Split Phase Induction Motor

Encyclopedia
04/23/2025

The Split Phase Motor, alternatively referred to as a Resistance Start Motor, features a single - cage rotor. Its stator is equipped with two distinct windings: the main winding and the starting winding. These two windings are spatially displaced by 90 degrees, a configuration that plays a crucial role in the motor's operation.

The main winding is characterized by its very low resistance and high inductive reactance, while the starting winding exhibits the opposite characteristics, with high resistance and low inductive reactance. This disparity in electrical properties between the two windings is key to generating the necessary torque for starting the motor. The connection diagram of this motor is presented below, illustrating how these components interact within the electrical circuit:

image.png

A resistor is connected in series with the auxiliary (starting) winding. Due to this arrangement, the currents flowing through the two windings differ. Consequently, the resulting rotating magnetic field is non - uniform, leading to a relatively small starting torque. Typically, this starting torque is in the range of 1.5 to 2 times the specified running torque. At the moment of starting, both the main and starting windings are connected in parallel across the power supply.

Once the motor accelerates to approximately 70 - 80% of the synchronous speed, the starting winding is automatically disconnected from the power source. For motors with a rating of around 100 Watts or higher, a centrifugal switch is commonly employed to perform this disconnection. In contrast, for lower - rated motors, a relay serves the purpose of disconnecting the starting winding.

A relay is connected in series with the main winding. During the starting phase, a significant amount of current surges through the circuit, which causes the relay contacts to close. This action places the starting winding into the circuit. As the motor approaches its predetermined operating speed, the current flowing through the relay begins to decline. Eventually, the relay opens, severing the connection of the auxiliary winding from the power supply. At this point, the motor continues to operate solely on the main winding.

The phasor diagram of the Split Phase Induction Motor, which elucidates the electrical relationships and phase differences within the motor, is depicted below:

image.png

The current in the main winding, denoted as IM, lags behind the supply voltage V by nearly 90 degrees. In contrast, the current in the auxiliary winding, IA, is approximately in phase with the line voltage. This disparity in the phase relationship between the two windings results in a time difference between their currents. While the time phase difference ϕ is not a full 90 degrees, typically around 30 degrees, it is sufficient to generate a rotating magnetic field. This rotating magnetic field is crucial for initiating the motor's rotation and enabling it to operate.

The Torque - Speed Characteristic of the Split Phase motor, which illustrates how the torque output of the motor varies with its rotational speed, is presented below. This characteristic curve provides valuable insights into the motor's performance under different operating conditions and is essential for understanding its behavior and optimizing its use in various applications.

image.png

In the torque - speed characteristic of the Split Phase motor, n0 marks the rotational speed at which the centrifugal switch activates. The starting torque of the resistance - start motor typically measures around 1.5 times its full - load torque. At approximately 75% of the synchronous speed, the motor can achieve a maximum torque that is roughly 2.5 times the full - load torque. However, it's important to note that during starting, the motor draws a substantial current, amounting to about 7 to 8 times the full - load value.

Reversing the direction of a Resistance Start motor is a straightforward process. It can be accomplished by simply reversing the line connection of either the main winding or the starting winding. It's crucial to emphasize that this reversal can only be carried out when the motor is at a standstill; attempting to reverse it while in motion can lead to mechanical and electrical damage.

Applications of Split Phase Induction Motor

Split Phase Induction Motors are renowned for their affordability. They are well - suited for applications involving loads that are easy to start, especially when the frequency of starting operations is relatively low. Due to their limited starting torque, these motors are not ideal for drives requiring more than 1 KW of power. Nevertheless, they find extensive use in a wide range of common household and industrial appliances:

  • Home Appliances: They power components such as washing machines and air - conditioning fans, facilitating the smooth operation of these essential devices.

  • Kitchen and Cleaning Equipment: In the kitchen, they drive mixer grinders, while in cleaning applications, they are used in floor polishers, making daily chores more convenient.

  • Fluid Handling and Ventilation: Blowers and centrifugal pumps, which are vital for ventilation and fluid transportation in various systems, often rely on Split Phase Induction Motors for their operation.

  • Machining Tools: These motors also play a role in drilling and lathe machines, contributing to the precision and efficiency of machining processes.

In summary, the Split Phase Induction Motor, with its distinct characteristics and practical applications, remains a valuable component in the world of electrical engineering.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!