Why is a phase induction motor not self-starting?

Encyclopedia
11/05/2024

Actually, a three-phase induction motor can self-start, but there might be some confusion here. While a three-phase induction motor can self-start under normal conditions, a single-phase induction motor cannot self-start. To clarify this, let's examine the starting mechanisms of both three-phase and single-phase induction motors.

Self-Starting Capability of a Three-Phase Induction Motor

1. Generation of Rotating Magnetic Field

A three-phase induction motor can self-start because it can generate a rotating magnetic field. Here is the specific mechanism:

Three-Phase Power Supply: A three-phase induction motor typically uses a three-phase AC power supply. The three-phase power consists of three sine waves that are 120 degrees out of phase with each other.

Stator Windings: The stator contains three sets of windings, each corresponding to one phase. These windings are spaced 120 degrees apart in space, uniformly distributed around the inner wall of the stator.

Current Flow: When the three-phase power is applied to the stator windings, each winding carries a corresponding alternating current. These currents are 120 degrees out of phase, creating a rotating magnetic field in both time and space.

2. Effect of Rotating Magnetic Field

Induced Current in Rotor: The rotating magnetic field induces currents in the rotor, generating a rotor magnetic field.

Electromagnetic Torque: The interaction between the rotor magnetic field and the stator magnetic field produces electromagnetic torque, causing the rotor to begin rotating.

Self-Starting Problem of a Single-Phase Induction Motor

A single-phase induction motor cannot self-start because it cannot generate a rotating magnetic field. Here is the specific mechanism:

1. Characteristics of Single-Phase Power Supply

Single-Phase Power Supply: A single-phase induction motor uses a single-phase AC power supply. The single-phase power consists of a single sine wave.

Stator Windings: The stator typically contains two windings, one main winding and one auxiliary winding.

2. Generation of Magnetic Field

Pulsating Magnetic Field: The single-phase power generates a pulsating magnetic field in the stator windings, rather than a rotating magnetic field. This means the direction of the magnetic field does not change but instead fluctuates periodically.

Lack of Rotating Magnetic Field: Due to the lack of a rotating magnetic field, the induced currents in the rotor do not produce sufficient torque to start the rotor rotating.

3. Solutions

To enable a single-phase induction motor to self-start, the following methods are typically used:

Capacitor Start: During startup, a capacitor is used to provide a phase shift to the auxiliary winding, creating an approximate rotating magnetic field. Once the motor reaches a certain speed, the auxiliary winding is disconnected.

Capacitor Run: During operation, a capacitor provides a phase shift to the auxiliary winding, continuously producing a rotating magnetic field.

Permanent Split Capacitor (PSC): Using a permanent split capacitor, the auxiliary winding remains connected throughout operation, providing a continuous rotating magnetic field.

Summary

Three-Phase Induction Motor: Can self-start because the three-phase power supply can generate a rotating magnetic field in the stator, causing the rotor to begin rotating.

Single-Phase Induction Motor: Cannot self-start because the single-phase power supply can only generate a pulsating magnetic field, not a rotating magnetic field. Methods such as capacitor start or permanent split capacitor are needed to generate a rotating magnetic field and enable self-starting.

We hope the above explanation helps you understand the starting mechanisms of three-phase and single-phase induction motors.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!