How do I calculate a number of turn per slot in a single phase or three phase induction motor?

Encyclopedia
10/19/2024

Calculating the number of turns per slot in a single-phase or three-phase induction motor (also known as an asynchronous motor) involves details of the motor's design and specific parameters. The design of the motor's windings aims to optimize the motor's performance, including efficiency, power factor, and reliability. Below are the general steps and methods to calculate the number of turns per slot:

Overview of Steps

  1. Determine Motor Parameters: Understand the basic parameters of the motor, including rated power, rated voltage, frequency, number of poles, and number of slots.

  2. Calculate Total Turns: Based on the design requirements of the motor, calculate the total number of turns in the windings.

  3. Allocate Turns Per Slot: Distribute the total number of turns among each slot.

Specific Steps

1. Collect Motor Parameters

  • Rated Power (P): The rated output power of the motor.

  • Rated Voltage (U): The operating voltage of the motor.

  • Frequency (f): The power supply frequency, typically 50Hz or 60Hz.

  • Number of Pole Pairs (p): The number of pole pairs, which determines the synchronous speed of the motor.

  • Number of Slots (Z): The number of slots on the stator.

  • Number of Phases (m): Single-phase or three-phase.

2. Calculate Total Turns

Calculating the total number of turns involves understanding the specific design requirements of the motor, such as efficiency, power factor, and maximum current. The total number of turns can be estimated using the following empirical formula:

987b2d8e8b2a928be2a9107cf8366484.jpeg

Where:


  • k is an empirical coefficient that depends on the specific design of the motor.

  • U is the rated voltage of the motor.

  • ϕ is the phase angle, typically  3 for a three-phase motor.


  • Bm is the maximum flux density in the air gap of the motor.

3. Allocate Turns Per Slot

Once the total number of turns is determined, it can be distributed among each slot. For a three-phase motor, the number of turns in each phase winding should be the same, and the number of turns per slot should be evenly distributed to ensure balance. The number of turns per slot can be calculated using the following formula:

ff8d86e2f665f7b831731734d53c71ef.jpeg

Where:

  • Nslot is the number of turns per slot.

  • Z is the total number of slots.

Example Calculation

Assume a three-phase induction motor with the following parameters:

  • Rated Voltage U=400 V

  • Number of Pole p=2 (four-pole motor)

  • Number of Slots Z=36

  • Rated Frequency f=50 Hz

  • Maximum Flux Density Bm=1.5 T

Assuming the empirical coefficient
k=0.05:

373f91f62f50cbb72bb77253690eea16.jpeg

Assuming the total number of turns is 47, distributed among 36 slots:

373f91f62f50cbb72bb77253690eea16.jpeg

Since the actual winding design typically requires the number of turns per slot to be an integer, the total number of turns may need to be adjusted to allow for an even distribution among the slots.

Notes

  • Actual Design: In actual motor designs, the number of turns per slot may need to be adjusted based on the specific requirements and manufacturing processes of the motor.

  • Winding Type: Different types of windings (such as concentrated windings or distributed windings) may affect the calculation of the number of turns per slot.

  • Empirical Data: The empirical coefficient 
    k in the formula may need to be adjusted based on the specific type and design requirements of the motor.

By following these steps, you can roughly calculate the number of turns per slot in a single-phase or three-phase induction motor. However, actual motor design often requires specialized motor design software and extensive practical experience to optimize the winding design.


Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!