voltage.

For example, in some remote areas without grid connection, small generators with DC excitation can provide reliable power supply for local residents. Even when the load changes greatly, the voltage can be stabilized.

In conclusion, DC excitation is mainly used in small generators because it has the advantages of simplicity, reliability, low cost, easy control, and strong adaptability.


Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!